All devices

MENNEKES · EV charger

AMTRON Compact 2.0s / 4You 300 / Start 2.0s Modbus register map

Default configuration

Protocol
RS485
Port
502
Unit ID
50
Addressing
0-based
Byte order
Big endian
Word order
High word first
Baud rate
57600
Parity
None
Data bits
8
Stop bits
2

This device has an RS-485 interface. Reach it through a Modbus RTU-to-TCP gateway, configured with the factory serial settings above.

Register map

AddressCountNameTypeUnitScaleAccess
01
Modbus register layout version
0x0000. Internal Modbus register layout version: v01.00 = 0x0100, v01.03 = 0x0103. Not the firmware version.
UInt16-1R
18
Firmware version
0x0001, 16 bytes.
Ascii-1R
198
Serial number
0x0013, 16 bytes.
Ascii-1R
278
MENNEKES article number
0x001B, 16 bytes. Article number as on the type plate, e.g. 1313201205 for an AMTRON 4You 310 11.
Ascii-1R
2561
EVSE state
0x0100. 0 = not initialized, 1 = idle (no EV connected), 2 = EV connected (no charging current signalled), 3 = preconditions valid but not charging yet, 4 = ready to charge, 5 = charging, 6 = error, 7 = service mode.
UInt16-1R
2571
Authorization status
0x0101. 0 = not used (idle), 1 = authorized (charging released), 2 = not authorized (charging not released). Covers RFID and energy-manager authorization.
UInt16-1R
2581
Downgrade
0x0102. External downgrade signal: 0 = not relevant (no EV connected), 1 = current not downgraded, 2 = current downgraded.
UInt16-1R
2591
Phase rotation
0x0103. Order of the connected phases, relevant for load management: 0 = L1-L2-L3, 1 = L2-L3-L1, 2 = L3-L1-L2.
UInt16-1R
2641
CP state
0x0108. Control-pilot state between EVSE and EV: 0 = init, 10 = A1 (no EV), 11 = B1, 12 = C1, 13 = D1, 14/15 = E/F (error), 26 = A2, 27 = B2, 28 = C2, 29 = D2.
UInt16-1R
2762
Signalled current
0x0114. Charging current signalled to the EV on the CP line, after any active downgrade.
Float32A1R
7682
Downgrade current
0x0300-0x0301. Charging-current limitation while the external downgrade signal is active.
Float32A1R
7702
Charging current, energy manager
0x0302-0x0303. The EMS current setpoint. 0 = no limitation, the EVSE signals its maximum (16/32 A); 0.01 to 5.99 A = invalid, the EVSE signals 0 A; 6 A and above = valid, bounded by the station's own limit. Values above the configured maximum are limited automatically.
Float32A1RW
7722
Maximal current, house (DIP)
0x0304-0x0305. Installation current from DIP switches 6-8 on bank S2: 0 = 63 A, 1 = 50 A, 2 = 40 A, 3 = 35 A, 4 = 32 A, 5 = 25 A, 6 = 20 A, 7 = 16 A.
Float32A1R
7742
Maximal EVSE current
0x0306-0x0307. Maximum current of the station as configured during installation: 0 = 32 A on a 22 kW unit and 16 A on an 11 kW unit, then 1 = 25 A/16 A, 2 = 20 A/16 A, 3 = 16 A, 4 = 13 A, 5 = 10 A, 6 = 6 A.
Float32A1R
7781
Phase switching mode
0x030A. 0 = solar only, 1 phase; 1 = solar only, 3 phases; 2 = solar dynamic, 1 or 3 phases (internal solar algorithm).
UInt16-1R
7801
Phase options, hardware
0x030C. 0 = hardware 1 phase only, 1 = hardware 3 phases only, 2 = hardware 1 or 3 phases (phase switching possible).
UInt16-1R
7811
Cable lock setting
0x030D. 0 = permanent cable lock not enabled or unavailable, 1 = enabled.
UInt16-1R
7821
Energy manager fallback current
0x030E. Behaviour when the energy-manager heartbeat is missing during a session: 0 = fallback handling disabled (continue with the last values), 1 = fallback handling enabled (pause charging on heartbeat timeout), 6 to 32 = fallback current in A.
UInt16A1R
7831
Grid imbalance
0x030F. 0 = disabled, 1 = enabled.
UInt16-1R
7841
Grid imbalance threshold
0x0310. Threshold of the grid-imbalance detection, documented range 10 to 30 A.
UInt16A1R
7851
Grid phases connected
0x0311. Number of phases connected to the grid: 0 = L1, 2 = L1, L2 and L3.
UInt16-1R
7861
Authorization
0x0312. 0 = disabled, 1 = enabled.
UInt16-1R
7871
Solar supported charging current (Sunshine+)
0x0313. Minimum charging current in the solar-supported charging mode, 6 to 32 A.
UInt16A1R
7881
Phase switching pause
0x0314. Time between a phase switch from 1 to 3 phases and vice versa, 0 to 1200 s.
UInt16s1R
12802
Current L1
0x0500-0x0501. RMS output current of phase L1.
Float32A1R
12822
Current L2
0x0502-0x0503. RMS output current of phase L2.
Float32A1R
12842
Current L3
0x0504-0x0505. RMS output current of phase L3.
Float32A1R
12862
Voltage L1
0x0506-0x0507. RMS output voltage of phase L1.
Float32V1R
12882
Voltage L2
0x0508-0x0509. RMS output voltage of phase L2.
Float32V1R
12902
Voltage L3
0x050A-0x050B. RMS output voltage of phase L3.
Float32V1R
12922
Power L1
0x050C-0x050D. Actual power on phase L1.
Float32W1R
12942
Power L2
0x050E-0x050F. Actual power on phase L2.
Float32W1R
12962
Power L3
0x0510-0x0511. Actual power on phase L3.
Float32W1R
12982
Power overall
0x0512-0x0513. Actual overall power on all phases.
Float32W1R
23042
Temperature
0x0900-0x0901. Temperature inside the EVSE.
Float32°C1R
28162
Max current, session
0x0B00-0x0B01. Maximum charging current of the session, evaluated from every static restriction (installation current, cable, ...).
Float32A1R
28182
Charged energy, session
0x0B02-0x0B03. Energy transferred within the current charging session.
Float32kWh1R
28202
Duration, session
0x0B04-0x0B05. Duration of the current charging session in seconds.
UInt32s1R
28221
Detected EV phases
0x0B06. 0 = not initialised, 1 = 1 phase, 2 = 2 phases, 3 = 3 phases detected.
UInt16-1R
33281
Heartbeat, energy manager
0x0D00. Write 0x55AA (21930) at least every 10 s. Without the heartbeat the station turns into the error state when no fallback current (0x030E) is configured.
UInt16-1W
33301
Cable lock status
0x0D02. 0 = unknown, 1 = cable unlocked, 2 = cable locked, 3 = fixed cable.
UInt16-1R
33311
Solar charging mode
0x0D03. 0 = solar mode not active, 1 = fast charging (standard), 2 = solar charging (Sunshine), 3 = solar-supported charging (Sunshine+). Triggers the HMI only: the algorithm stays with the energy manager, and solar mode also has to be enabled with DIP 7.
UInt16-1RW
33321
Requested phases
0x0D04. 0 = regular charging on all available phases, 1 = force charging on one phase only. Ignored when the hardware does not support phase switching (0x030C). The station performs the switch itself following CharIN, including the pause from 0x0314.
UInt16-1RW
33331
Charging release, energy manager
0x0D05. 0 = charging not allowed (relays open), 1 = charging allowed (relays closed).
UInt16-1RW
33341
Lock EVSE
0x0D06. 0 = not locked, 1 = locked (charging prevented).
UInt16-1RW
33531
System restart
0x0D19. Send 0xBB once to restart the system; only in the idle state.
UInt16-1W
35841
Active error code
0x0E00. 0 = no error, 200 = energy manager not available (no heartbeat), 2011 = EV overcurrent, 2300-2305 = over-/undervoltage on L1/L2/L3, 2323 = connected-phases mismatch (the last three only with voltage detection active).
UInt16-1R
35851
Master lost fallback state
0x0E01. 0 = not active, 1 = active (energy manager currently unavailable).
UInt16-1R
35861
Switched phases
0x0E02. 0 = regular charging on all available phases, 1 = single-phase charging.
UInt16-1R
40962
Charged energy, total
0x1000-0x1001. Cumulative energy on the AC port over all time; not usable for billing.
Float32kWh1R
40982
Charging sessions, total
0x1002-0x1003. Total number of charging sessions.
UInt32-1R

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

Source: MENNEKES, "AMTRON 4You 300 / AMTRON Compact 2.0s / AMTRON Start 2.0s - Modbus RTU Specification", doc. revision 2.5, 2025-07-11 (register settings v01.03, from software 2023.21.11024), vendor PDF at https://www.mennekes.de/fileadmin/MEN-Deutschland/emobility/01_documents/04_installer/Modbus_RTU_Specification_AMTRON_4You300_Compact_2.0s_Start_2.0s-v2.5.pdf, linked from the MENNEKES Modbus RTU page given as supplier_url. Section 1 fixes the factory RS-485 settings recorded here (57600 bit/s, 8 data bits, no parity, 2 stop bits, big endian) with default Modbus address 50, settable only between 10 and 50, in the satellite mode enabled by DIP 4 and 5 on bank S1. Reads are FC3 or FC4, writes FC6/FC16; the appendix lists hex addresses starting at 0x0000, so the addresses below are the vendor's hex values as decimals with zero_based framing, and the worked EMS sequence (0x0D00 = 0x55AA heartbeat, 0x0D05 release, 0x0302 current limit) confirms that numbering. Rows sit in holding registers because the station answers both FC3 and FC4 with the same data and the writable ones must be holding registers. The three models in the title share this one map (evcc's 'mennekes-compact' also covers the Kostal Enector, the same hardware). The AMTRON HCC3 family is a different map and stays in mennekes-amtron-hcc3; AMTRON Professional/AMEDIO run a Bender CC612/CC613 and stay in bender-cc612-cc613. Caveats from the document: a master heartbeat is needed at least every 10 s, the release must be 1 and the energy-manager limit at least 6 A; 0x0302 = 0 means no limitation (the station signals its maximum), 0.01 to 5.99 A are treated as 0 A, and after a reboot or a lost energy manager the station only returns to idle after 0x0D00, 0x0D05 and 0x0302 are written. Dynamic phase switching needs an 11 kW unit (0x030C = 2). Every row of the appendix table is included.