FoxESS · Solar inverter

H3-Pro / H3 Smart hybrid inverter (also A-Tronix AX Plus) Modbus register map

Default configuration

Protocol
Modbus TCP
Port
502
Unit ID
247
Addressing
0-based
Byte order
Big endian
Word order
High word first

Register map

AddressCountNameTypeUnitScaleAccess
376121
Battery state of charge
Int16%1R
388162
Meter power, phase R
The cited template negates and scales it by 0.1, so a positive register value means export.
Int32W-0.1R
388182
Meter power, phase S
Int32W-0.1R
388202
Meter power, phase T
Int32W-0.1R
392372
Battery charge/discharge power
Int32W1R
392792
PV1 power
Int32W1R
392812
PV2 power
Int32W1R
392832
PV3 power
Int32W1R
392852
PV4 power
Int32W1R
392872
PV5 power
Int32W1R
392892
PV6 power
Int32W1R
396172
Grid consumption total
UInt32kWh0.01R
460011
Remote control
The cited template writes 0 (disabled) and 1 (enabled).
UInt16-1RW
460021
Remote control timeout
The cited template writes 60.
UInt16s1RW
460032
Remote active power setpoint
The template writes a negative value to force charging; the word layout is high word at 46003 and low word at 46004.
Int32W1RW
466081
Battery maximum discharge current
The template writes the configured current multiplied by 10. Its help text says the inverter factory default is 50 A on H3-Pro/Smart (26 A on the older H3), and that 0 blocks discharge completely.
UInt16A0.1RW
466091
Minimum state of charge
UInt16%1RW
466101
Maximum state of charge
UInt16%1RW
466111
Minimum state of charge, on-grid reserve
Discharge floor that must stay below the maximum state of charge; the inverter rejects a maximum SOC at or below this value.
UInt16%1RW
492031
Work mode
The cited template writes 1 for self use and 3 for back-up.
UInt16-1RW

Read this device live with Modbus Connect, free for Windows, macOS and Linux

Related guides

Notes

Source: the evcc meter template https://raw.githubusercontent.com/evcc-io/evcc/master/templates/definition/meter/fox-ess-h3-smart.yaml, used as a secondary source; no FoxESS register document was retrieved. It covers the FoxESS H3-Pro / H3 Smart series hybrid inverter and the A-Tronix AX Plus. This is NOT the same map as the older H3 generation in the fox-ess-h3 seed: that one lives in the 31xxx/41xxx/44xxx blocks, while this generation reports PV, battery and meter data in the 37xxx/38xxx/39xxx blocks and is controlled through 46xxx/49xxx. Do not use the two interchangeably. The template offers RS-485 and TCP access with unit ID 247; this seed records the TCP path (port 502, unit ID 247) because the template states no RS-485 baud rate or framing. All rows are holding registers; the PV rows are read as one 12-register block (39279-39290). Scales, types and the write values above are the template's own encoding. The template needs the battery's maximum discharge current as a parameter (it writes it back when leaving hold mode), which is why the 0.1 A scaling of 46608 is recorded here.