SigenStor / Sigen Hybrid / Sigen PV Max Modbus register map

Download JSONSupplier documentationSuggest an edit

Default configuration

Protocol
Modbus TCP
Port
502
Unit ID
247
Addressing
0-based
Byte order
Big endian
Word order
High word first

Register map

AddressCountNameTypeUnitScaleAccess
300052
Grid sensor active power
Signed; positive means import from the grid.
Int32W1R
305992
ESS charge/discharge power
Signed; positive means charging (evcc inverts it so that charging is negative).
Int32W1R
306011
Battery state of charge
UInt16%0.1R
310172
Phase A current
Int32A0.01R
310192
Phase B current
Int32A0.01R
310212
Phase C current
Int32A0.01R
310352
PV power (per inverter)
Int32W1R
400461
Backup SoC
Discharge floor used when a Sigen Energy Gateway is installed. evcc's battery control writes this register only in that configuration, otherwise it writes 40048.
UInt16%0.1RW
400481
Discharge cut-off SoC
Discharge cut-off SoC. evcc's battery control writes this register on systems without a gateway (with a gateway it writes 40046 instead).
UInt16%0.1RW

Notes

Register map from the evcc template https://raw.githubusercontent.com/evcc-io/evcc/master/templates/definition/meter/sigenergy.yaml (Sigen Hybrid, Sigen PV Max, SigenStor EC). Modbus TCP on port 502 with unit ID 247, and it has to be enabled in the configuration app with installer rights - the customer app cannot switch it on. All entries are holding registers. The accumulated energy registers in this map (30562, 30568, 30574) are 64-bit values, which this specification cannot express, so they are left out rather than split. Discharge cut-off SoC is written in 0.1 % steps; systems with a Sigen Energy Gateway use the backup SoC register instead so the house stays powered during a grid outage. 40046 and 40048 are the only write registers in this map - evcc writes exactly one of the two, depending on the gateway option - so they are the only RW entries. Category changed from Solar inverter to Home battery (storage-centred).