Venus E Gen 1 / Venus E Gen 2 / Venus C Modbus register map

Default configuration

Protocol
RS485
Port
502
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first
Baud rate
115200
Parity
None
Data bits
8
Stop bits
1

This device has an RS-485 interface. Connect it directly on a serial port with Modbus RTU using the factory serial settings above, or reach it through a Modbus RTU-to-TCP gateway configured with those same settings.

Register map

AddressCountNameTypeUnitScaleAccess
303001
WiFi status
Binary sensor in the source (0 = not connected, 1 = connected).
UInt16-1R
303011
Bluetooth status
Bluetooth connectivity; the source prints no value meanings.
UInt16-1R
303021
Cloud status
Binary sensor in the source (0 = not connected, 1 = connected).
UInt16-1R
303031
WiFi signal strength
Raw value is the positive magnitude; scale -1 makes it a dBm reading.
UInt16dBm-1R
308006
Communication module firmware
12-character string across six registers.
Ascii-1R
3100010
Device name
20-character string across ten registers.
Ascii-1R
311001
Software version
Scale 0.01, per the source's definition.
UInt16-0.01R
311011
EMS firmware version
Values of 1000 and above carry one decimal in the last digit (1573 = 157.3); smaller values are whole numbers. That is how the source's integration formats the register.
UInt16-1R
311021
BMS firmware version
UInt16-1R
3120010
Serial number
20-character string across ten registers.
Ascii-1R
321001
Battery voltage
UInt16V0.01R
321011
Battery current
The sources document no sign convention.
Int16A0.01R
321022
Battery power
32-bit on this generation; Gen 3 reports battery power as int16 at 30001. The sources document no sign convention.
Int32W1R
321041
Battery state of charge
Whole percent in the integration and in evcc; the Duravolt-branded protocol document prints 0.1 % (500 = 50 %). Gen 3 reports 0.1 % resolution at 34002.
UInt16%1R
321051
Battery total energy (capacity)
Called 'total stored energy' in the integration's register table but used as the capacity in its stored-energy calculation; the Duravolt-branded protocol document calls it 'battery total energy', with 2500 = 2.5 kWh as its example.
UInt16kWh0.001R
322001
AC voltage
UInt16V0.1R
322011
AC current
int16 in the integration, u16 in the Duravolt-branded protocol document.
Int16A0.01R
322022
AC power
Positive = feeding power into the grid (the Duravolt-branded protocol document). evcc's Gen 2 path decodes it as int32 too; Gen 3 uses int16 at 30006.
Int32W1R
322041
AC frequency
Scale 0.01 on this generation; Gen 3 uses 0.1 at the same address. int16 in the integration, u16 in the Duravolt-branded protocol document.
Int16Hz0.01R
323001
Backup output voltage
UInt16V0.1R
323011
Backup output current
uint16, 0.01 A in both the integration and the Duravolt-branded protocol document. On Gen 3 the same address is reported to return the voltage value.
UInt16A0.01R
323022
Backup output power
Int32W1R
330002
Total charging energy
UInt32kWh0.01R
330022
Total discharging energy
Signed in the integration; evcc and the Duravolt-branded protocol document print an unsigned 32-bit value.
Int32kWh0.01R
330042
Daily charging energy
Restarts daily at 00:00.
UInt32kWh0.01R
330062
Daily discharging energy
Signed in the integration, unsigned in the Duravolt-branded protocol document. Restarts daily at 00:00.
Int32kWh0.01R
330082
Monthly charging energy
Restarts on the first of the month.
UInt32kWh0.01R
330102
Monthly discharging energy
Signed in the integration, unsigned in the Duravolt-branded protocol document. Restarts on the first of the month.
Int32kWh0.01R
350001
Internal temperature
Int16°C0.1R
350011
MOS1 temperature
Int16°C0.1R
350021
MOS2 temperature
Int16°C0.1R
350101
Maximum cell temperature
Whole degrees in the integration since a fix its history ties to BMS version 213; the Duravolt-branded protocol document (2024) prints 0.1 °C, so units on older BMS firmware may read ten times too high here. Gen 3 scales the same address by 0.1.
Int16°C1R
350111
Minimum cell temperature
Whole degrees in the integration since a fix its history ties to BMS version 213; the Duravolt-branded protocol document (2024) prints 0.1 °C, so units on older BMS firmware may read ten times too high here. Gen 3 scales the same address by 0.1.
Int16°C1R
351001
Inverter state
0 = sleep, 1 = standby, 2 = charge, 3 = discharge, 4 = backup mode, 5 = OTA upgrade, 6 = bypass (6 from the integration only).
UInt16-1R
351101
Battery charge voltage limit
From the Duravolt-branded protocol document only, which lists it as a read register; 100 mV per count.
UInt16V0.1R
351111
Battery charge current limit
From the Duravolt-branded protocol document only, which lists it as a read register; 100 mA per count.
UInt16A0.1R
351121
Battery discharge current limit
From the Duravolt-branded protocol document only, which lists it as a read register; 100 mA per count.
UInt16A0.1R
360001
Alarm status (word 36000)
Bits: 0 PLL abnormal restart, 1 overtemperature limit, 2 low-temperature limit, 3 fan abnormal warning, 4 low battery SOC warning, 5 output overcurrent warning, 6 abnormal line sequence detection. 1 = abnormal.
Binary-1R
360011
Alarm status (word 36001)
Bits within this register: 0 WiFi abnormal, 1 BLE abnormal, 2 network abnormal, 3 CT connection abnormal. The integration numbers them 16-19.
Binary-1R
361001
Fault status (word 36100)
Bits: 0 grid overvoltage, 1 grid undervoltage, 2 grid overfrequency, 3 grid underfrequency, 4 grid peak voltage, 5 current Dcover, 6 voltage Dcover (5 and 6 are the sources' own labels). 1 = abnormal.
Binary-1R
361011
Fault status (word 36101)
Bits within this register: 0 battery overvoltage, 1 battery undervoltage, 2 battery overcurrent, 3 battery low SOC, 4 battery communication failure, 5 BMS protect. The integration numbers them 16-21.
Binary-1R
361021
Fault status (word 36102)
Sources disagree. The integration numbers four faults 32-35 (inverter soft-start timeout, self-check failure, EEPROM failure, other system failure), which would be bits 0-3 here; the Duravolt-branded protocol document lists no bits for 36102 and puts them at 36103 bit 11 and 36104 bits 0-2.
Binary-1R
361031
Fault status (word 36103)
Bits within this register: 0 hardware bus overvoltage, 1 hardware output overcurrent, 2 hardware trans overcurrent (the sources' own label), 3 hardware battery overcurrent, 4 hardware protection, 5 output overcurrent, 6 high-voltage bus overvoltage, 7 high-voltage bus undervoltage, 8 overpower protection, 9 FSM abnormal, 10 overtemperature protection (48-58 in the integration); 11 inverter soft-start timeout in the Duravolt-branded protocol document only, see 36102.
Binary-1R
361041
Fault status (word 36104)
Bits within this register: 0 self-test fault, 1 EEPROM fault, 2 other system fault. From the Duravolt-branded protocol document only; the integration places these faults in 36102.
Binary-1R
370071
Maximum cell voltage
Int16V0.001R
370081
Minimum cell voltage
Int16V0.001R
411001
Modbus address
Reports the unit's Modbus slave address. Read-only here: the integration only reads it, and a write changes the address the unit answers on.
UInt16-1R
412001
Backup output switch
0 = backup output enabled, 1 = disabled.
UInt16-1RW
420001
RS-485 control mode
21930 (0x55AA) switches RS-485 control mode on, 21947 (0x55BB) switches it off. Registers 42000-42999 only take effect while it is on. According to evcc, switching it off lets the unit charge and discharge by itself again.
UInt16-1RW
420101
Force mode
0 = standby (stop), 1 = charge, 2 = discharge. Takes effect only after RS-485 control mode (42000) is switched on.
UInt16-1RW
420111
Charge/discharge target SoC
Writing a target of 10-100 % makes the unit charge or discharge to that SoC, stop there, and drop the forced charge/discharge mode (42010). Takes effect only after RS-485 control mode (42000) is switched on. 1 % per count in the integration and in the unit column of the Duravolt-branded protocol document, whose example (500 for 50 %) contradicts that column; the integration's README table prints 0-100 %.
UInt16%1RW
420201
Forced charge power setpoint
0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps. Takes effect only after RS-485 control mode (42000) is switched on. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers.
UInt16W1RW
420211
Forced discharge power setpoint
0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps. Takes effect only after RS-485 control mode (42000) is switched on. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers.
UInt16W1RW
430001
User work mode
0 = manual, 1 = anti-feed (self-consumption), 2 = trade mode (AI optimisation in the app). The source lists as a known issue that mode 2 may not read back correctly.
UInt16-1RW
440001
Charging cutoff SoC
Charging cutoff capacity, 80-100 % in 1 % steps, so the raw value runs 800-1000.
UInt16%0.1RW
440011
Discharging cutoff SoC
Discharging cutoff capacity, 12-30 % in 1 % steps, so the raw value runs 120-300.
UInt16%0.1RW
440021
Maximum charge power
Upper limit for charging, 0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps; evcc writes 0 to block charging. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers.
UInt16W1RW
440031
Maximum discharge power
Upper limit for discharging, 0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps; evcc writes 0 to block discharging and defaults to 800 W as the normal limit. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers.
UInt16W1RW
441001
Grid standard
0 = auto, 1 = EN50549, 2 = Netherlands, 3 = Germany, 4 = Austria, 5 = United Kingdom, 6 = Spain, 7 = Poland, 8 = Italy, 9 = China. Read-only here: a wrong grid code can defeat grid protection.
UInt16-1R
431001
Schedule 1 weekdays
Weekday bit mask for schedule 1: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days.
UInt16-1RW
431011
Schedule 1 start time
Start of schedule 1 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end.
UInt16-1RW
431021
Schedule 1 end time
End of schedule 1 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start.
UInt16-1RW
431031
Schedule 1 power setpoint
Power during schedule 1: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W.
Int16W1RW
431041
Schedule 1 enabled
1 = schedule 1 active, 0 = inactive.
UInt16-1RW
431051
Schedule 2 weekdays
Weekday bit mask for schedule 2: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days.
UInt16-1RW
431061
Schedule 2 start time
Start of schedule 2 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end.
UInt16-1RW
431071
Schedule 2 end time
End of schedule 2 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start.
UInt16-1RW
431081
Schedule 2 power setpoint
Power during schedule 2: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W.
Int16W1RW
431091
Schedule 2 enabled
1 = schedule 2 active, 0 = inactive.
UInt16-1RW
431101
Schedule 3 weekdays
Weekday bit mask for schedule 3: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days.
UInt16-1RW
431111
Schedule 3 start time
Start of schedule 3 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end.
UInt16-1RW
431121
Schedule 3 end time
End of schedule 3 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start.
UInt16-1RW
431131
Schedule 3 power setpoint
Power during schedule 3: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W.
Int16W1RW
431141
Schedule 3 enabled
1 = schedule 3 active, 0 = inactive.
UInt16-1RW
431151
Schedule 4 weekdays
Weekday bit mask for schedule 4: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days.
UInt16-1RW
431161
Schedule 4 start time
Start of schedule 4 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end.
UInt16-1RW
431171
Schedule 4 end time
End of schedule 4 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start.
UInt16-1RW
431181
Schedule 4 power setpoint
Power during schedule 4: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W.
Int16W1RW
431191
Schedule 4 enabled
1 = schedule 4 active, 0 = inactive.
UInt16-1RW
431201
Schedule 5 weekdays
Weekday bit mask for schedule 5: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days.
UInt16-1RW
431211
Schedule 5 start time
Start of schedule 5 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end.
UInt16-1RW
431221
Schedule 5 end time
End of schedule 5 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start.
UInt16-1RW
431231
Schedule 5 power setpoint
Power during schedule 5: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W.
Int16W1RW
431241
Schedule 5 enabled
1 = schedule 5 active, 0 = inactive.
UInt16-1RW
431251
Schedule 6 weekdays
Weekday bit mask for schedule 6: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days.
UInt16-1RW
431261
Schedule 6 start time
Start of schedule 6 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end.
UInt16-1RW
431271
Schedule 6 end time
End of schedule 6 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start.
UInt16-1RW
431281
Schedule 6 power setpoint
Power during schedule 6: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W.
Int16W1RW
431291
Schedule 6 enabled
1 = schedule 6 active, 0 = inactive.
UInt16-1RW

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Combined registers

  • Round-trip efficiency, all time (calculated)Holding registers 33002 / Holding registers 33000 (%)Total discharging energy divided by total charging energy, as the source's round-trip efficiency sensor computes it; scale 100 turns the ratio into percent.

Notes

Sources, retrieved 2026-11-23. (1) Community, secondary: the Marstek Venus Modbus integration for Home Assistant, https://github.com/ViperRNMC/marstek_venus_modbus, commit cb5a241 (2026-10-26), registers/e_v12.yaml and README.md; one file for Venus E v1 and v2. (2) https://github.com/evcc-io/evcc, commit c95e435 (2026-11-23), templates/definition/meter/marstek-venus-e.yaml and marstek-batterymode.tpl: AC power at 32202, SoC at 32104, unit ID 1, 115200 8N1. Its help text counts Venus E, Venus E Gen 2.0 and Venus C as generation 2, hence Venus C here; (1) does not mention Venus C. (3) 'Duravolt Plug-In thuisbatterij 485 protocol' v1.1 (2024), https://duravolt.nl/wp-content/uploads/Duravolt-Plug-in-Battery-Modbus.pdf, SHA-256 24101ff1c42ffb92c0c1e9a5cc9f852307016f5384b1dd53dee5366f44eadb79: a Marstek distributor's document for the 2.56 kWh battery sold as 'by Marstek' (page archived 2026-05-12), supplied with Marstek's manual for MST-BIE2.5-2500 and MST-BIE5-2500. It prints address 1, 115200 8N1, types, units and write ranges. No Modbus document under Marstek's own name was found; its Device Local API Rev 3.1.2 is JSON-RPC. They disagree on the scale of 32104, 35010 and 35011, the signedness of 32201 and the discharging counters, the example for 42011 and four fault bits (36102, 36103, 36104). The rows say so and follow (1) where it defines them; the AC power sign and write effects come from (3). Transport: RS-485 behind an RTU-to-TCP gateway, port 502 a declared default. Addresses as passed to the source's Modbus client (zero_based); 32-bit values high word first, text high byte first, as it decodes them. Left out: BLE MAC address, discharge-limit sensor 41010 (no meanings), factory reset. 44100 and 41100 are read-only here although (3) allows writes. Nothing here was tested on hardware by us.