ND40 power network analyser (ND40-09C with Ethernet) Modbus register map

Default configuration

Protocol
Modbus TCP
Port
502
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first

Register map

AddressCountNameTypeUnitScaleAccess
2002
Voltage RMS (L1)
Float32V1R
2022
Current RMS (L1)
Float32A1R
2042
Primary voltage (L1)
Float32V1R
2062
Active power (L1)
Float32W1R
2082
Reactive power (L1)
Float32var1R
2102
Apparent power (L1)
Float32VA1R
2122
Power distortion factor (L1)
Float32-1R
2142
Active power factor (L1)
Float32-1R
2162
tgφ factor (L1)
Float32-1R
2202
Angle between the voltage and current (L1)
Float32rad1R
2242
Voltage RMS (L2)
Float32V1R
2262
Current RMS (L2)
Float32A1R
2282
Primary voltage (L2)
Float32V1R
2302
Active power (L2)
Float32W1R
2322
Reactive power (L2)
Float32var1R
2342
Apparent power (L2)
Float32VA1R
2362
Power distortion factor (L2)
Float32-1R
2382
Active power factor (L2)
Float32-1R
2402
tgφ factor (L2)
Float32-1R
2442
Angle between the voltage and current (L2)
Float32rad1R
2482
Voltage RMS (L3)
Float32V1R
2502
Current RMS (L3)
Float32A1R
2522
Primary voltage (L3)
Float32V1R
2542
Active power (L3)
Float32W1R
2562
Reactive power (L3)
Float32var1R
2582
Apparent power (L3)
Float32VA1R
2602
Power distortion factor (L3)
Float32-1R
2622
Active power factor (L3)
Float32-1R
2642
tgφ factor (L3)
Float32-1R
2682
Angle between the voltage and current (L3)
Float32rad1R
2722
Average voltage (L123)
Float32V1R
2742
Average current (L123)
Float32A1R
2762
Average primary voltage (L123)
Float32V1R
2782
Sum of active power (L123)
Float32W1R
2802
Sum of reactive power (L123)
Float32var1R
2822
Sum of apparent power (L123)
Float32VA1R
2842
Average value of power distortion factor (L123)
Float32-1R
2862
Average value of active power factor (L123)
Float32-1R
2882
Average value of tgφ factor (L123)
Float32-1R
2902
Phase-to-phase voltage L1-2 (L123)
Float32V1R
2922
Phase-to-phase voltage L2-3 (L123)
Float32V1R
2942
Phase-to-phase voltage L3-1 (L123)
Float32V1R
2962
Average phase-to-phase voltage (L123)
Float32-1R
2982
Average active power (L123)
Float32W1R
3002
Average reactive power (L123)
Float32var1R
3022
Average apparent power (L123)
Float32VA1R
3042
Current in neutral wire (L123)
Float32A1R
3062
Recalculated current in neutral wire (L123)
Float32A1R
3082
Average angle between voltage and current (L123)
Float32rad1R
3122
Voltage phase-to-phase angle L1-2 (L123)
Float32°1R
3142
Voltage phase-to-phase angle L2-3 (L123)
Float32°1R
3162
Voltage phase-to-phase angle L3-1 (L123)
Float32°1R
3182
Average value of phase-to-phase angle (L123)
Float32°1R
8182
Frequency (1 s aggregation)
Float32Hz1R
8202
Frequency (10 s aggregation)
Float32Hz1R
9022
Active imported energy L1
Float32kWh1R
9062
Active imported energy L2
Float32kWh1R
9102
Active imported energy L3
Float32kWh1R
9142
Sum of active imported energy (L123)
Float32kWh1R
9182
Active exported energy L1
Float32kWh1R
9222
Active exported energy L2
Float32kWh1R
9262
Active exported energy L3
Float32kWh1R
9302
Sum of active exported energy (L123)
Float32kWh1R

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

TCP device: the ND40-09C has an Ethernet interface with a Modbus TCP/IP server, configured in section 5.7.2 "Configuration of Modbus TCP". Source: Lumel "ND40-09C User's Manual" (read here as the English edition served by www.lumel.de, 9,210,789 bytes), section 12.8 "Tables of registers" (12.8.5 parameters measured with 1 s aggregation, 0200-0318; 12.8.10 frequency 0818/0820; 12.8.12 energy meters). The manual states that 32-bit registers (4 bytes, 2 x 16 bits) hold "float registers with bytes placed as follows: B4 B3 B2 B1" and that "all given addresses are physical addresses" (programs using logical addressing add 1), so every row is a Float32 with the high byte first and the printed number is stored as the zero-based wire address. Those printed addresses are decimal, not hexadecimal: the column runs 0298 -> 0300, 0318 -> 0320 and 0998 -> 1000, carries only a decimal count produces. Each row carries the manual's own unit (V, A, W, var, VA, rad, degrees, Hz, kWh); the distortion and power-factor rows print "-" and have none. Only the 1 s aggregation block is seeded: the 200 ms, 3 s, 10 min and 2 h blocks repeat the same quantities at 0050-0170, 0350-0470, 0500-0618 and 0650-0768. Also left out: the reserved rows 0218/0242/0266, the degree twins of the four angle registers (0222, 0246, 0270, 0310), voltage asymmetry 0320, and every energy row except the eight kWh counters (the MWh twins and the 0932-1012 reactive and apparent energy). Neither the Modbus chapter nor the register tables state a factory Modbus TCP port or address, so the seed keeps port 502 and unit ID 1 as a placeholder. This is not a duplicate of any library seed: Lumel is not in the library.