SMT100 soil moisture and temperature sensor (RS485 Modbus variant) Modbus register map

Serial device: in Modbus Connect, choose “Add to existing device” and pick the serial (RTU) device you created on your COM port.

Default configuration

Protocol
Modbus RTU over RS-485
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first
Baud rate
9600
Parity
Even
Data bits
8
Stop bits
1

To read this device over Modbus RTU in Modbus Connect:

  1. In Modbus Connect, add a serial (RTU) device on your COM port with the serial settings and unit ID shown above.
  2. Click Add to Modbus Connect (or open the downloaded JSON), choose “Add to existing device” and pick that serial device. Its registers, byte order and word order are added; the serial device keeps its own line settings.

The “Add device” tab creates a Modbus TCP device (IP address and port), so use it only when you reach this device through a Modbus RTU-to-TCP gateway set to the serial settings above.

Register map

AddressCountNameTypeUnitScaleAccess
01
Soil temperature
16-bit unsigned. The application note's equation is temperature [°C] = (raw / 100) - 100; its worked frame reads 0x31FD = 12797 = 27.97 °C. Stored here as scale 0.01 with offset -100.
UInt16°C0.01 (offset -100)R
11
Soil moisture (volumetric water content)
16-bit unsigned. Soil moisture [vol.%] = raw / 100; the worked frame reads 0x0D70 = 3440 = 34.40 vol.%.
UInt16vol.%0.01R
21
Permittivity (relative dielectric constant)
16-bit unsigned. The worked frame reads 0x05F0 = 1520 = DK 15.20, so the raw value carries two decimals.
UInt16-0.01R
31
Raw measurement counts
16-bit unsigned raw signal (the worked frame reads 0x4ECE = 20174 counts). Not calibrated and not used in normal operation; the vendor provides it for scientific work and special calibrations.
UInt16-1R
41
Modbus slave address
Writing a new address here changes the sensor's slave address (the worked frame writes 2). The sensor also always answers to the fixed broadcast address 253, which cannot be changed; connect only one sensor to the bus when using it.
UInt16-1RW

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

Source: TRUEBNER GmbH 'SMT100 Modbus Quickstart Guide', Application Note AN002 (07/2021), vendor-hosted PDF at https://www.truebner.de/assets/download/AN002.pdf (SHA-256 7a6406cef72fffe9b6b756e0be8b7a5ef5e5a57dfd8e0d173dbc3f3f19172dc5), section 'Modbus configuration' plus the five worked request/response frames. The SMT100 product manual (Manual_SMT100_V1.0) adds that the baud rate is fixed at 9600 and that the sensor is ordered either with the ASCII/T-Bus interface or with Modbus. Factory serial settings from AN002: 9600 baud, 8 data bits, even parity, 1 stop bit; slave address configurable 1...247 with a fixed broadcast address of 253 - no factory slave address is printed in either document, so the seed stores 1 as a verify-on-site placeholder - every worked frame in the application note uses address 1. Addressing: the note prints the register numbers and the frame's start address as 0x0000 for temperature, 0x0001 for soil moisture, 0x0002 for permittivity, 0x0003 for the counts and 0x0004 for the address register, so the seed is zero_based. All values are single 16-bit registers; the conversion equations are applied through scale_factor and offset. The recommended minimum timeout between a read request and its answer is 500 ms because the read starts a measurement. Only the four measurement registers and the address register are documented; the product manual's ASCII/T-Bus command set does not apply in Modbus mode.