Conext MPPT 60 150 solar charge controller (XW-MPPT60-150, 865-1030 / 865-1030-1) Modbus register map

Default configuration

Protocol
Modbus TCP
Port
502
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first

Register map

AddressCountNameTypeUnitScaleAccess
08
Device Name
Ascii-1RW
1010
FGA Number
Ascii-1R
2010
Unique ID Number
Ascii-1R
3010
Firmware Version
Ascii-1R
401
Modbus Address
UInt16-1RW
411
Device Number
UInt16-1RW
421
System Instance
UInt16-1RW
4310
Hardware Serial Number
Ascii-1R
531
Configuration Status
0=Refreshing 1=Done
UInt16-1R
542
Configuration Refresh Counter
UInt32-1R
641
Device State
See section 2
UInt16-1R
651
Charger Enabled
0=Disabled 1=Enabled
UInt16-1R
661
Device Present
0=Inactive (all data invalid) 1=Active (data valid)
UInt16-1R
671
Charge Mode Status
0=Stand alone 1=Primary 2=Secondary
UInt16-1R
681
Active Faults Flag
0=No Active Faults 1=Has Active Faults
UInt16-1R
691
Active Warnings Flag
0=No Active Warnings 1=Has Active Warnings
UInt16-1R
701
Fault Bitmap 0
See section 3
UInt16-1R
711
Fault Bitmap 1
See section 4
UInt16-1R
721
Warning Bitmap 0
See section 5
UInt16-1R
731
Charger Status
See section 6
UInt16-1R
742
Configuration Errors
UInt32-1R
762
Input DC Voltage
UInt32V0.001R
782
Input DC Current
UInt32A0.001R
802
Input DC Power
UInt32W1R
861
Battery Temperature
UInt16°C0.01 (offset -273)R
882
Output DC Voltage
Int32V0.001R
902
Output DC Current
Int32A0.001R
922
Output DC Power
UInt32W1R
941
DC Power Output Percentage
UInt16%1R
951
Auxiliary Output Status
See section 7
UInt16-1R
962
Auxiliary Output Voltage
Int32V0.001R
1001
Auxiliary Output On Reason
See section 8
UInt16-1R
1011
Auxiliary Output Off Reason
See section 9
UInt16-1R
1022
Energy From PV This Hour
UInt32kWh0.001R
1042
PV Input Active This Hour
UInt32s1R
1062
Energy From PV Today
UInt32kWh0.001R
1082
PV Input Active Today
UInt32s1R
1102
Energy From PV This Week
UInt32kWh0.001R
1122
PV Input Active This Week
UInt32s1R
1142
Energy From PV This Month
UInt32kWh0.001R
1162
PV Input Active This Month
UInt32s1R
1182
Energy From PV This Year
UInt32kWh0.001R
1202
PV Input Active This Year
UInt32s1R
1222
Energy From PV Lifetime
UInt32kWh0.001R
1242
PV Input Active Lifetime
UInt32s1R
1262
Energy To Battery This Hour
UInt32kWh0.001R
1282
Battery Charge Active This Hour
UInt32s1R
1302
Energy To Battery Today
UInt32kWh0.001R
1322
Battery Charge Active Today
UInt32s1R
1342
Energy To Battery This Week
UInt32kWh0.001R
1362
Battery Charge Active This Week
UInt32s1R
1382
Energy To Battery This Month
UInt32kWh0.001R
1402
Battery Charge Active This Month
UInt32s1R
1422
Energy To Battery This Year
UInt32kWh0.001R
1442
Battery Charge Active This Year
UInt32s1R
1462
Energy To Battery Lifetime
UInt32kWh0.001R
1482
Battery Charge Active Lifetime
UInt32s1R
1601
MPPT Enable
0=Disable 1=Enable
UInt16-1RW
1622
MPPT Reference Voltage
UInt32V0.001RW
1651
Battery Type
See section 10
UInt16-1RW
1662
Nominal Battery Voltage
See section 11
UInt32V0.001RW
1681
Battery Bank Capacity
UInt16Ah1RW
1691
Battery Temperature Coefficient
The map prints this row's scale as -1.0 and its unit as mV/deg C.
UInt16mV/deg C-1RW
1701
Force Charger State
1=Bulk 2=Float 3=No Float
UInt16-1RW
1711
Reset
0=Reboot 2=Reset to Factory
UInt16-1RW
1721
Operating Mode
2=Standby 3=Operating
UInt16-1RW
1731
Clear
See section 12
UInt16-1RW
1742
Equalize Voltage Set Point
UInt32V0.001RW
1762
Bulk/Boost Voltage Set Point
UInt32V0.001RW
1782
Float Voltage Set Point
UInt32V0.001RW
1802
Recharge Voltage
UInt32V0.001RW
1822
Absorption Voltage Set Point
UInt32V0.001RW
1841
Absorption Time
The map prints this row's scale as 0.0166 (one sixtieth), so the reading is in minutes.
UInt16min0.0166RW
1851
Charge Cycle
1=3 Stage 2=2 Stage (No Float)
UInt16-1RW
1861
Maximum Charge Rate
UInt16%1RW
1871
Equalize Now
0=Disable 1=Enable
UInt16-1RW
1901
Charge Mode
See section 13
UInt16-1RW
1911
Default Battery Temperature
0=Cold 1=Warm 2=Hot
UInt16-1RW
1921
Identify Enable
0=Disable 1=Enable
UInt16-1RW
1931
Auxiliary Output Active Level
0=Active Low 1=Active High
UInt16-1RW
1942
Auxiliary Output Voltage
UInt32V0.001RW
1961
Manual Aux
0=Manual Off 1=Manual On 2=Automatic
UInt16-1RW
1981
Auxiliary Output Trigger Source
See section 14
UInt16-1RW
2002
Low Battery Voltage Trigger Set
UInt32V0.001RW
2021
Low Battery Voltage Trigger Set Delay
UInt16s0.01RW
2042
Low Battery Voltage Trigger Clear
UInt32V0.001RW
2061
Low Battery Voltage Trigger Clear Delay
UInt16s0.01RW
2082
High Battery Voltage Trigger Set
UInt32V0.001RW
2101
High Battery Voltage Trigger Set Delay
UInt16s0.01RW
2122
High Battery Voltage Trigger Clear
UInt32V0.001RW
2141
High Battery Voltage Trigger Clear Delay
UInt16s0.01RW
2162
High Array Voltage Trigger Set
UInt32V0.001RW
2181
High Array Voltage Trigger Set Delay
UInt16s0.01RW
2202
High Array Voltage Trigger Clear
UInt32V0.001RW
2221
High Array Voltage Trigger Clear Delay
UInt16s0.01RW
2242
Low Battery Temperature Trigger Set
UInt32°C0.001 (offset -273)RW
2261
Low Battery Temperature Trigger Set Delay
UInt16s0.01RW
2282
Low Battery Temperature Trigger Clear
UInt32°C0.001 (offset -273)RW
2301
Low Battery Temperature Trigger Clear Delay
UInt16s0.01RW
2322
High Battery Temperature Trigger Set
UInt32°C0.001 (offset -273)RW
2341
High Battery Temperature Trigger Set Delay
UInt16s0.01RW
2362
High Battery Temperature Trigger Clear
UInt32°C0.001 (offset -273)RW
2381
High Battery Temperature Trigger Clear Delay
UInt16s0.01RW
2402
High Heatsink Temperature Trigger Set
UInt32°C0.001 (offset -273)RW
2421
High Heatsink Temperature Trigger Set Delay
UInt16s0.01RW
2442
High Heatsink Temperature Trigger Clear
UInt32°C0.001 (offset -273)RW
2461
High Heatsink Temperature Trigger Clear Delay
UInt16s0.01RW
2481
Refresh Configuration Data
1=Refresh
UInt16-1RW
2491
DC Input Association (PV)
See section 15
UInt16-1RW
2501
DC Output Association (Battery)
See section 16
UInt16-1RW

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

The unit ID is a declared placeholder: the map prints the device's own 'Modbus Address' register but no factory value, and the Conext ComBox / Conext Gateway assigns the Modbus addresses itself (the ComBox Owner's Guide says it assigns them per device type at installation, valid 1-247, and lets you change or reset them), so read the address from the ComBox's Settings > Modbus Address List and use that. Port 502 is the ComBox's default Modbus TCP port as printed in its Owner's Guide. The map prints no function code; the ComBox writes its string registers with function code 0x10 (write multiple registers), so these rows are holding registers. Addresses are the map's own hexadecimal 'Modbus Address' column, stored as zero-based wire addresses. Rows whose type the map gives as str<nn> are seeded as Ascii rows of nn/2 registers. The MPPT 60 150 charge controller speaks Xanbus; these registers are the device map that the Conext ComBox or Conext Gateway presents over Modbus. Every register the map prints is in this file. The MPPT 80 600 (503-0252-01-01) has its own map and is not covered here. The printed hexadecimal numbers are the wire addresses (zero_based): in each of these maps the identity block is Device Name (str16) at 0x0000, FGA Number (str20) at 0x000A and Unique ID Number (str20) at 0x0014, so the ten registers of FGA Number run 0x000A-0x0013 into Unique ID Number at 0x0014, which only works if 0x0000 is register 0. The maps print no byte or word order for their uint32/sint32 rows, so HighFirst is the Modbus convention; if a two-register reading looks word-swapped, switch the device to LowFirst. Map: 'Modbus Map: Conext MPPT60 Device', 503-0248-01-01 Revision A.4, in Schneider's 'Conext Modbus Maps V4' pack.