Peblar · EV charger

Home / Home Plus / Business (also ChargeLine Home / Business) Modbus register map

Default configuration

Protocol
Modbus TCP
Port
502
Unit ID
1
Addressing
0-based
Byte order
Big endian
Word order
High word first

Register map

AddressCountNameTypeUnitScaleAccess
300082
Power phase 1
Instantaneous power of phase 1.
Int32W1R
300102
Power phase 2
Instantaneous power of phase 2.
Int32W1R
300122
Power phase 3
Instantaneous power of phase 3.
Int32W1R
300142
Power total
Instantaneous power of all phases combined.
Int32W1R
300162
Voltage phase 1
Instantaneous voltage on phase 1.
Int32V1R
300182
Voltage phase 2
Instantaneous voltage on phase 2.
Int32V1R
300202
Voltage phase 3
Instantaneous voltage on phase 3.
Int32V1R
300222
Current phase 1
Instantaneous current of phase 1.
Int32mA1R
300242
Current phase 2
Instantaneous current of phase 2.
Int32mA1R
300262
Current phase 3
Instantaneous current of phase 3.
Int32mA1R
3005012
Product serial number
Serial number as a 24-byte string.
Ascii-1R
3006212
Product number
Product number as a 24-byte string.
Ascii-1R
3007412
Firmware version
Firmware identifier as a 24-byte string.
Ascii-1R
300862
WLAN signal strength
Int32dBm1R
300882
Cellular signal strength
Int32dBm1R
300902
Uptime
Time since the last boot.
UInt32s1R
300921
Phase count
Number of physically connected phases, either defined by the hardware or configured during installation.
UInt16-1R
300931
Independent relays
0 = L1/2/3 and N on a single relay, 1 = L1/N and L2/L3 on separate relays (L1 can then be used alone on a three-phase system).
UInt16-1R
301001
Active warning 1
Warning number, 0 when inactive; several warnings can be active at once.
UInt16-1R
301011
Active warning 2
Warning number, 0 when inactive.
UInt16-1R
301021
Active warning 3
Warning number, 0 when inactive.
UInt16-1R
301031
Active warning 4
Warning number, 0 when inactive.
UInt16-1R
301041
Active warning 5
Warning number, 0 when inactive.
UInt16-1R
301051
Active error 1
Error number, 0 when inactive; several errors can be active at once.
UInt16-1R
301061
Active error 2
Error number, 0 when inactive.
UInt16-1R
301071
Active error 3
Error number, 0 when inactive.
UInt16-1R
301081
Active error 4
Error number, 0 when inactive.
UInt16-1R
301091
Active error 5
Error number, 0 when inactive.
UInt16-1R
301101
CP state
Control-pilot level: A = no EV connected, B = EV connected but suspended, C = EV connected and charging, D = as C with ventilation requested, E = error (short to PE or powered off), F = fault, I = invalid CP level measured, U = unknown.
UInt16-1R
301111
Lock state
0 = unlocked, 1 = locked. Stays 0 on fixed-cable systems.
Int16-1R
301121
Charge current limit source
Active limiting source: 0 = unknown, 1 = fixed cable, 2 = thermal, 3 = configuration limit, 4 = dynamic load balancing, 5 = group load balancing, 6 = user cable, 7 = overcurrent protection, 8 = hardware limit, 9 = power factor, 10 = OCPP smart charging, 11 = phase imbalance monitoring, 12 = local scheduled charging, 13 = solar charging, 14 = current slider, 15 = local REST API, 16 = local Modbus API, 17 = power limit input, 18 = household power limit, 19 = reserved, 20 = internal power limiter.
UInt16-1R
301132
Charge current limit actual
Current actually communicated to the vehicle: the lowest of all limiting sources.
UInt32mA1R
301221
Hardware identifier
Reserved for future use, reads 0.
UInt16-1R
301231
Modbus API version major
Major API version, increased on breaking changes. This map follows major version 1.
UInt16-1R
301241
Modbus API version minor
Minor API version, increased when a register is added. This document describes minor version 0.
UInt16-1R

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

Source: Peblar (Prodrive Technologies), "Developer Information - Modbus API", published on the vendor's own developer site at the supplier_url. That page is Peblar's developer information application: it renders client-side and the Modbus API reference, including the register tables used here, is part of the page's bundled content - the former deep link /modbus-api now answers 404 while the site root still serves the same document. The page fixes the transport: the Modbus TCP server uses port 502, word and byte order are big endian, the server is supported from firmware 1.6 onwards and has to be enabled in the charger's advanced web settings, either ReadOnly or ReadWrite (only ReadWrite allows control of the charge current and forcing single-phase charging). The register numbers of that page (40000 for holding registers, 30000 for input registers) are used unchanged as wire addresses here and declared zero_based; evcc's peblar driver confirms that reading, it addresses the same 30000/40000 numbers directly and cites this same page as its source. The vendor page documents no slave address: the unit ID 1 above is a placeholder taken from the evcc peblar template (secondary source), not a value from any document, and the user must set the charger's own address. Left out on purpose: EnergyTotal (30000) and SessionEnergy (30004), both int64 over four registers, because this schema has no 64-bit integer type. The 24-byte strings are 12 registers each. Charging caveats quoted from the page: pausing via a current limit below 6 A should not happen more than three times per rolling ten minutes because the on-board relays are stressed, and the fallback current of 40052 overrules the charge current limit after the alive timeout of 40050 expires.