ASW H-TH hybrid (AISWEI protocol MB001_ASW GEN-Modbus V2.1.7) Modbus register map

Download JSONSupplier documentationSuggest an edit

Default configuration

Protocol
Modbus TCP
Port
502
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first

Register map

AddressCountNameTypeUnitScaleAccess
16002
PV total power
UInt32W1R
16042
PV energy total
UInt32kWh0.1R
16182
BMS1 battery power
Signed; positive means discharging.
Int32W1R
16211
BMS1 state of charge
UInt16%1R
17512
BMS2 battery power
Signed; positive means discharging.
Int32W1R
17541
BMS2 state of charge
UInt16%1R

Notes

Register map from the evcc template https://raw.githubusercontent.com/evcc-io/evcc/master/templates/definition/meter/solplanet-modbus.yaml, which targets AISWEI/APsystems protocol 'MB001_ASW GEN-Modbus' V2.1.7 - Solplanet ASW-TH series and the KACO blueplanet hybrid NH3 (Ethernet ports ETH5/ETH6). Modbus TCP on port 502, unit ID 1. Only units with this dedicated Ethernet port serve the map; older units behind the AI dongle do not. Measurements are input registers, settings holding registers. The grid meter import/export counters are not exposed over Modbus TCP by this firmware. Two battery packs are addressed separately (BMS1 at 1618/1621, BMS2 at 1751/1754). Battery compatibility: AISWEI/Solplanet's hybrid compatibility list (V1.9, July 2026) puts Solplanet's Ai-HB G2 / Ai-HB G2 PRO / Ai-HB G2-E packs alongside Pylontech, Dyness AP-H, Lithium Valley, FEB Powercube and BYD Battery-Box HVS/HVM on the ASW H-series hybrids - https://solplanet.net/wp-content/uploads/2024/12/Hybrid-battery-compatibility-list-V1.9-Jul-2026.pdf.