All devices

PACE · Home battery

PACE BMS rack battery management system, Modbus protocol for RS485 (the document references the BMS-4820 pack) Modbus register map

Serial device: in Modbus Connect, choose “Add to existing device” and pick the serial (RTU) device you created on your COM port.

Default configuration

Protocol
Modbus RTU over RS-485
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first
Baud rate
9600
Parity
None
Data bits
8
Stop bits
1

To read this device over Modbus RTU in Modbus Connect:

  1. In Modbus Connect, add a serial (RTU) device on your COM port with the serial settings and unit ID shown above.
  2. Click Add to Modbus Connect (or open the downloaded JSON), choose “Add to existing device” and pick that serial device. Its registers, byte order and word order are added; the serial device keeps its own line settings.

The “Add device” tab creates a Modbus TCP device (IP address and port), so use it only when you reach this device through a Modbus RTU-to-TCP gateway set to the serial settings above.

Register map

AddressCountNameTypeUnitScaleAccess
01
Pack current
Positive while charging, negative while discharging, as the document prints.
Int16A0.01R
11
Pack voltage
UInt16V0.01R
21
State of charge (SOC)
UInt16%1R
31
State of health (SOH)
UInt16%1R
41
Remaining capacity
UInt16Ah0.01R
51
Full charge capacity
UInt16Ah0.01R
61
Design capacity
UInt16Ah0.01R
71
Battery cycle count
UInt16-1R
91
Warning flag
Bit field, 1 = occurring, 0 = not occurring: 0 cell over-voltage alarm, 1 cell low-voltage alarm, 2 pack over-voltage alarm, 3 pack low-voltage alarm, 4 charging over-current alarm, 5 discharging over-current alarm, 6-7 reserved, 8 charging high-temperature alarm (cell temperature), 9 discharging high-temperature alarm (cell temperature), 10 charging low-temperature alarm (cell temperature), 11 discharging low-temperature alarm (cell temperature), 12 environment high-temperature alarm, 13 environment low-temperature alarm, 14 MOSFET high-temperature alarm, 15 SOC low alarm.
UInt16-1R
101
Protection flag
Bit field, 1 = occurring, 0 = not occurring: 0 cell over-voltage protection, 1 cell low-voltage protection, 2 pack over-voltage protection, 3 pack low-voltage protection, 4 charging over-current protection, 5 discharging over-current protection, 6 short-circuit protection, 7 charger over-voltage protection, 8 charging high-temperature protection (cell temperature), 9 discharging high-temperature protection (cell temperature), 10 charging low-temperature protection (cell temperature), 11 discharging low-temperature protection (cell temperature), 12 MOSFET high-temperature protection, 13 environment high-temperature protection, 14 environment low-temperature protection, 15 reserved.
UInt16-1R
111
Status and fault flag
Bit field. Faults: 0 charging MOSFET fault, 1 discharging MOSFET fault, 2 temperature sensor fault, 3 reserved, 4 cell fault, 5 front-end sampling communication fault, 6-7 reserved. Status: 8 state of charge, 9 state of discharge, 10 charging MOSFET on, 11 discharging MOSFET on, 12 charging limiter on, 13 reserved, 14 charger reversed, 15 heater on.
UInt16-1R
121
Balance status
Hex value as printed; the document gives it no unit and no bit table, and no per-cell decode is seeded.
UInt16-1R
151
Cell 1 voltage
UInt16mV1R
161
Cell 2 voltage
UInt16mV1R
171
Cell 3 voltage
UInt16mV1R
181
Cell 4 voltage
UInt16mV1R
191
Cell 5 voltage
UInt16mV1R
201
Cell 6 voltage
UInt16mV1R
211
Cell 7 voltage
UInt16mV1R
221
Cell 8 voltage
UInt16mV1R
231
Cell 9 voltage
UInt16mV1R
241
Cell 10 voltage
UInt16mV1R
251
Cell 11 voltage
UInt16mV1R
261
Cell 12 voltage
UInt16mV1R
271
Cell 13 voltage
UInt16mV1R
281
Cell 14 voltage
UInt16mV1R
291
Cell 15 voltage
UInt16mV1R
301
Cell 16 voltage
UInt16mV1R
311
Cell temperature 1
Int16°C0.1R
321
Cell temperature 2
Int16°C0.1R
331
Cell temperature 3
Int16°C0.1R
341
Cell temperature 4
Int16°C0.1R
351
MOSFET temperature
The document notes the value may be invalid on some models (BMS-4820).
Int16°C0.1R
361
Environment temperature
The document notes the value may be invalid on some models (BMS-4820).
Int16°C0.1R

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

Source: PACE "PACE BMS Modbus Protocol for RS485", V1.3, 2017-06-27, prepared by YX.WANG, read from the vendor-document mirror github.com/syssi/esphome-pace-bms docs/PACE-BMS-Modbus-Protocol-for-RS485-V1.3-20170627.pdf (2026-11-23, SHA-256 2aee34db485aad190f039bc314ff82896692c739513263d9f2a1a5c9bf34dc16). MIRROR-SOURCED: PACE serves no download, so this copy is cited. The document names no product code beyond the protocol title; its revision history mentions the BMS-4820 pack. Framing (section 2): 9600 bps ("Default, subject to the BMS specification"), no parity, 8 data bits, 1 stop bit, 200 ms timeout, frames >100 ms apart. Functions 0x03 read and 0x10 write, so every row is a holding register. Addresses: the "Register Address" column carries in decimal (0079, 0080, 0081 and 0099, 0100) and prints no A-F digits, so it is decimal and the seed stores it as printed (zero_based). The cell block proves it: 0015-0030 holds 16 cells of 32 bytes, which is 16 values only in decimal, and the mirror's own table numbers them 15 to 30. The DIP-switch table gives module addresses 0x01-0x10 with no factory default and the example frames use 0x01, so unit 1 is a placeholder. Seeded: current, pack voltage, SOC, SOH, remaining/full/design capacity, cycle count, the warning, protection and status/fault words decoded from the document's bit tables, the balance word, 16 cell voltages, four cell temperatures, MOSFET and environment temperature. SOC and SOH are UINT8 in a two-byte field, seeded as UInt16 because the format has no 8-bit type. READ-ONLY: the ten protection-delay and SOC-alarm settings (0x3F, 0x43, 0x47, 0x4B, 0x4E, 0x51, 0x53, 0x6F, 0x72, 0x70) are left out: a range is printed, but a longer delay weakens protection. Not seeded: the rest of 0060-0114 (units and types printed, no min/max), the reserved ranges, and the ASCII blocks 0150-0159 and 0160-0179 (ranges and byte counts only, no content). No hardware validation is claimed by the source.

Related devices