  "spec_version": 1,
  "slug": "marstek-venus-e-gen1-gen2",
  "manufacturer": "Marstek",
  "model": "Venus E Gen 1 / Venus E Gen 2 / Venus C",
  "category": "Home battery",
  "supplier_url": "https://marstekenergy.com/collections/marstek-venus-series",
  "default_configuration": {
    "protocol": "modbus_tcp",
    "port": 502,
    "unit_id": 1,
    "addressing": "zero_based",
    "byte_order": "BigEndian",
    "word_order": "HighFirst",
    "native_interface": "rs485",
    "serial": {
      "baud_rate": 115200,
      "parity": "None",
      "data_bits": 8,
      "stop_bits": 1
    }
  },
  "coils": [],
  "discrete_inputs": [],
  "input_registers": [],
  "holding_registers": [
    {
      "address": 30300,
      "count": 1,
      "name": "WiFi status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Binary sensor in the source (0 = not connected, 1 = connected)."
    },
    {
      "address": 30301,
      "count": 1,
      "name": "Bluetooth status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bluetooth connectivity; the source prints no value meanings."
    },
    {
      "address": 30302,
      "count": 1,
      "name": "Cloud status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Binary sensor in the source (0 = not connected, 1 = connected)."
    },
    {
      "address": 30303,
      "count": 1,
      "name": "WiFi signal strength",
      "data_type": "UInt16",
      "units": "dBm",
      "scale_factor": -1,
      "offset": 0,
      "access": "R",
      "description": "Raw value is the positive magnitude; scale -1 makes it a dBm reading."
    },
    {
      "address": 30800,
      "count": 6,
      "name": "Communication module firmware",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "12-character string across six registers."
    },
    {
      "address": 31000,
      "count": 10,
      "name": "Device name",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "20-character string across ten registers."
    },
    {
      "address": 31100,
      "count": 1,
      "name": "Software version",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Scale 0.01, per the source's definition."
    },
    {
      "address": 31101,
      "count": 1,
      "name": "EMS firmware version",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Values of 1000 and above carry one decimal in the last digit (1573 = 157.3); smaller values are whole numbers. That is how the source's integration formats the register."
    },
    {
      "address": 31102,
      "count": 1,
      "name": "BMS firmware version",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 31200,
      "count": 10,
      "name": "Serial number",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "20-character string across ten registers."
    },
    {
      "address": 32100,
      "count": 1,
      "name": "Battery voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 32101,
      "count": 1,
      "name": "Battery current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "The sources document no sign convention."
    },
    {
      "address": 32102,
      "count": 2,
      "name": "Battery power",
      "data_type": "Int32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "32-bit on this generation; Gen 3 reports battery power as int16 at 30001. The sources document no sign convention."
    },
    {
      "address": 32104,
      "count": 1,
      "name": "Battery state of charge",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Whole percent in the integration and in evcc; the Duravolt-branded protocol document prints 0.1 % (500 = 50 %). Gen 3 reports 0.1 % resolution at 34002."
    },
    {
      "address": 32105,
      "count": 1,
      "name": "Battery total energy (capacity)",
      "data_type": "UInt16",
      "units": "kWh",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R",
      "description": "Called 'total stored energy' in the integration's register table but used as the capacity in its stored-energy calculation; the Duravolt-branded protocol document calls it 'battery total energy', with 2500 = 2.5 kWh as its example."
    },
    {
      "address": 32200,
      "count": 1,
      "name": "AC voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 32201,
      "count": 1,
      "name": "AC current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "int16 in the integration, u16 in the Duravolt-branded protocol document."
    },
    {
      "address": 32202,
      "count": 2,
      "name": "AC power",
      "data_type": "Int32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Positive = feeding power into the grid (the Duravolt-branded protocol document). evcc's Gen 2 path decodes it as int32 too; Gen 3 uses int16 at 30006."
    },
    {
      "address": 32204,
      "count": 1,
      "name": "AC frequency",
      "data_type": "Int16",
      "units": "Hz",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Scale 0.01 on this generation; Gen 3 uses 0.1 at the same address. int16 in the integration, u16 in the Duravolt-branded protocol document."
    },
    {
      "address": 32300,
      "count": 1,
      "name": "Backup output voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 32301,
      "count": 1,
      "name": "Backup output current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "uint16, 0.01 A in both the integration and the Duravolt-branded protocol document. On Gen 3 the same address is reported to return the voltage value."
    },
    {
      "address": 32302,
      "count": 2,
      "name": "Backup output power",
      "data_type": "Int32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 33000,
      "count": 2,
      "name": "Total charging energy",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 33002,
      "count": 2,
      "name": "Total discharging energy",
      "data_type": "Int32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Signed in the integration; evcc and the Duravolt-branded protocol document print an unsigned 32-bit value."
    },
    {
      "address": 33004,
      "count": 2,
      "name": "Daily charging energy",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Restarts daily at 00:00."
    },
    {
      "address": 33006,
      "count": 2,
      "name": "Daily discharging energy",
      "data_type": "Int32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Signed in the integration, unsigned in the Duravolt-branded protocol document. Restarts daily at 00:00."
    },
    {
      "address": 33008,
      "count": 2,
      "name": "Monthly charging energy",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Restarts on the first of the month."
    },
    {
      "address": 33010,
      "count": 2,
      "name": "Monthly discharging energy",
      "data_type": "Int32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Signed in the integration, unsigned in the Duravolt-branded protocol document. Restarts on the first of the month."
    },
    {
      "address": 35000,
      "count": 1,
      "name": "Internal temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 35001,
      "count": 1,
      "name": "MOS1 temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 35002,
      "count": 1,
      "name": "MOS2 temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 35010,
      "count": 1,
      "name": "Maximum cell temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Whole degrees in the integration since a fix its history ties to BMS version 213; the Duravolt-branded protocol document (2024) prints 0.1 °C, so units on older BMS firmware may read ten times too high here. Gen 3 scales the same address by 0.1."
    },
    {
      "address": 35011,
      "count": 1,
      "name": "Minimum cell temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Whole degrees in the integration since a fix its history ties to BMS version 213; the Duravolt-branded protocol document (2024) prints 0.1 °C, so units on older BMS firmware may read ten times too high here. Gen 3 scales the same address by 0.1."
    },
    {
      "address": 35100,
      "count": 1,
      "name": "Inverter state",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = sleep, 1 = standby, 2 = charge, 3 = discharge, 4 = backup mode, 5 = OTA upgrade, 6 = bypass (6 from the integration only)."
    },
    {
      "address": 35110,
      "count": 1,
      "name": "Battery charge voltage limit",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "From the Duravolt-branded protocol document only, which lists it as a read register; 100 mV per count."
    },
    {
      "address": 35111,
      "count": 1,
      "name": "Battery charge current limit",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "From the Duravolt-branded protocol document only, which lists it as a read register; 100 mA per count."
    },
    {
      "address": 35112,
      "count": 1,
      "name": "Battery discharge current limit",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "From the Duravolt-branded protocol document only, which lists it as a read register; 100 mA per count."
    },
    {
      "address": 36000,
      "count": 1,
      "name": "Alarm status (word 36000)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bits: 0 PLL abnormal restart, 1 overtemperature limit, 2 low-temperature limit, 3 fan abnormal warning, 4 low battery SOC warning, 5 output overcurrent warning, 6 abnormal line sequence detection. 1 = abnormal."
    },
    {
      "address": 36001,
      "count": 1,
      "name": "Alarm status (word 36001)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bits within this register: 0 WiFi abnormal, 1 BLE abnormal, 2 network abnormal, 3 CT connection abnormal. The integration numbers them 16-19."
    },
    {
      "address": 36100,
      "count": 1,
      "name": "Fault status (word 36100)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bits: 0 grid overvoltage, 1 grid undervoltage, 2 grid overfrequency, 3 grid underfrequency, 4 grid peak voltage, 5 current Dcover, 6 voltage Dcover (5 and 6 are the sources' own labels). 1 = abnormal."
    },
    {
      "address": 36101,
      "count": 1,
      "name": "Fault status (word 36101)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bits within this register: 0 battery overvoltage, 1 battery undervoltage, 2 battery overcurrent, 3 battery low SOC, 4 battery communication failure, 5 BMS protect. The integration numbers them 16-21."
    },
    {
      "address": 36102,
      "count": 1,
      "name": "Fault status (word 36102)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Sources disagree. The integration numbers four faults 32-35 (inverter soft-start timeout, self-check failure, EEPROM failure, other system failure), which would be bits 0-3 here; the Duravolt-branded protocol document lists no bits for 36102 and puts them at 36103 bit 11 and 36104 bits 0-2."
    },
    {
      "address": 36103,
      "count": 1,
      "name": "Fault status (word 36103)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bits within this register: 0 hardware bus overvoltage, 1 hardware output overcurrent, 2 hardware trans overcurrent (the sources' own label), 3 hardware battery overcurrent, 4 hardware protection, 5 output overcurrent, 6 high-voltage bus overvoltage, 7 high-voltage bus undervoltage, 8 overpower protection, 9 FSM abnormal, 10 overtemperature protection (48-58 in the integration); 11 inverter soft-start timeout in the Duravolt-branded protocol document only, see 36102."
    },
    {
      "address": 36104,
      "count": 1,
      "name": "Fault status (word 36104)",
      "data_type": "Binary",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bits within this register: 0 self-test fault, 1 EEPROM fault, 2 other system fault. From the Duravolt-branded protocol document only; the integration places these faults in 36102."
    },
    {
      "address": 37007,
      "count": 1,
      "name": "Maximum cell voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 37008,
      "count": 1,
      "name": "Minimum cell voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 41100,
      "count": 1,
      "name": "Modbus address",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Reports the unit's Modbus slave address. Read-only here: the integration only reads it, and a write changes the address the unit answers on."
    },
    {
      "address": 41200,
      "count": 1,
      "name": "Backup output switch",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0 = backup output enabled, 1 = disabled."
    },
    {
      "address": 42000,
      "count": 1,
      "name": "RS-485 control mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "21930 (0x55AA) switches RS-485 control mode on, 21947 (0x55BB) switches it off. Registers 42000-42999 only take effect while it is on. According to evcc, switching it off lets the unit charge and discharge by itself again."
    },
    {
      "address": 42010,
      "count": 1,
      "name": "Force mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0 = standby (stop), 1 = charge, 2 = discharge. Takes effect only after RS-485 control mode (42000) is switched on."
    },
    {
      "address": 42011,
      "count": 1,
      "name": "Charge/discharge target SoC",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Writing a target of 10-100 % makes the unit charge or discharge to that SoC, stop there, and drop the forced charge/discharge mode (42010). Takes effect only after RS-485 control mode (42000) is switched on. 1 % per count in the integration and in the unit column of the Duravolt-branded protocol document, whose example (500 for 50 %) contradicts that column; the integration's README table prints 0-100 %."
    },
    {
      "address": 42020,
      "count": 1,
      "name": "Forced charge power setpoint",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps. Takes effect only after RS-485 control mode (42000) is switched on. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers."
    },
    {
      "address": 42021,
      "count": 1,
      "name": "Forced discharge power setpoint",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps. Takes effect only after RS-485 control mode (42000) is switched on. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers."
    },
    {
      "address": 43000,
      "count": 1,
      "name": "User work mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0 = manual, 1 = anti-feed (self-consumption), 2 = trade mode (AI optimisation in the app). The source lists as a known issue that mode 2 may not read back correctly."
    },
    {
      "address": 44000,
      "count": 1,
      "name": "Charging cutoff SoC",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Charging cutoff capacity, 80-100 % in 1 % steps, so the raw value runs 800-1000."
    },
    {
      "address": 44001,
      "count": 1,
      "name": "Discharging cutoff SoC",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Discharging cutoff capacity, 12-30 % in 1 % steps, so the raw value runs 120-300."
    },
    {
      "address": 44002,
      "count": 1,
      "name": "Maximum charge power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Upper limit for charging, 0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps; evcc writes 0 to block charging. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers."
    },
    {
      "address": 44003,
      "count": 1,
      "name": "Maximum discharge power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Upper limit for discharging, 0-2500 W in both the Duravolt-branded protocol document and the integration, which uses 50 W steps; evcc writes 0 to block discharging and defaults to 800 W as the normal limit. 2500 W is also the rated power of the MST-BIE2.5-2500 and MST-BIE5-2500 units the document covers."
    },
    {
      "address": 44100,
      "count": 1,
      "name": "Grid standard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = auto, 1 = EN50549, 2 = Netherlands, 3 = Germany, 4 = Austria, 5 = United Kingdom, 6 = Spain, 7 = Poland, 8 = Italy, 9 = China. Read-only here: a wrong grid code can defeat grid protection."
    },
    {
      "address": 43100,
      "count": 1,
      "name": "Schedule 1 weekdays",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Weekday bit mask for schedule 1: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days."
    },
    {
      "address": 43101,
      "count": 1,
      "name": "Schedule 1 start time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Start of schedule 1 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end."
    },
    {
      "address": 43102,
      "count": 1,
      "name": "Schedule 1 end time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "End of schedule 1 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start."
    },
    {
      "address": 43103,
      "count": 1,
      "name": "Schedule 1 power setpoint",
      "data_type": "Int16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Power during schedule 1: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W."
    },
    {
      "address": 43104,
      "count": 1,
      "name": "Schedule 1 enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "1 = schedule 1 active, 0 = inactive."
    },
    {
      "address": 43105,
      "count": 1,
      "name": "Schedule 2 weekdays",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Weekday bit mask for schedule 2: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days."
    },
    {
      "address": 43106,
      "count": 1,
      "name": "Schedule 2 start time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Start of schedule 2 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end."
    },
    {
      "address": 43107,
      "count": 1,
      "name": "Schedule 2 end time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "End of schedule 2 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start."
    },
    {
      "address": 43108,
      "count": 1,
      "name": "Schedule 2 power setpoint",
      "data_type": "Int16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Power during schedule 2: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W."
    },
    {
      "address": 43109,
      "count": 1,
      "name": "Schedule 2 enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "1 = schedule 2 active, 0 = inactive."
    },
    {
      "address": 43110,
      "count": 1,
      "name": "Schedule 3 weekdays",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Weekday bit mask for schedule 3: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days."
    },
    {
      "address": 43111,
      "count": 1,
      "name": "Schedule 3 start time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Start of schedule 3 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end."
    },
    {
      "address": 43112,
      "count": 1,
      "name": "Schedule 3 end time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "End of schedule 3 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start."
    },
    {
      "address": 43113,
      "count": 1,
      "name": "Schedule 3 power setpoint",
      "data_type": "Int16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Power during schedule 3: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W."
    },
    {
      "address": 43114,
      "count": 1,
      "name": "Schedule 3 enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "1 = schedule 3 active, 0 = inactive."
    },
    {
      "address": 43115,
      "count": 1,
      "name": "Schedule 4 weekdays",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Weekday bit mask for schedule 4: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days."
    },
    {
      "address": 43116,
      "count": 1,
      "name": "Schedule 4 start time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Start of schedule 4 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end."
    },
    {
      "address": 43117,
      "count": 1,
      "name": "Schedule 4 end time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "End of schedule 4 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start."
    },
    {
      "address": 43118,
      "count": 1,
      "name": "Schedule 4 power setpoint",
      "data_type": "Int16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Power during schedule 4: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W."
    },
    {
      "address": 43119,
      "count": 1,
      "name": "Schedule 4 enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "1 = schedule 4 active, 0 = inactive."
    },
    {
      "address": 43120,
      "count": 1,
      "name": "Schedule 5 weekdays",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Weekday bit mask for schedule 5: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days."
    },
    {
      "address": 43121,
      "count": 1,
      "name": "Schedule 5 start time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Start of schedule 5 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end."
    },
    {
      "address": 43122,
      "count": 1,
      "name": "Schedule 5 end time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "End of schedule 5 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start."
    },
    {
      "address": 43123,
      "count": 1,
      "name": "Schedule 5 power setpoint",
      "data_type": "Int16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Power during schedule 5: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W."
    },
    {
      "address": 43124,
      "count": 1,
      "name": "Schedule 5 enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "1 = schedule 5 active, 0 = inactive."
    },
    {
      "address": 43125,
      "count": 1,
      "name": "Schedule 6 weekdays",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Weekday bit mask for schedule 6: 1 Monday, 2 Tuesday, 4 Wednesday, 8 Thursday, 16 Friday, 32 Saturday, 64 Sunday, added together for several days."
    },
    {
      "address": 43126,
      "count": 1,
      "name": "Schedule 6 start time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Start of schedule 6 as an HHMM number: 800 = 08:00. The integration accepts 0-2358; the start must be earlier than the end."
    },
    {
      "address": 43127,
      "count": 1,
      "name": "Schedule 6 end time",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "End of schedule 6 as an HHMM number: 1730 = 17:30. The integration accepts 1-2359; the end must be later than the start."
    },
    {
      "address": 43128,
      "count": 1,
      "name": "Schedule 6 power setpoint",
      "data_type": "Int16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Power during schedule 6: negative = charge, positive = discharge, -1 = self-consumption. Allowed range -2500 to 2500 W; the integration's README lists -100 to -2500 W and 100 to 2500 W."
    },
    {
      "address": 43129,
      "count": 1,
      "name": "Schedule 6 enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "1 = schedule 6 active, 0 = inactive."
    }
  ],
  "combined_registers": [
    {
      "id": "round-trip-efficiency-total",
      "label": "Round-trip efficiency, all time (calculated)",
      "operator": "/",
      "operand_a": {
        "register_type": "holding_registers",
        "register_address": 33002
      },
      "operand_b": {
        "register_type": "holding_registers",
        "register_address": 33000
      },
      "units": "%",
      "scale_factor": 100,
      "offset": 0,
      "description": "Total discharging energy divided by total charging energy, as the source's round-trip efficiency sensor computes it; scale 100 turns the ratio into percent."
    }
  ],
  "notes": "Sources, retrieved 2026-11-23. (1) Community, secondary: the Marstek Venus Modbus integration for Home Assistant, https://github.com/ViperRNMC/marstek_venus_modbus, commit cb5a241 (2026-10-26), registers/e_v12.yaml and README.md; one file for Venus E v1 and v2. (2) https://github.com/evcc-io/evcc, commit c95e435 (2026-11-23), templates/definition/meter/marstek-venus-e.yaml and marstek-batterymode.tpl: AC power at 32202, SoC at 32104, unit ID 1, 115200 8N1. Its help text counts Venus E, Venus E Gen 2.0 and Venus C as generation 2, hence Venus C here; (1) does not mention Venus C. (3) 'Duravolt Plug-In thuisbatterij 485 protocol' v1.1 (2024), https://duravolt.nl/wp-content/uploads/Duravolt-Plug-in-Battery-Modbus.pdf, SHA-256 24101ff1c42ffb92c0c1e9a5cc9f852307016f5384b1dd53dee5366f44eadb79: a Marstek distributor's document for the 2.56 kWh battery sold as 'by Marstek' (page archived 2026-05-12), supplied with Marstek's manual for MST-BIE2.5-2500 and MST-BIE5-2500. It prints address 1, 115200 8N1, types, units and write ranges. No Modbus document under Marstek's own name was found; its Device Local API Rev 3.1.2 is JSON-RPC. They disagree on the scale of 32104, 35010 and 35011, the signedness of 32201 and the discharging counters, the example for 42011 and four fault bits (36102, 36103, 36104). The rows say so and follow (1) where it defines them; the AC power sign and write effects come from (3). Transport: RS-485 behind an RTU-to-TCP gateway, port 502 a declared default. Addresses as passed to the source's Modbus client (zero_based); 32-bit values high word first, text high byte first, as it decodes them. Left out: BLE MAC address, discharge-limit sensor 41010 (no meanings), factory reset. 44100 and 41100 are read-only here although (3) allows writes. Nothing here was tested on hardware by us."
}