EnergyPro 2000 (EP2000, EBOX) Modbus register map
Default configuration
- Protocol
- Modbus TCP
- Port
- 502
- Unit ID
- 1
- Addressing
- 0-based
- Byte order
- Big endian
- Word order
- Low word first
Register map
| Address | Count | Name | Type | Unit | Scale | Access |
|---|---|---|---|---|---|---|
| 50001 | 1 | Number of Inverters | UInt16 | - | 1 | R |
| 50002 | 2 | AC Load Power (Total) | UInt32 | W | 1 | R |
| 50004 | 2 | PV Power (Total) | UInt32 | W | 1 | R |
| 50006 | 2 | Grid Power (Total) Signed 32-bit value, as the sheet's type column is int. The sheet prints no sign convention for the totals row; the vendor repository's issue #12 measures this total as the sum of the three phase magnitudes (17725 W for phases of -6525, -6671 and -4521 W), so import and export cannot be told apart in it. It is the power at the unit's own grid port, not at the meter's grid connection. | Int32 | W | 1 | R |
| 50008 | 2 | Inverter Power (Total) Signed 32-bit value, as the sheet's type column is int. | Int32 | W | 1 | R |
| 50010 | 2 | PV to AC Load Power | UInt32 | W | 1 | R |
| 50012 | 2 | AC Load Energy (Total) Total energy delivered to the AC loads, 0.1 kWh per count. The vendor repository's issue #12 reports this and the other 50012-50020 totals as always 0 on the EP2000 units measured; the counters are filled over Bluetooth only after a request. | UInt32 | kWh | 0.1 | R |
| 50014 | 2 | PV Charging Energy (Total) Reads 0 on the EP2000 units measured (vendor repository issue #12); see 50012. | UInt32 | kWh | 0.1 | R |
| 50016 | 2 | Grid Charging Energy (Total) Reads 0 on the EP2000 units measured (vendor repository issue #12); see 50012. | UInt32 | kWh | 0.1 | R |
| 50018 | 2 | Feed-in Grid Energy Reads 0 on the EP2000 units measured (vendor repository issue #12); see 50012. | UInt32 | kWh | 0.1 | R |
| 50020 | 2 | PV to AC Load Energy Reads 0 on the EP2000 units measured (vendor repository issue #12); see 50012. | UInt32 | kWh | 0.1 | R |
| 50022 | 1 | Inverter Operating Status 0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging, 6 = inverter fault, 7 = abnormal off-grid. Values as printed in the vendor sheet. | UInt16 | - | 1 | R |
| 50032 | 16 | Manufacturer information | Ascii | - | 1 | R |
| 50048 | 2 | Grid-port reactive power (sum) | Int32 | var | 1 | R |
| 50050 | 2 | Grid-port apparent power (sum) | Int32 | VA | 1 | R |
| 50052 | 2 | Battery power Signed 32-bit value. The sheet prints no sign convention for this row. | Int32 | W | 1 | R |
| 50200 | 6 | Inverter Type | Ascii | - | 1 | R |
| 50214 | 1 | Grid Access Frequency | UInt16 | Hz | 0.1 | R |
| 50215 | 2 | Grid Charging Power (Single) | Int32 | W | 1 | R |
| 50217 | 2 | AC Load Power (Single) | UInt32 | W | 1 | R |
| 50219 | 2 | PV Charging Power (Single) | UInt32 | W | 1 | R |
| 50221 | 2 | PV to AC Load Power (Single) | UInt32 | W | 1 | R |
| 50223 | 2 | Grid Charging Energy (Single) Per-inverter counter; reads 0 on the EP2000 units measured (vendor repository issue #12). | UInt32 | kWh | 0.1 | R |
| 50225 | 2 | Feed-in Grid Energy (Single) Per-inverter counter; reads 0 on the EP2000 units measured (vendor repository issue #12). | UInt32 | kWh | 0.1 | R |
| 50227 | 2 | AC Load Energy (Single) Per-inverter counter; reads 0 on the EP2000 units measured (vendor repository issue #12). | UInt32 | kWh | 0.1 | R |
| 50229 | 2 | PV Charging Energy (Single) Per-inverter counter; reads 0 on the EP2000 units measured (vendor repository issue #12). | UInt32 | kWh | 0.1 | R |
| 50231 | 2 | PV to AC Load Energy (Single) Per-inverter counter; reads 0 on the EP2000 units measured (vendor repository issue #12). | UInt32 | kWh | 0.1 | R |
| 50234 | 1 | System Phase Number | UInt16 | - | 1 | R |
| 50236 | 1 | Grid1 Voltage | UInt16 | V | 0.1 | R |
| 50237 | 1 | Grid1 Current | Int16 | A | 0.1 | R |
| 50239 | 1 | Grid2 Voltage | UInt16 | V | 0.1 | R |
| 50240 | 1 | Grid2 Current | Int16 | A | 0.1 | R |
| 50242 | 1 | Grid3 Voltage | UInt16 | V | 0.1 | R |
| 50243 | 1 | Grid3 Current | Int16 | A | 0.1 | R |
| 50244 | 1 | AC System Phase Number | UInt16 | - | 1 | R |
| 50245 | 1 | AC Load1 Power | UInt16 | W | 1 | R |
| 50246 | 1 | AC Load1 Voltage | UInt16 | V | 0.1 | R |
| 50247 | 1 | AC Load1 Current | UInt16 | A | 0.1 | R |
| 50248 | 1 | AC Load2 Power | UInt16 | W | 1 | R |
| 50249 | 1 | AC Load2 Voltage | UInt16 | V | 0.1 | R |
| 50250 | 1 | AC Load2 Current | UInt16 | A | 0.1 | R |
| 50251 | 1 | AC Load3 Power | UInt16 | W | 1 | R |
| 50252 | 1 | AC Load3 Voltage | UInt16 | V | 0.1 | R |
| 50253 | 1 | AC Load3 Current | UInt16 | A | 0.1 | R |
| 50254 | 1 | Inverter System Phase Number | UInt16 | - | 1 | R |
| 50255 | 1 | Inverter1 Operation Status 0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging. | UInt16 | - | 1 | R |
| 50256 | 1 | Inverter1 Power | UInt16 | W | 1 | R |
| 50257 | 1 | Inverter1 Voltage | UInt16 | V | 0.1 | R |
| 50258 | 1 | Inverter1 Current | UInt16 | A | 0.1 | R |
| 50259 | 1 | Inverter2 Operation Status 0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging. | UInt16 | - | 1 | R |
| 50260 | 1 | Inverter2 Power | UInt16 | W | 1 | R |
| 50261 | 1 | Inverter2 Voltage | UInt16 | V | 0.1 | R |
| 50262 | 1 | Inverter2 Current | UInt16 | A | 0.1 | R |
| 50263 | 1 | Inverter3 Operation Status 0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging. | UInt16 | - | 1 | R |
| 50264 | 1 | Inverter3 Power | UInt16 | W | 1 | R |
| 50265 | 1 | Inverter3 Voltage | UInt16 | V | 0.1 | R |
| 50266 | 1 | Inverter3 Current | UInt16 | A | 0.1 | R |
| 50267 | 1 | PV Total Number Bit 0-3 = number of DC PV inputs, bit 4-7 = number of AC PV inputs. | UInt16 | - | 1 | R |
| 50268 | 1 | PV1 Type 0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them | UInt16 | - | 1 | R |
| 50269 | 1 | PV1 Input Power | UInt16 | W | 1 | R |
| 50270 | 1 | PV1 Input Voltage | UInt16 | V | 0.1 | R |
| 50271 | 1 | PV1 Input Current | UInt16 | A | 0.1 | R |
| 50272 | 1 | PV2 Type 0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. The EP2000 has two DC MPPT inputs, reported as PV1 and PV2: the slots from PV3 up read junk on measured units, and AC-coupled solar is not reported here at all (vendor repository issues #12 and #145). | UInt16 | - | 1 | R |
| 50276 | 1 | PV3 Type 0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. The EP2000 has two DC MPPT inputs, reported as PV1 and PV2: the slots from PV3 up read junk on measured units, and AC-coupled solar is not reported here at all (vendor repository issues #12 and #145). | UInt16 | - | 1 | R |
| 50280 | 1 | PV4 Type 0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. The EP2000 has two DC MPPT inputs, reported as PV1 and PV2: the slots from PV3 up read junk on measured units, and AC-coupled solar is not reported here at all (vendor repository issues #12 and #145). | UInt16 | - | 1 | R |
| 50284 | 1 | PV5 Type 0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. The EP2000 has two DC MPPT inputs, reported as PV1 and PV2: the slots from PV3 up read junk on measured units, and AC-coupled solar is not reported here at all (vendor repository issues #12 and #145). | UInt16 | - | 1 | R |
| 50400 | 2 | Hardware version ASCII. Reads empty on every EP2000 measured, like the rest of the 50400-50410 block (vendor repository issue #12). | Ascii | - | 1 | R |
| 50402 | 1 | Active power Reads 0 on every EP2000 measured, like the rest of its block (vendor repository issue #12). | Int16 | W | 1 | R |
| 50403 | 1 | Reactive power Reads 0 on every EP2000 measured, like the rest of its block (vendor repository issue #12). | Int16 | var | 1 | R |
| 51002 | 1 | Total Pack Voltage | UInt16 | V | 0.1 | R |
| 51003 | 1 | Total Pack Current | UInt16 | A | 0.1 | R |
| 51009 | 2 | Maximum energy storage capacity (Wh) | UInt32 | Wh | 1 | R |
| 51011 | 2 | Maximum energy storage capacity (Ah) | UInt32 | Ah | 1 | R |
| 51013 | 1 | Rated battery voltage | UInt16 | V | 0.1 | R |
| 51014 | 2 | Maximum charge rate into the storage system | UInt32 | W | 1 | R |
| 51016 | 2 | Maximum discharge rate out of the storage system | UInt32 | W | 1 | R |
| 51200 | 6 | Pack Type | Ascii | - | 1 | R |
| 51210 | 1 | Total Pack Software Number | UInt16 | - | 1 | R |
| 51219 | 1 | Pack Voltage | UInt16 | V | 0.1 | R |
| 51220 | 1 | Pack Current The sheet types the pack current as unsigned, but two EP2000 systems and a third unit read it signed: 62 while charging (6.2 A) and 65518 while discharging (-1.8 A) at 0.1 A a count (vendor repository issue #12). The community register file still declares it unsigned; the measurement is followed here. | Int16 | A | 0.1 | R |
| 51221 | 1 | Pack SOC | UInt16 | % | 1 | R |
| 51222 | 1 | Pack SOH | UInt16 | % | 1 | R |
| 51223 | 1 | Pack Cycle Count | UInt16 | - | 1 | R |
| 51224 | 1 | Pack Average Temperature Degrees Celsius plus 40: a measured unit read 58 at the same moment as 18 °C in the app and on a thermal camera, and the sheet's own -40 to 160 range fits that encoding (vendor repository issues #12 and #145). The offset applies the -40. | Int16 | °C | 1 (offset -40) | R |
| 51234 | 1 | Pack Total Cell Count | UInt16 | - | 1 | R |
| 51235 | 1 | Pack Total NTC Count | UInt16 | - | 1 | R |
| 51236 | 2 | Pack Total Charging Energy | UInt32 | Wh | 1 | R |
| 51238 | 2 | Pack Total Discharging Energy | UInt32 | Wh | 1 | R |
| 51248 | 1 | Pack Estimated Full Charge Time Minutes. On measured units this estimate and its discharge counterpart 51249 always read the same value, charging or discharging (vendor repository issue #12). | UInt16 | min | 1 | R |
| 51249 | 1 | Pack Estimated Full Discharge Time Minutes. Reads the same value as 51248 on measured units. | UInt16 | min | 1 | R |
| 53001 | 6 | IoT Model | Ascii | - | 1 | R |
| 57001 | 1 | AC load output switch 0 = off, 1 = on. | UInt16 | - | 1 | RW |
| 57009 | 1 | AC grid charging switch 0 = off, 1 = on. | UInt16 | - | 1 | RW |
| 57010 | 1 | AC grid feed-in switch 0 = off, 1 = on. | UInt16 | - | 1 | RW |
| 57016 | 1 | Battery empty SOC threshold Discharging stops at this state of charge. The sheet prints 0 to 100, in percent, as the valid range. | UInt16 | % | 1 | RW |
| 57017 | 1 | Battery full SOC threshold Charging stops at this state of charge. The sheet prints 0 to 100, in percent, as the valid range. | UInt16 | % | 1 | RW |
| 57030 | 1 | Remote control (EMS control) Bits 0-3 are the remote-control enable: 6 = remote control enabled, 4 = remote control disabled so the unit follows its own control; the sheet prints 4 and 6 as the valid values and bits 4-15 as reserved. This is the master switch for the targets below. Writing any of them is untested on hardware: the community profile keeps this whole control block read-only until each register has been written on a unit of its own, and behind the VPP option (which is also what opens port 502 on this model, see notes) an aggregator may overwrite what is set here. | UInt16 | - | 1 | RW |
| 57032 | 2 | Active power target, phase A Signed active power target for phase A, in W: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | W | 1 | R |
| 57034 | 2 | Active power target, phase B Signed active power target for phase B, in W: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. This row alone also carries the sheet's further remark "dark: reserved", and the whole 57034-57053 block is shaded dark. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | W | 1 | R |
| 57036 | 2 | Active power target, phase C Signed active power target for phase C, in W: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | W | 1 | R |
| 57038 | 2 | Reactive power target, phase A Signed reactive power target for phase A, in var: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | var | 1 | R |
| 57040 | 2 | Reactive power target, phase B Signed reactive power target for phase B, in var: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | var | 1 | R |
| 57042 | 2 | Reactive power target, phase C Signed reactive power target for phase C, in var: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | var | 1 | R |
| 57044 | 2 | Apparent power target, phase A Signed apparent power target for phase A, in VA: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | VA | 1 | R |
| 57046 | 2 | Apparent power target, phase B Signed apparent power target for phase B, in VA: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | VA | 1 | R |
| 57048 | 2 | Apparent power target, phase C Signed apparent power target for phase C, in VA: the sheet's remark for this block reads feed-in to the grid is positive, charging is negative, 0xFFFFFFFF = invalid. The sheet lists this register read/write but prints no value range for it, so the write is left out here and the row is read-only. | Int32 | VA | 1 | R |
| 57050 | 1 | Active power output level (% of rated) Setpoint as a percentage of maximum rated active power, with feed-in positive and charging negative; the sheet prints -100 to 100 as the valid range. Untested on hardware, see 57030. | Int16 | % of Wmax | 1 | RW |
Read this device live with Modbus Connect, free for Windows, macOS and Linux
Related guides
Notes
Register map from BLUETTI's open Modbus TCP list, bluetti-official/bluetti-modbus-tcp-slave at commit cee4c98e: doc/Bluetti-Open-Modbus-TCP-register-list.xlsx (SHA-256 aa7687c5be29c605d03aef1957b5f79ee52000debe564a4d1038d9efce0a1371), sheet "EBOX", retrieved 2026-11-23. Its README gives the transport: Modbus TCP slave, address 1 by default, port from the web page (502 in the example). On the EP2000 that page has no such switch: the VPP option in the BLUETTI app opens port 502 (bluetti-community/hassio-bluetti-modbus issue #145, 2026-10-02), and VPP also lets an aggregator charge and discharge the battery. Function 3 at the sheet's addresses; its unit column is the scale. 32-bit values are LITTLE word first: the workbook states "Register Data principle: Little-end storage; Modbus Protocol transmission principle: Big-end transmission", and bluetti-community/bluetti-modbus, the HA library, decodes multi-word values with word_order="little" (bluetti-registers#20). Left out, and why: 51001 and 51004-51008, which answer only at unit ID 250 and read 0 at a device's own unit ID (Home Assistant core's bluetti_modbus); the SunSpec rows 50054-50310 without units and the DER status rows 50404-50410, in a block that reads empty on measured units; the 64-bit serials, the version registers, the BMS protect/error/alarm words, the int-or-uint grid power rows, the PV2-PV5 measurement rows (unit column slip; issue #12 measures 1 W / 0.1 V / 0.1 A), and the control rows with no printed valid values (57051-57513). The nine per-phase targets 57032-57048 are listed read/write but print no range, so they are read-only here. Cross-checked against bluetti-community/bluetti-registers at 3f0707a6 (ep2000.json): addresses agree. Seven write registers are seeded with their valid values; none is hardware-tested, the community profile keeping this block read-only. It has been read on three real units (issue #145), whose corrections are in the rows below, but written to by no source found.