Schneider Electric · Energy meter
PowerLogic PM2000 series (PM2100 / PM2200, incl. EM6400 NG) Modbus register map
Default configuration
- Protocol
- RS485
- Port
- 502
- Unit ID
- 1
- Addressing
- 0-based
- Byte order
- Big endian
- Word order
- High word first
- Baud rate
- 19200
- Parity
- Even
- Data bits
- 8
- Stop bits
- 1
This device has an RS-485 interface. Reach it through a Modbus RTU-to-TCP gateway, configured with the factory serial settings above.
Register map
| Address | Count | Name | Type | Unit | Scale | Access |
|---|---|---|---|---|---|---|
| 30 | 20 | Meter Name | Ascii | - | 1 | RW |
| 50 | 20 | Meter Model | Ascii | - | 1 | RW |
| 70 | 20 | Manufacturer | Ascii | - | 1 | RW |
| 90 | 1 | Product ID Number | UInt16 | - | 1 | RW |
| 129 | 1 | Manufacturing Unit Id (To be prefixed in Serial Number While Displaying) | UInt16 | - | 1 | R |
| 130 | 2 | Serial Number | UInt32 | - | 1 | R |
| 136 | 5 | Hardware Revision | Ascii | - | 1 | R |
| 141 | 1 | Production History 01 | UInt16 | - | 1 | R |
| 142 | 1 | Production History 02 | UInt16 | - | 1 | R |
| 143 | 1 | Production History 03 | UInt16 | - | 1 | R |
| 144 | 1 | Production History 04 | UInt16 | - | 1 | R |
| 145 | 1 | Production History 05 | UInt16 | - | 1 | R |
| 146 | 1 | Production History 06 | UInt16 | - | 1 | R |
| 147 | 1 | Production History 07 | UInt16 | - | 1 | R |
| 148 | 1 | Production History 08 | UInt16 | - | 1 | R |
| 149 | 1 | Production History 09 | UInt16 | - | 1 | R |
| 150 | 1 | Production History 10 | UInt16 | - | 1 | R |
| 151 | 1 | Production History 11 | UInt16 | - | 1 | R |
| 152 | 1 | Production History 12 | UInt16 | - | 1 | R |
| 153 | 1 | Production History 13 | UInt16 | - | 1 | R |
| 154 | 1 | Production History 14 | UInt16 | - | 1 | R |
| 155 | 1 | Production History 15 | UInt16 | - | 1 | R |
| 156 | 1 | Production History 16 | UInt16 | - | 1 | R |
| 157 | 1 | Production History 17 | UInt16 | - | 1 | R |
| 158 | 1 | Production History 18 | UInt16 | - | 1 | R |
| 159 | 1 | Production History 19 | UInt16 | - | 1 | R |
| 160 | 1 | Production History 20 | UInt16 | - | 1 | R |
| 161 | 1 | Checksum | UInt16 | - | 1 | R |
| 400 | 1 | Installed Option – Slot A | UInt16 | - | 1 | R |
| 403 | 2 | Serial Number | UInt32 | - | 1 | R |
| 409 | 5 | Hardware Revision | Ascii | - | 1 | R |
| 414 | 1 | FW version | UInt16 | - | 1 | R |
| 436 | 1 | Installed Option – Slot B | UInt16 | - | 1 | R |
| 445 | 1 | Hardware Revision | UInt16 | - | 1 | R |
| 1637 | 1 | Present Firmware Version (DLF Format) X.Y.T | UInt16 | - | 1 | R |
| 1638 | 1 | X – Major | UInt16 | - | 1 | R |
| 1639 | 1 | Y – Minor | UInt16 | - | 1 | R |
| 1640 | 1 | Z – Quality | UInt16 | - | 1 | R |
| 1641 | 1 | T – Internal evolutions | UInt16 | - | 1 | R |
| 1642 | 1 | Previous Firmware Version (DLF Format) X.Y.T | UInt16 | - | 1 | R |
| 1643 | 1 | X – Major | UInt16 | - | 1 | R |
| 1644 | 1 | Y – Minor | UInt16 | - | 1 | R |
| 1645 | 1 | Z – Quality | UInt16 | - | 1 | R |
| 1646 | 1 | T – Internal evolutions | UInt16 | - | 1 | R |
| 1669 | 1 | Present Firmware Version (DLF Format) X.Y.T | UInt16 | - | 1 | R |
| 1670 | 1 | X – Major | UInt16 | - | 1 | R |
| 1671 | 1 | Y – Minor | UInt16 | - | 1 | R |
| 1672 | 1 | Z – Quality | UInt16 | - | 1 | R |
| 1673 | 1 | T – Internal evolutions | UInt16 | - | 1 | R |
| 1674 | 1 | Previous Firmware Version (DLF Format) X.Y.T | UInt16 | - | 1 | R |
| 1675 | 1 | X – Major | UInt16 | - | 1 | R |
| 1676 | 1 | Y – Minor | UInt16 | - | 1 | R |
| 1677 | 1 | Z – Quality | UInt16 | - | 1 | R |
| 1678 | 1 | T – Internal evolutions | UInt16 | - | 1 | R |
| 1701 | 1 | Present Firmware Version (DLF Format) X.Y.T | UInt16 | - | 1 | R |
| 1702 | 1 | X – Major | UInt16 | - | 1 | R |
| 1703 | 1 | Y – Minor | UInt16 | - | 1 | R |
| 1704 | 1 | Z – Quality | UInt16 | - | 1 | R |
| 1705 | 1 | T – Internal evolutions | UInt16 | - | 1 | R |
| 1706 | 1 | Previous Firmware Version (DLF Format) X.Y.T | UInt16 | - | 1 | R |
| 1707 | 1 | X – Major | UInt16 | - | 1 | R |
| 1708 | 1 | Y – Minor | UInt16 | - | 1 | R |
| 1709 | 1 | Z – Quality | UInt16 | - | 1 | R |
| 1710 | 1 | T – Internal evolutions | UInt16 | - | 1 | R |
| 1715 | 1 | Checksum | UInt16 | - | 1 | R |
| 1716 | 1 | Bridge Code Version | UInt16 | - | 1 | R |
| 1747 | 1 | Download – CRC of Last FW Download | UInt16 | - | 1 | R |
| 1748 | 1 | Download – Flash Write Failure | UInt16 | - | 1 | R |
| 1749 | 1 | Download – % Complete | UInt16 | - | 1 | R |
| 1750 | 1 | Reserved For Download Software Use | UInt16 | - | 1 | RW |
| 1828 | 1 | Number of Metering System Restarts | UInt16 | - | 1 | R |
| 1829 | 1 | Number of Control Power Failures | UInt16 | - | 1 | R |
| 1834 | 2 | Duration of Last Control Power Failure | UInt32 | seconds | 1 | R |
| 1836 | 1 | Cause of Last Meter Reset | UInt16 | - | 1 | R |
| 1837 | 1 | Year | UInt16 | year | 1 | R |
| 1838 | 1 | Month | UInt16 | month | 1 | R |
| 1839 | 1 | Day | UInt16 | days | 1 | R |
| 1840 | 1 | Hour | UInt16 | hours | 1 | R |
| 1841 | 1 | Minute | UInt16 | minutes | 1 | R |
| 1842 | 1 | Second | UInt16 | seconds | 1 | R |
| 1843 | 1 | Millisecond | UInt16 | msec | 1 | R |
| 1844 | 1 | Day of Week | UInt16 | - | 1 | R |
| 1845 | 1 | Year | UInt16 | - | 1 | R |
| 1846 | 1 | Month & Day | UInt16 | - | 1 | R |
| 1847 | 1 | Hour & Minute | UInt16 | - | 1 | R |
| 1848 | 1 | Milliseconds | UInt16 | - | 1 | R |
| 1880 | 4 | Setup Password | Ascii | - | 1 | RW |
| 1884 | 4 | Energy Reset Password | Ascii | - | 1 | RW |
| 1888 | 4 | Demand Reset Password | Ascii | - | 1 | RW |
| 1892 | 4 | Min/Max Reset Password | Ascii | - | 1 | RW |
| 1896 | 4 | Diagnostics Password | Ascii | - | 1 | RW |
| 2002 | 2 | Active Load Timer | UInt32 | seconds | 1 | R |
| 2004 | 2 | Meter Operation Timer | UInt32 | seconds | 1 | R |
| 2006 | 2 | Cycle Count | UInt32 | - | 1 | R |
| 2014 | 1 | Number of Phases | UInt16 | - | 1 | RW |
| 2015 | 1 | Number of Wires | UInt16 | - | 1 | RW |
| 2016 | 1 | Power System Configuration | UInt16 | - | 1 | RW |
| 2017 | 1 | Nominal Frequency | UInt16 | Hz | 1 | RW |
| 2018 | 2 | Nominal Voltage | Float32 | V | 1 | RW |
| 2020 | 2 | Nominal Current | Float32 | A | 1 | RW |
| 2024 | 1 | Normal Phase Rotation | UInt16 | - | 1 | RW |
| 2025 | 1 | Number VTs | UInt16 | - | 1 | RW |
| 2026 | 2 | VT Primary | Float32 | V | 1 | RW |
| 2028 | 1 | VT Secondary | UInt16 | V | 1 | RW |
| 2029 | 1 | Number CTs | UInt16 | - | 1 | RW |
| 2030 | 1 | CT Primary | UInt16 | A | 1 | RW |
| 2031 | 1 | CT Secondary | UInt16 | A | 1 | RW |
| 2032 | 1 | CT Primary N | UInt16 | A | 1 | RW |
| 2033 | 1 | CT Secondary N | UInt16 | A | 1 | RW |
| 2034 | 1 | CT Location for 1 or 2 CT Metering | UInt16 | - | 1 | RW |
| 2035 | 1 | VT Location for 1 or 2 VT Metering | UInt16 | - | 1 | RW |
| 2036 | 1 | VT Connection Type | UInt16 | - | 1 | RW |
| 2050 | 2 | Active Load Timer Setpoint | Float32 | A | 1 | RW |
| 2126 | 1 | Alarm / Energy LED Mode | UInt16 | - | 1 | RW |
| 2128 | 1 | Energy Output Pulse Mode (Pulse/KY) / make per chan | UInt16 | - | 1 | RW |
| 2129 | 1 | Energy Pulse Duration | UInt16 | msec | 1 | RW |
| 2130 | 1 | Energy Channel | UInt16 | - | 1 | RW |
| 2131 | 1 | Digital Output Association | UInt16 | - | 1 | RW |
| 2132 | 2 | Pulse Weight | UInt32 | kWh, kVAh, kVAh | 1 | RW |
| 2134 | 1 | Energy Channel | UInt16 | - | 1 | RW |
| 2135 | 1 | Digital Output Association | UInt16 | - | 1 | RW |
| 2136 | 2 | Pulse Weight | UInt32 | kWh, kVAh, kVAh | 1 | RW |
| 2138 | 1 | Energy Channel | UInt16 | - | 1 | RW |
| 2139 | 1 | Digital Output Association | UInt16 | - | 1 | RW |
| 2140 | 2 | Pulse Weight | UInt32 | kWh, kVAh, kVAh | 1 | RW |
| 2244 | 20 | Label | Ascii | - | 1 | RW |
| 2264 | 1 | Energy Channel | UInt16 | - | 1 | RW |
| 2265 | 2 | Factor per k__h | Float32 | - | 1 | RW |
| 2267 | 20 | Label | Ascii | - | 1 | RW |
| 2287 | 1 | Energy Channel | UInt16 | - | 1 | RW |
| 2288 | 2 | Factor per k__h | Float32 | - | 1 | RW |
| 2292 | 1 | Energy Overflow Scale selection | UInt16 | - | 1 | RW |
| 2302 | 1 | CT Sequence Selection | UInt16 | - | 1 | RW |
| 2303 | 1 | CT Reverse | UInt16 | - | 1 | RW |
| 2420 | 1 | Standard - 1 second Group 1 Validity | Hex | - | 1 | R |
| 2421 | 1 | Standard - 1 second Group 1 | Hex | - | 1 | R |
| 2422 | 1 | Standard - 1 second Group 2 Validity | Hex | - | 1 | R |
| 2423 | 1 | Standard - 1 second Group 2 | Hex | - | 1 | R |
| 2424 | 1 | Standard - 1 second Group 3 Validity | Hex | - | 1 | R |
| 2425 | 1 | Standard - 1 second Group 3 | Hex | - | 1 | R |
| 2440 | 1 | Unary Validity | Hex | - | 1 | R |
| 2441 | 1 | Unary | Hex | - | 1 | R |
| 2442 | 1 | Digital Group 1 Validity | Hex | - | 1 | R |
| 2443 | 1 | Digital Group 1 | Hex | - | 1 | R |
| 2550 | 1 | Digital Input Status Validity – Option Slot A | Hex | - | 1 | R |
| 2551 | 1 | Digital Input Status – Option Slot A | Hex | - | 1 | R |
| 2566 | 1 | Digital Output Status Validity – Option Slot A | Hex | - | 1 | R |
| 2567 | 1 | Digital Output Status – Option Slot A | Hex | - | 1 | R |
| 2568 | 1 | Digital Output Status Validity – Option Slot B | Hex | - | 1 | R |
| 2569 | 1 | Digital Output Status – Option Slot B | Hex | - | 1 | R |
| 2676 | 2 | Active Energy Delivered (Into Load) | Float32 | kWh | 1 | R |
| 2678 | 2 | Active Energy Received (Out of Load) | Float32 | kWh | 1 | R |
| 2680 | 2 | Active Energy Delivered + Received | Float32 | kWh | 1 | R |
| 2682 | 2 | Active Energy Delivered- Received | Float32 | kWh | 1 | R |
| 2684 | 2 | Reactive Energy Delivered | Float32 | kVARh | 1 | R |
| 2686 | 2 | Reactive Energy Received | Float32 | kVARh | 1 | R |
| 2688 | 2 | Reactive Energy Delivered + Received | Float32 | kVARh | 1 | R |
| 2690 | 2 | Reactive Energy Delivered - Received | Float32 | kVARh | 1 | R |
| 2692 | 2 | Apparent Energy Delivered | Float32 | kVAh | 1 | R |
| 2694 | 2 | Apparent Energy Received | Float32 | kVAh | 1 | R |
| 2696 | 2 | Apparent Energy Delivered + Received | Float32 | kVAh | 1 | R |
| 2698 | 2 | Apparent Energy Delivered - Received | Float32 | kVAh | 1 | R |
| 2700 | 2 | Active Energy Delivered (Into Load) | Float32 | kWh | 1 | R |
| 2702 | 2 | Active Energy Received (Out of Load) | Float32 | kWh | 1 | R |
| 2704 | 2 | Active Energy Delivered + Received | Float32 | kWh | 1 | R |
| 2706 | 2 | Active Energy Delivered- Received | Float32 | kWh | 1 | R |
| 2708 | 2 | Reactive Energy Delivered | Float32 | kVARh | 1 | R |
| 2710 | 2 | Reactive Energy Received | Float32 | kVARh | 1 | R |
| 2712 | 2 | Reactive Energy Delivered + Received | Float32 | kVARh | 1 | R |
| 2714 | 2 | Reactive Energy Delivered - Received | Float32 | kVARh | 1 | R |
| 2716 | 2 | Apparent Energy Delivered | Float32 | kVAh | 1 | R |
| 2718 | 2 | Apparent Energy Received | Float32 | kVAh | 1 | R |
| 2720 | 2 | Apparent Energy Delivered + Received | Float32 | kVAh | 1 | R |
| 2722 | 2 | Apparent Energy Delivered - Received | Float32 | kVAh | 1 | R |
| 2732 | 2 | Reactive Energy in Quadrant I | Float32 | kVARh | 1 | R |
| 2734 | 2 | Reactive Energy in Quadrant II | Float32 | kVARh | 1 | R |
| 2738 | 2 | Reactive Energy in Quadrant III | Float32 | kVARh | 1 | R |
| 2740 | 2 | Reactive Energy in Quadrant IV | Float32 | kVARh | 1 | R |
| 2812 | 2 | Active Energy Delivered Phase A | Float32 | kWh | 1 | R |
| 2814 | 2 | Active Energy Delivered Phase B | Float32 | kWh | 1 | R |
| 2816 | 2 | Active Energy Delivered Phase C | Float32 | kWh | 1 | R |
| 2818 | 2 | Reactive Energy Delivered Phase A | Float32 | kVARh | 1 | R |
| 2820 | 2 | Reactive Energy Delivered Phase B | Float32 | kVARh | 1 | R |
| 2822 | 2 | Reactive Energy Delivered Phase C | Float32 | kVARh | 1 | R |
| 2824 | 2 | Apparent Energy Delivered Phase A | Float32 | kVAh | 1 | R |
| 2826 | 2 | Apparent Energy Delivered Phase B | Float32 | kVAh | 1 | R |
| 2828 | 2 | Apparent Energy Delivered Phase C | Float32 | kVAh | 1 | R |
| 2854 | 2 | Rate1 value | Float32 | - | 1 | R |
| 2856 | 2 | Rate 2 Value | Float32 | - | 1 | R |
| 3000 | 2 | Current A | Float32 | A | 1 | R |
| 3002 | 2 | Current B | Float32 | A | 1 | R |
| 3004 | 2 | Current C | Float32 | A | 1 | R |
| 3006 | 2 | Current N | Float32 | A | 1 | R |
| 3008 | 2 | Current G | Float32 | A | 1 | R |
| 3010 | 2 | Current Avg | Float32 | A | 1 | R |
| 3012 | 2 | Current Unbalance A | Float32 | % | 1 | R |
| 3014 | 2 | Current Unbalance B | Float32 | % | 1 | R |
| 3016 | 2 | Current Unbalance C | Float32 | % | 1 | R |
| 3018 | 2 | Current Unbalance Worst | Float32 | % | 1 | R |
| 3020 | 2 | Voltage A-B | Float32 | V | 1 | R |
| 3022 | 2 | Voltage B-C | Float32 | V | 1 | R |
| 3024 | 2 | Voltage C-A | Float32 | V | 1 | R |
| 3026 | 2 | Voltage L-L Avg | Float32 | V | 1 | R |
| 3028 | 2 | Voltage A-N | Float32 | V | 1 | R |
| 3030 | 2 | Voltage B-N | Float32 | V | 1 | R |
| 3032 | 2 | Voltage C-N | Float32 | V | 1 | R |
| 3036 | 2 | Voltage L-N Avg | Float32 | V | 1 | R |
| 3038 | 2 | Voltage Unbalance A-B | Float32 | % | 1 | R |
| 3040 | 2 | Voltage Unbalance B-C | Float32 | % | 1 | R |
| 3042 | 2 | Voltage Unbalance C-A | Float32 | % | 1 | R |
| 3044 | 2 | Voltage Unbalance L-L Worst | Float32 | % | 1 | R |
| 3046 | 2 | Voltage Unbalance A-N | Float32 | % | 1 | R |
| 3048 | 2 | Voltage Unbalance B-N | Float32 | % | 1 | R |
| 3050 | 2 | Voltage Unbalance C-N | Float32 | % | 1 | R |
| 3052 | 2 | Voltage Unbalance L-N Worst | Float32 | % | 1 | R |
| 3054 | 2 | Active Power A | Float32 | kW | 1 | R |
| 3056 | 2 | Active Power B | Float32 | kW | 1 | R |
| 3058 | 2 | Active Power C | Float32 | kW | 1 | R |
| 3060 | 2 | Active Power Total | Float32 | kW | 1 | R |
| 3062 | 2 | Reactive Power A | Float32 | kVAR | 1 | R |
| 3064 | 2 | Reactive Power B | Float32 | kVAR | 1 | R |
| 3066 | 2 | Reactive Power C | Float32 | kVAR | 1 | R |
| 3068 | 2 | Reactive Power Total | Float32 | kVAR | 1 | R |
| 3070 | 2 | Apparent Power A | Float32 | kVA | 1 | R |
| 3072 | 2 | Apparent Power B | Float32 | kVA | 1 | R |
| 3074 | 2 | Apparent Power C | Float32 | kVA | 1 | R |
| 3076 | 2 | Apparent Power Total | Float32 | kVA | 1 | R |
| 3110 | 2 | Frequency | Float32 | Hz | 1 | R |
| 3192 | 2 | Power Factor Total | Float32 | - | 1 | R |
| 3194 | 2 | Power Factor Total | Float32 | - | 1 | R |
| 3196 | 1 | Power Factor Total | Int16 | - | 1 | R |
| 3197 | 1 | Power Factor Total | Int16 | - | 1 | R |
| 3701 | 1 | Power Demand Method | UInt16 | - | 1 | RW |
| 3702 | 1 | Power Demand Interval Duration | UInt16 | minutes | 1 | RW |
| 3703 | 1 | Power Demand Subinterval Duration | UInt16 | minutes | 1 | RW |
| 3704 | 1 | Power Demand Elapsed Time in Interval | UInt16 | seconds | 1 | R |
| 3705 | 1 | Power Demand Elapsed Time in Subinterval | UInt16 | seconds | 1 | R |
| 3711 | 1 | Current Demand Method | UInt16 | - | 1 | RW |
| 3712 | 1 | Current Demand Interval Duration | UInt16 | minutes | 1 | RW |
| 3713 | 1 | Current Demand Subinterval Duration | UInt16 | minutes | 1 | RW |
| 3714 | 1 | Current Demand Elapsed Time in Interval | UInt16 | seconds | 1 | R |
| 3715 | 1 | Current Demand Elapsed Time in Subinterval | UInt16 | seconds | 1 | R |
| 3761 | 1 | Demand System Assignment | UInt16 | - | 1 | R |
| 3762 | 1 | Register Number of Metered Quantity | UInt16 | - | 1 | R |
| 3763 | 1 | Units Code | UInt16 | - | 1 | R |
| 3764 | 2 | Last Demand | Float32 | kW | 1 | R |
| 3766 | 2 | Present Demand | Float32 | kW | 1 | R |
| 3768 | 2 | Predicted Demand | Float32 | kW | 1 | R |
| 3770 | 2 | Peak Demand | Float32 | kW | 1 | R |
| 3777 | 1 | Demand System Assignment | UInt16 | - | 1 | R |
| 3778 | 1 | Register Number of Metered Quantity | UInt16 | - | 1 | R |
| 3779 | 1 | Units Code | UInt16 | - | 1 | R |
| 3780 | 2 | Last Demand | Float32 | kVAR | 1 | R |
| 3782 | 2 | Present Demand | Float32 | kVAR | 1 | R |
| 3784 | 2 | Predicted Demand | Float32 | kVAR | 1 | R |
| 3786 | 2 | Peak Demand | Float32 | kVAR | 1 | R |
| 3793 | 1 | Demand System Assignment | UInt16 | - | 1 | R |
| 3794 | 1 | Register Number of Metered Quantity | UInt16 | - | 1 | R |
| 3795 | 1 | Units Code | UInt16 | - | 1 | R |
| 3796 | 2 | Last Demand | Float32 | kVA | 1 | R |
| 3798 | 2 | Present Demand | Float32 | kVA | 1 | R |
| 3800 | 2 | Predicted Demand | Float32 | kVA | 1 | R |
| 3802 | 2 | Peak Demand | Float32 | kVA | 1 | R |
| 3873 | 1 | Demand System Assignment | UInt16 | - | 1 | R |
| 3874 | 1 | Register Number of Metered Quantity | UInt16 | - | 1 | R |
| 3875 | 1 | Units Code | UInt16 | - | 1 | R |
| 3876 | 2 | Last Demand | Float32 | A | 1 | R |
| 3878 | 2 | Present Demand | Float32 | A | 1 | R |
| 3880 | 2 | Predicted Demand | Float32 | A | 1 | R |
| 3882 | 2 | Peak Demand | Float32 | A | 1 | R |
| 4190 | 1 | TOU/MT Mode | UInt16 | - | 1 | RW |
| 4191 | 1 | TOU/MT Energy Active Rate | UInt16 | - | 1 | R |
| 4516 | 1 | MT Day Type Rate 1 | UInt16 | - | 1 | RW |
| 4517 | 1 | MT Start Time Rate 1 | UInt16 | - | 1 | RW |
| 4518 | 1 | MT End Time Rate 1 | UInt16 | - | 1 | RW |
| 4519 | 1 | MT Start Month Rate1 | UInt16 | - | 1 | RW |
| 4520 | 1 | MT Start Day Rate 1 | UInt16 | - | 1 | RW |
| 4521 | 1 | MT End Month Rate 1 | UInt16 | - | 1 | RW |
| 4522 | 1 | MT End Day Rate 1 | UInt16 | - | 1 | RW |
| 4523 | 1 | MT Day Type Rate 2 | UInt16 | - | 1 | RW |
| 4524 | 1 | MT Start Time Rate 2 | UInt16 | - | 1 | RW |
| 4525 | 1 | MT End Time Rate 2 | UInt16 | - | 1 | RW |
| 4526 | 1 | MT Start Month Rate2 | UInt16 | - | 1 | RW |
| 4527 | 1 | MT Start Day Rate 2 | UInt16 | - | 1 | RW |
| 4528 | 1 | MT End Month Rate 2 | UInt16 | - | 1 | RW |
| 4529 | 1 | MT End Day Rate 2 | UInt16 | - | 1 | RW |
| 4530 | 1 | MT Day Type Rate 3 | UInt16 | - | 1 | RW |
| 4531 | 1 | MT Start Time Rate 3 | UInt16 | - | 1 | RW |
| 4532 | 1 | MT End Time Rate 3 | UInt16 | - | 1 | RW |
| 4533 | 1 | MT Start Month Rate3 | UInt16 | - | 1 | RW |
| 4534 | 1 | MT Start Day Rate 3 | UInt16 | - | 1 | RW |
| 4535 | 1 | MT End Month Rate 3 | UInt16 | - | 1 | RW |
| 4536 | 1 | MT End Day Rate 3 | UInt16 | - | 1 | RW |
| 4537 | 1 | MT Day Type Rate 4 | UInt16 | - | 1 | RW |
| 4538 | 1 | MT Start Time Rate 4 | UInt16 | - | 1 | RW |
| 4539 | 1 | MT End Time Rate 4 | UInt16 | - | 1 | RW |
| 4540 | 1 | MT Start Month Rate4 | UInt16 | - | 1 | RW |
| 4541 | 1 | MT Start Day Rate 4 | UInt16 | - | 1 | RW |
| 4542 | 1 | MT End Month Rate 4 | UInt16 | - | 1 | RW |
| 4543 | 1 | MT End Day Rate 4 | UInt16 | - | 1 | RW |
| 6500 | 1 | RS-485 Comm Port (M/S) Protocol | UInt16 | - | 1 | RW |
| 6501 | 1 | RS-485 Comm Port (M/S) Address | UInt16 | - | 1 | RW |
| 6502 | 1 | RS-485 Comm Port (M/S) Baud Rate | UInt16 | - | 1 | RW |
| 6503 | 1 | RS-485 Comm Port (M/S) Parity | UInt16 | - | 1 | RW |
| 7012 | 1 | Number of Multi-tariff Rates Active | UInt16 | - | 1 | RW |
| 7013 | 1 | Number of Digital Inputs Used to Control Multi-tariff | UInt16 | - | 1 | RW |
| 7417 | 1 | Type | UInt16 | - | 1 | R |
| 7418 | 1 | Control Mode | UInt16 | - | 1 | RW |
| 7419 | 20 | Label | Ascii | - | 1 | RW |
| 7439 | 1 | Debounce Time | UInt16 | msec | 1 | RW |
| 7441 | 1 | Type | UInt16 | - | 1 | R |
| 7442 | 1 | Control Mode | UInt16 | - | 1 | RW |
| 7443 | 20 | Label | Ascii | - | 1 | RW |
| 7463 | 1 | Debounce Time | UInt16 | msec | 1 | RW |
| 8939 | 2 | Count | UInt32 | - | 1 | R |
| 8941 | 2 | On Time | UInt32 | seconds | 1 | R |
| 8943 | 2 | Count | UInt32 | - | 1 | R |
| 8945 | 2 | On Time | UInt32 | seconds | 1 | R |
| 9283 | 1 | Type | UInt16 | - | 1 | R |
| 9284 | 20 | Label | Ascii | - | 1 | RW |
| 9304 | 1 | Enable/Disable | UInt16 | - | 1 | RW |
| 9305 | 1 | Behavioral Mode | UInt16 | - | 1 | RW |
| 9306 | 1 | On Time For Timed Mode | UInt16 | seconds | 1 | RW |
| 9307 | 1 | Type | UInt16 | - | 1 | R |
| 9308 | 20 | Label | Ascii | - | 1 | RW |
| 9328 | 1 | Enable/Disable | UInt16 | - | 1 | RW |
| 9329 | 1 | Behavioral Mode | UInt16 | - | 1 | RW |
| 9330 | 1 | On Time For Timed Mode | UInt16 | seconds | 1 | RW |
| 9331 | 1 | Type | UInt16 | - | 1 | R |
| 9332 | 20 | Label | Ascii | - | 1 | RW |
| 9352 | 1 | Enable/Disable | UInt16 | - | 1 | RW |
| 9353 | 1 | Behavioral Mode | UInt16 | - | 1 | RW |
| 9354 | 1 | On Time For Timed Mode | UInt16 | seconds | 1 | RW |
| 9355 | 1 | Type | UInt16 | - | 1 | R |
| 9356 | 20 | Label | Ascii | - | 1 | RW |
| 9376 | 1 | Enable/Disable | UInt16 | - | 1 | RW |
| 9377 | 1 | Behavioral Mode | UInt16 | - | 1 | RW |
| 9378 | 1 | On Time For Timed Mode | UInt16 | seconds | 1 | RW |
| 9650 | 1 | DO Default State | UInt16 | - | 1 | RW |
| 9704 | 1 | Operating Mode Status | UInt16 | - | 1 | R |
| 9705 | 1 | Control Mode Status | UInt16 | - | 1 | R |
| 9706 | 1 | Behavioral Mode Status | UInt16 | - | 1 | R |
| 9707 | 2 | Count | UInt32 | - | 1 | R |
| 9709 | 2 | On Time | UInt32 | seconds | 1 | R |
| 9711 | 1 | Reserved | UInt16 | - | 1 | R |
| 9712 | 1 | Operating Mode Status | UInt16 | - | 1 | R |
| 9713 | 1 | Control Mode Status | UInt16 | - | 1 | R |
| 9714 | 1 | Behavioral Mode Status | UInt16 | - | 1 | R |
| 9715 | 2 | Count | UInt32 | - | 1 | R |
| 9717 | 2 | On Time | UInt32 | seconds | 1 | R |
| 9719 | 1 | Reserved | UInt16 | - | 1 | R |
| 9720 | 1 | Operating Mode Status | UInt16 | - | 1 | R |
| 9721 | 1 | Control Mode Status | UInt16 | - | 1 | R |
| 9722 | 1 | Behavioral Mode Status | UInt16 | - | 1 | R |
| 9723 | 2 | Count | UInt32 | - | 1 | R |
| 9725 | 2 | On Time | UInt32 | seconds | 1 | R |
| 9727 | 1 | Reserved | UInt16 | - | 1 | R |
| 9728 | 1 | Operating Mode Status | UInt16 | - | 1 | R |
| 9729 | 1 | Control Mode Status | UInt16 | - | 1 | R |
| 9730 | 1 | Behavioral Mode Status | UInt16 | - | 1 | R |
| 9731 | 2 | Count | UInt32 | - | 1 | R |
| 9733 | 2 | On Time | UInt32 | seconds | 1 | R |
| 9735 | 1 | Reserved | UInt16 | - | 1 | R |
| 10016 | 2 | Analog input 1 Scaled Value | Float32 | - | 1 | R |
| 10018 | 2 | Analog input 2 Scaled Value | Float32 | - | 1 | R |
| 10216 | 2 | Analog output 1 Normalized Value | Float32 | - | 1 | R |
| 10218 | 2 | Analog output 2 Normalized Value | Float32 | - | 1 | R |
| 20000 | 1 | Processor Loading | UInt16 | % | 1 | R |
Notes
Addresses are the 'Register' column of Schneider's public PM2xxx PMC register list (EM6400 NG, PM2120, PM2130, PM2220, PM2230 - file Public_PM2xxx PMC Register List, attached to Schneider FAQ FA311706) and are used unchanged in the Modbus frame; the ION-based PM2000/PM8000 platform numbers registers from 0 (Meter Name is register 30). Measurements are IEEE 754 single precision from register 3000, energies are Float32 in kWh/kVARh/kVAh, and the meter repeats most counters as 64-bit integers in Wh, which are not listed because this format cannot express 64-bit integers. The list covers the basic metering data, the system and meter setup and status registers, the I/O configuration and the communication registers. The advanced metering block (harmonics and waveform data from 21000), the alarm registers, the command interface (commands are written with function code 16 to the command registers 0-999) and the multi-tariff blocks of the register list are documented in the same file but are not repeated here. The RS-485 port is factory-set to slave address 1, 19200 bps and even parity (8 data bits, 1 stop bit; Schneider FAQ FA321406); it also supports 4800-38400 bps and odd or no parity, with 2 stop bits when parity is none. Units without an RS-485 port need an Ethernet-to-RS-485 gateway.