MUST PV1800 (PV18-3024 VPM) solar inverter, with the PH1800 and EP1800 series the reference expects to work the same way Modbus register map

Serial device: in Modbus Connect, choose “Add to existing device” and pick the serial (RTU) device you created on your COM port.

Default configuration

Protocol
Modbus RTU over RS-485
Unit ID
4
Addressing
0-based
Byte order
Big endian
Word order
High word first
Baud rate
19200
Parity
None
Data bits
8
Stop bits
1

To read this device over Modbus RTU in Modbus Connect:

  1. In Modbus Connect, add a serial (RTU) device on your COM port with the serial settings and unit ID shown above.
  2. Click Add to Modbus Connect (or open the downloaded JSON), choose “Add to existing device” and pick that serial device. Its registers, byte order and word order are added; the serial device keeps its own line settings.

The “Add device” tab creates a Modbus TCP device (IP address and port), so use it only when you reach this device through a Modbus RTU-to-TCP gateway set to the serial settings above.

Register map

AddressCountNameTypeUnitScaleAccess
101021
Absorb Voltage
Int16V0.1R
101071
Battery High Voltage
Int16V0.1R
101091
Absorb Charger Current
Int16A0.1R
152011
Charger Workstate
The reference prints no unit for this row (raw register value).
Int16-1R
152021
Mppt State
The reference prints no unit for this row (raw register value).
Int16-1R
152031
Charging State
The reference prints no unit for this row (raw register value).
Int16-1R
152051
Pv Voltage
Int16V0.1R
152061
Battery Voltage
Int16V0.1R
152071
Charger Current
Int16A0.1R
152081
Charger Power
Int16W1R
152091
Radiator Temperature
Int16°C1R
152101
External Temperature
Int16°C1R
152111
Battery Relay
0/1 flag, as the reference reads it.
Int16-1R
152121
Pv Relay
0/1 flag, as the reference reads it.
Int16-1R
152151
Batt Vol Grade
Int16V1R
152161
Rated Current
Int16A0.1R
201281
Inverter Battery High Voltage
Int16V0.1R
201421
System Setting
The reference prints no unit for this row (raw register value).
UInt16-1R
252011
Work State
The reference prints no unit for this row (raw register value).
Int16-1R
252021
Ac Voltage Grade
Int16V1R
252031
Rated Power
Int16VA1R
252051
Inverter Battery Voltage
Int16V0.1R
252061
Inverter Voltage
Int16V0.1R
252071
Grid Voltage
Int16V0.1R
252081
Bus Voltage
Int16V0.1R
252091
Control Current
Int16A0.1R
252101
Inverter Current
Int16A0.1R
252111
Grid Current
Int16A0.1R
252121
Load Current
Int16A0.1R
252131
P Inverter
Int16W1R
252141
P Grid
Int16W1R
252151
P Load
Int16W1R
252161
Load Percent
Int16%1R
252171
S Inverter
Int16VA1R
252181
S Grid
Int16VA1R
252191
Sload
Int16VA1R
252211
Qinverter
Int16var1R
252221
Qgrid
Int16var1R
252231
Qload
Int16var1R
252251
Inverter Frequency
Int16Hz0.01R
252261
Grid Frequency
Int16Hz0.01R
252291
Inverter Max Number
The reference prints no unit for this row (raw register value).
UInt16-1R
252301
Combine Type
The reference prints no unit for this row (raw register value).
UInt16-1R
252311
Inverter Number
The reference prints no unit for this row (raw register value).
UInt16-1R
252331
Ac Radiator Temperature
Int16°C1R
252341
Transformer Temperature
Int16°C1R
252351
Dc Radiator Temperature
Int16°C1R
252371
Inverter Relay State
0/1 flag, as the reference reads it.
Int16-1R
252381
Grid Relay State
0/1 flag, as the reference reads it.
Int16-1R
252391
Load Relay State
0/1 flag, as the reference reads it.
Int16-1R
252401
N_Line Relay State
0/1 flag, as the reference reads it.
Int16-1R
252411
DC Relay State
0/1 flag, as the reference reads it.
Int16-1R
252421
Earth Relay State
0/1 flag, as the reference reads it.
Int16-1R
252731
Batt Power
Int16W1R
252741
Batt Current
Int16A1R
252771
Rated Power W
Int16W1R

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

SECONDARY SOURCE (community reverse-engineered map): github.com/mukaschultze/ha-must-inverter, commit ae92a28350bb625e3733f98878657468be1d2c8c, const.py (SHA-256 0a3656253c58de76afe92acebe3349ea844cb6266fd3870b8d7af4faed7517a0) and mapper.py (SHA-256 bd6d69aa0eab00df8b5b49c8e1eed58c7de43d16b4aa4b1c4686c0234873a905); read 2026-11-23. Its README says it is tested on a MUST PV18-3024 VPM (PV1800), the PV19/PV1900 EXP and PH11/PH1100 EU series and "should work with other models that use the same protocol, such as the PH1800 and EP1800 series" - hence the model string; no PV3500/EP3500 claim. That testing is the integration's claim, not the vendor's; it is unaffiliated with MUST and reverse-engineered. FRAME (config_flow defaults): /dev/ttyUSB0, 19200 8N1, parity N; unit ID default 0x04 (const.py DEFAULT_DEVICE_ID). FUNCTION: read_holding_registers(address, count), so these are holding registers at the decimal addresses printed, stored unchanged (zero_based). Seeded: the single-register read-only rows - every const.py SENSOR or BINARY_SENSOR that mapper.py decodes with int16 or uint16 - with its coefficients, units and signedness (mapper's int16 is signed; the uint16 rows are the count/code registers). Not seeded: the NUMBER, SWITCH, SELECT, TIME and BUTTON entries, which are settings and commands, and the rows it computes from more than one register or decodes by table (accumulated kWh, error and warning bit strings, version strings, serial number, machine model, equalisation times, a duration row). Also not seeded: the model-specific arrays it only reads for other inverters (PH1100 15104-15119, PV1900 113/114 and 16205-16208) and the const.py SENSOR entries mapper.py never decodes (25227-25265). Its caution is repeated: some registers cannot be restored once written and its calibration coefficients are disabled by default.