Everything you need to know to get started with Modbus Connect
The free Modbus TCP and RTU client these guides are written for — Windows, macOS and Linux, no trial timer.
Download the installer for your operating system from the download page. Run the installer and follow the setup wizard. Launch Modbus Connect from your applications menu.
Click the "Add Device" button in the sidebar. Enter your device's IP address, port (default: 502), and device ID (1-254).
For a device on RS-485 or RS-232, switch the connection type to Modbus RTU or Modbus ASCII instead of entering an IP address. Pick the serial port from the list (the app shows the USB adapter's name and has a rescan button), set the line settings to match the device's datasheet — baud rate 1200 to 115200, parity none/even/odd, 7 or 8 data bits, 1 or 2 stop bits and the response timeout — then enter the device ID. Modbus Connect does not guess line settings, so take them from the device. On Linux, your user account must be in the dialout group (uucp on Arch) before a real port will open.
Select your device, choose the register type (Holding Registers, Input Registers, Coils, or Discrete Inputs), set the start address and count, then click "Start Monitoring". Your data will appear in real-time. If a read fails, see Modbus Exception Codes Explained.
Automatically discover Modbus devices on your network:
For quiet and fast scan modes, CIDR ranges and what the scan results mean, read How to Scan a Modbus Network.
Monitor register values in real-time:
When a poll returns an error, the device answers with a Modbus exception code. Modbus Exception Codes Explained shows what each code means and what to check next.
Create real-time charts from your data:
Save and restore your complete setup:
A step-by-step walkthrough is in How to Scan a Modbus Network.
If several clients poll at once, the PLC itself may be the limit — see The PLC Resource Ceiling and Stress-Testing Modbus TCP.
When a register map changes between PLC revisions, see Versioning a Modbus Register Map.
In-depth articles on scanning, addressing, performance and connecting Modbus TCP to the rest of your stack.
Install the app, add a device and take the first reading.
Find every Modbus TCP device on a subnet with quiet and fast modes.
What each exception code means and what to check when one appears.
Keep register maps readable when the PLC program changes.
Where Modbus stops and an MQTT broker begins in an IIoT architecture.
Why a PLC stops answering when too many clients poll it.
The failure modes that only appear under load.
What each protocol is for, and when Modbus TCP is enough.
Why fewer, larger reads cut protocol overhead.
What a gateway translates, and what IEEE 2030.5 expects instead.