  "spec_version": 1,
  "slug": "regin-corrigo-e-ventilation",
  "manufacturer": "Regin",
  "model": "Corrigo E Ventilation (all versions from 3.2)",
  "category": "HVAC controller",
  "supplier_url": "https://www.regincontrols.com/",
  "default_configuration": {
    "protocol": "modbus_tcp",
    "port": 502,
    "unit_id": 1,
    "addressing": "zero_based",
    "byte_order": "BigEndian",
    "word_order": "HighFirst",
    "native_interface": "rs485",
    "serial": {
      "parity": "None",
      "baud_rate": 9600,
      "data_bits": 8,
      "stop_bits": 1
    }
  },
  "coils": [
    {
      "address": 1,
      "count": 1,
      "name": "Enable fast stop if overheat alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_OverHeatFastStop, EXOL type L, Modbus address 1, default value 0. Settings, General."
    },
    {
      "address": 2,
      "count": 1,
      "name": "Block cooling step signals if set and alarm \"Run Error P1-Cooler\"",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepAlarmBlock, EXOL type L, Modbus address 2, default value 0. Settings, General."
    },
    {
      "address": 3,
      "count": 1,
      "name": "Command to acknowledge all alarms",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_AlaAcknowAll, EXOL type L, Modbus address 3, default value 0. Settings, General."
    },
    {
      "address": 5,
      "count": 1,
      "name": "Enable the night cool function when Recirculation run",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleNightCool, EXOL type L, Modbus address 5, default value 0. Recirculation."
    },
    {
      "address": 6,
      "count": 1,
      "name": "Use ExtraTimeGroup 5 to start Recirculation run",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleExtraTimeGroup5, EXOL type L, Modbus address 6, default value 0. Recirculation."
    },
    {
      "address": 7,
      "count": 1,
      "name": "Set only if SAF pressure should be compensated",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings. Cor_CompSAFOnly, EXOL type L, Modbus address 7, default value 0. SAF/EAF Pressure and Flow."
    },
    {
      "address": 8,
      "count": 1,
      "name": "Enable support control if the unit is shut down",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NeedControl, EXOL type L, Modbus address 8, default value 0. Settings, General."
    },
    {
      "address": 9,
      "count": 1,
      "name": "Enable the de-icing function",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DeIcingFunction, EXOL type L, Modbus address 9, default value 0. Extract air temp/De-icing exchanger."
    },
    {
      "address": 10,
      "count": 1,
      "name": "Resets the filter alarm counter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FilterAlarmReset, EXOL type L, Modbus address 10, default value 0. Settings, General."
    }
  ],
  "discrete_inputs": [
    {
      "address": 1,
      "count": 1,
      "name": "Set if timechannel full speed is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupFanFullSpeed, EXOL type L, Modbus address 1. Actual/Setpoint."
    },
    {
      "address": 2,
      "count": 1,
      "name": "Set if timechannel reduced speed is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupFanHalfSpeed, EXOL type L, Modbus address 2. Actual/Setpoint."
    },
    {
      "address": 3,
      "count": 1,
      "name": "Set if timer output 1 is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupCor_ExtraTimeG roup1, EXOL type L, Modbus address 3. Actual/Setpoint."
    },
    {
      "address": 4,
      "count": 1,
      "name": "Set if timer output 2 is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupCor_ExtraTimeG roup2, EXOL type L, Modbus address 4. Actual/Setpoint."
    },
    {
      "address": 5,
      "count": 1,
      "name": "Set if timer output 3 is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupCor_ExtraTimeG roup3, EXOL type L, Modbus address 5. Actual/Setpoint."
    },
    {
      "address": 6,
      "count": 1,
      "name": "Set if timer output 4 is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupCor_ExtraTimeG roup4, EXOL type L, Modbus address 6. Actual/Setpoint."
    },
    {
      "address": 7,
      "count": 1,
      "name": "Set if timer output 5 is active",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal TimePro.TimeGroupCor_ExtraTimeG roup5, EXOL type L, Modbus address 7. Actual/Setpoint."
    },
    {
      "address": 8,
      "count": 1,
      "name": "Set if extended operation full speed",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtendedRunActive Full, EXOL type L, Modbus address 8. Actual/Setpoint."
    },
    {
      "address": 9,
      "count": 1,
      "name": "Set if extended operation half speed",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtendedRunActive Half, EXOL type L, Modbus address 9. Actual/Setpoint."
    },
    {
      "address": 10,
      "count": 1,
      "name": "Set if ongoing support heating",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_NeedHeatActive, EXOL type L, Modbus address 10. Supply, Extract and Room temperatures."
    },
    {
      "address": 11,
      "count": 1,
      "name": "Set if ongoing support cooling",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual. Cor_NeedCoolActive, EXOL type L, Modbus address 11. Supply, Extract and Room temperatures."
    },
    {
      "address": 12,
      "count": 1,
      "name": "Set if ongoing support CO 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_DemandCO2Active, EXOL type L, Modbus address 12. CO 2."
    },
    {
      "address": 13,
      "count": 1,
      "name": "Set if ongoing de-icing",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_DeIcingActive, EXOL type L, Modbus address 13. Extract air temp/De-icing exchanger."
    },
    {
      "address": 14,
      "count": 1,
      "name": "Value of DI1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI1, EXOL type L, Modbus address 14. Digital inputs."
    },
    {
      "address": 15,
      "count": 1,
      "name": "Value of DI2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI2, EXOL type L, Modbus address 15. Digital inputs."
    },
    {
      "address": 16,
      "count": 1,
      "name": "Value of DI3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI3, EXOL type L, Modbus address 16. Digital inputs."
    },
    {
      "address": 17,
      "count": 1,
      "name": "Value of DI4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI4, EXOL type L, Modbus address 17. Digital inputs."
    },
    {
      "address": 18,
      "count": 1,
      "name": "Value of DI5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI5, EXOL type L, Modbus address 18. Digital inputs."
    },
    {
      "address": 19,
      "count": 1,
      "name": "Value of DI6",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI6, EXOL type L, Modbus address 19. Digital inputs."
    },
    {
      "address": 20,
      "count": 1,
      "name": "Value of DI7",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI7, EXOL type L, Modbus address 20. Digital inputs."
    },
    {
      "address": 21,
      "count": 1,
      "name": "Value of DI8",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI8, EXOL type L, Modbus address 21. Digital inputs."
    },
    {
      "address": 22,
      "count": 1,
      "name": "Value of UDI1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI9, EXOL type L, Modbus address 22. Universal inputs."
    },
    {
      "address": 23,
      "count": 1,
      "name": "Value of UDI2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI10, EXOL type L, Modbus address 23. Universal inputs."
    },
    {
      "address": 24,
      "count": 1,
      "name": "Value of UDI3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI11, EXOL type L, Modbus address 24. Universal inputs."
    },
    {
      "address": 25,
      "count": 1,
      "name": "Value of UDI4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.DI12, EXOL type L, Modbus address 25. Universal inputs."
    },
    {
      "address": 26,
      "count": 1,
      "name": "Value of DO1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq1, EXOL type L, Modbus address 26. Digital outputs."
    },
    {
      "address": 27,
      "count": 1,
      "name": "Value of DO2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq2, EXOL type L, Modbus address 27. Digital outputs."
    },
    {
      "address": 28,
      "count": 1,
      "name": "Value of DO3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq3, EXOL type L, Modbus address 28. Digital outputs."
    },
    {
      "address": 29,
      "count": 1,
      "name": "Value of DO4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq4, EXOL type L, Modbus address 29. Digital outputs."
    },
    {
      "address": 30,
      "count": 1,
      "name": "Value of DO5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq5, EXOL type L, Modbus address 30. Digital outputs."
    },
    {
      "address": 31,
      "count": 1,
      "name": "Value of DO6",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq6, EXOL type L, Modbus address 31. Digital outputs."
    },
    {
      "address": 32,
      "count": 1,
      "name": "Value of DO7",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QDig.Dq7, EXOL type L, Modbus address 32. Digital outputs."
    },
    {
      "address": 33,
      "count": 1,
      "name": "Run Error Supply Air Fan 0=No alarm 1=Alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(1), EXOL type L, Modbus address 33. Alarm Points."
    },
    {
      "address": 34,
      "count": 1,
      "name": "Run Error Extract Air Fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(2), EXOL type L, Modbus address 34. Alarm Points."
    },
    {
      "address": 35,
      "count": 1,
      "name": "Run Error P1-Heater",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(3), EXOL type L, Modbus address 35. Alarm Points."
    },
    {
      "address": 36,
      "count": 1,
      "name": "Run Error P1-Cooler",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(4), EXOL type L, Modbus address 36. Alarm Points."
    },
    {
      "address": 37,
      "count": 1,
      "name": "Run Error P1-Exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(5), EXOL type L, Modbus address 37. Alarm Points."
    },
    {
      "address": 38,
      "count": 1,
      "name": "Filter guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(6), EXOL type L, Modbus address 38. Alarm Points."
    },
    {
      "address": 39,
      "count": 1,
      "name": "Flow guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(7), EXOL type L, Modbus address 39. Alarm Points."
    },
    {
      "address": 40,
      "count": 1,
      "name": "External frost guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(8), EXOL type L, Modbus address 40. Alarm Points."
    },
    {
      "address": 41,
      "count": 1,
      "name": "Deicing pressure guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(9), EXOL type L, Modbus address 41. Alarm Points."
    },
    {
      "address": 42,
      "count": 1,
      "name": "Fire alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(10), EXOL type L, Modbus address 42. Alarm Points."
    },
    {
      "address": 43,
      "count": 1,
      "name": "External switch",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(11), EXOL type L, Modbus address 43. Alarm Points."
    },
    {
      "address": 44,
      "count": 1,
      "name": "External alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(12), EXOL type L, Modbus address 44. Alarm Points."
    },
    {
      "address": 45,
      "count": 1,
      "name": "Supply Air control error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(13), EXOL type L, Modbus address 45. Alarm Points."
    },
    {
      "address": 46,
      "count": 1,
      "name": "Deviation Humidity control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(14), EXOL type L, Modbus address 46. Alarm Points."
    },
    {
      "address": 47,
      "count": 1,
      "name": "High supply air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(15), EXOL type L, Modbus address 47. Alarm Points."
    },
    {
      "address": 48,
      "count": 1,
      "name": "Low supply air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(16), EXOL type L, Modbus address 48. Alarm Points."
    },
    {
      "address": 49,
      "count": 1,
      "name": "Supply Air Fan max limit",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(17), EXOL type L, Modbus address 49. Alarm Points."
    },
    {
      "address": 50,
      "count": 1,
      "name": "Supply Air Fan min limit",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(18), EXOL type L, Modbus address 50. Alarm Points."
    },
    {
      "address": 51,
      "count": 1,
      "name": "High room temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(19), EXOL type L, Modbus address 51. Alarm Points."
    },
    {
      "address": 52,
      "count": 1,
      "name": "Low room temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(20), EXOL type L, Modbus address 52. Alarm Points."
    },
    {
      "address": 53,
      "count": 1,
      "name": "High extract air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(21), EXOL type L, Modbus address 53. Alarm Points."
    },
    {
      "address": 54,
      "count": 1,
      "name": "Low extract air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(22), EXOL type L, Modbus address 54. Alarm Points."
    },
    {
      "address": 55,
      "count": 1,
      "name": "Electric heating is overheated",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(23), EXOL type L, Modbus address 55. Alarm Points."
    },
    {
      "address": 56,
      "count": 1,
      "name": "Frost risk",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(24), EXOL type L, Modbus address 56. Alarm Points."
    },
    {
      "address": 57,
      "count": 1,
      "name": "Low frost guard temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(25), EXOL type L, Modbus address 57. Alarm Points."
    },
    {
      "address": 58,
      "count": 1,
      "name": "Low efficiency",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(26), EXOL type L, Modbus address 58. Alarm Points."
    },
    {
      "address": 59,
      "count": 1,
      "name": "Sensor error outdoor temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(27), EXOL type L, Modbus address 59. Alarm Points."
    },
    {
      "address": 60,
      "count": 1,
      "name": "Analogue deicing",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(28), EXOL type L, Modbus address 60. Alarm Points."
    },
    {
      "address": 61,
      "count": 1,
      "name": "Rotation guard exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(29), EXOL type L, Modbus address 61. Alarm Points."
    },
    {
      "address": 62,
      "count": 1,
      "name": "Fire damper is out of operation",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(30), EXOL type L, Modbus address 62. Alarm Points."
    },
    {
      "address": 63,
      "count": 1,
      "name": "Supply Air Fan control error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(31), EXOL type L, Modbus address 63. Alarm Points."
    },
    {
      "address": 64,
      "count": 1,
      "name": "Extract Air Fan control error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(32), EXOL type L, Modbus address 64. Alarm Points."
    },
    {
      "address": 65,
      "count": 1,
      "name": "Supply Air Fan external operation",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(33), EXOL type L, Modbus address 65. Alarm Points."
    },
    {
      "address": 66,
      "count": 1,
      "name": "Extract Air Fan external operation",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(34), EXOL type L, Modbus address 66. Alarm Points."
    },
    {
      "address": 67,
      "count": 1,
      "name": "Ventilation Manual mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(35), EXOL type L, Modbus address 67. Alarm Points."
    },
    {
      "address": 68,
      "count": 1,
      "name": "Manual supply air control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(36), EXOL type L, Modbus address 68. Alarm Points."
    },
    {
      "address": 69,
      "count": 1,
      "name": "Manual Supply Air Fan mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(37), EXOL type L, Modbus address 69. Alarm Points."
    },
    {
      "address": 70,
      "count": 1,
      "name": "Manual Supply Air Fan freq control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(38), EXOL type L, Modbus address 70. Alarm Points."
    },
    {
      "address": 71,
      "count": 1,
      "name": "Manual Extract Air Fan mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(39), EXOL type L, Modbus address 71. Alarm Points."
    },
    {
      "address": 72,
      "count": 1,
      "name": "Manual Extract Air Fan freq control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(40), EXOL type L, Modbus address 72. Alarm Points."
    },
    {
      "address": 73,
      "count": 1,
      "name": "Manual heater control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(41), EXOL type L, Modbus address 73. Alarm Points."
    },
    {
      "address": 74,
      "count": 1,
      "name": "Manual cooler control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(42), EXOL type L, Modbus address 74. Alarm Points."
    },
    {
      "address": 75,
      "count": 1,
      "name": "Manual exchanger control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(43), EXOL type L, Modbus address 75. Alarm Points."
    },
    {
      "address": 76,
      "count": 1,
      "name": "Manual P1-Heater",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(44), EXOL type L, Modbus address 76. Alarm Points."
    },
    {
      "address": 77,
      "count": 1,
      "name": "Manual P1-Cooler",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(45), EXOL type L, Modbus address 77. Alarm Points."
    },
    {
      "address": 78,
      "count": 1,
      "name": "Manual P1-Exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(46), EXOL type L, Modbus address 78. Alarm Points."
    },
    {
      "address": 79,
      "count": 1,
      "name": "Manual fire damper",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(47), EXOL type L, Modbus address 79. Alarm Points."
    },
    {
      "address": 80,
      "count": 1,
      "name": "Internal battery error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(48), EXOL type L, Modbus address 80. Alarm Points."
    },
    {
      "address": 81,
      "count": 1,
      "name": "Start signal full speed supply air fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFStart1(0), EXOL type L, Modbus address 81. SAF/EAF Pressure and Flow."
    },
    {
      "address": 82,
      "count": 1,
      "name": "Start signal full speed extract air fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFStart1, EXOL type L, Modbus address 82. SAF/EAF Pressure and Flow."
    },
    {
      "address": 83,
      "count": 1,
      "name": "Start signal half speed supply air fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFStart2, EXOL type L, Modbus address 83. SAF/EAF Pressure and Flow."
    },
    {
      "address": 84,
      "count": 1,
      "name": "Start signal half speed extract air fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFStart2, EXOL type L, Modbus address 84. SAF/EAF Pressure and Flow."
    },
    {
      "address": 85,
      "count": 1,
      "name": "Start signal Heat Pump",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HeatPumpStart(0), EXOL type L, Modbus address 85. Actual/Setpoint."
    },
    {
      "address": 86,
      "count": 1,
      "name": "Start signal Exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExchPumpStart, EXOL type L, Modbus address 86. Actual/Setpoint."
    },
    {
      "address": 87,
      "count": 1,
      "name": "Start signal Cool Pump",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_CoolPumpStart, EXOL type L, Modbus address 87. Actual/Setpoint."
    },
    {
      "address": 88,
      "count": 1,
      "name": "Start signal frequencer supply air fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFFrequencyStart, EXOL type L, Modbus address 88. SAF/EAF Pressure and Flow."
    },
    {
      "address": 89,
      "count": 1,
      "name": "Start signal frequencer extract air fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFFrequencyStart, EXOL type L, Modbus address 89. SAF/EAF Pressure and Flow."
    },
    {
      "address": 90,
      "count": 1,
      "name": "Sensor error Supply Air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(49), EXOL type L, Modbus address 90. Alarm Points."
    },
    {
      "address": 91,
      "count": 1,
      "name": "Sensor error Extract Air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(50), EXOL type L, Modbus address 91. Alarm Points."
    },
    {
      "address": 92,
      "count": 1,
      "name": "Sensor error Room temp 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(51), EXOL type L, Modbus address 92. Alarm Points."
    },
    {
      "address": 93,
      "count": 1,
      "name": "Sensor error Room temp 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(52), EXOL type L, Modbus address 93. Alarm Points."
    },
    {
      "address": 94,
      "count": 1,
      "name": "Sensor error Extract Air temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(53), EXOL type L, Modbus address 94. Alarm Points."
    },
    {
      "address": 95,
      "count": 1,
      "name": "Sensor error Extra sensor",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(54), EXOL type L, Modbus address 95. Alarm Points."
    },
    {
      "address": 96,
      "count": 1,
      "name": "Sensor error SAF pressure",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(55), EXOL type L, Modbus address 96. Alarm Points."
    },
    {
      "address": 97,
      "count": 1,
      "name": "Sensor error EAF pressure",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(56), EXOL type L, Modbus address 97. Alarm Points."
    },
    {
      "address": 98,
      "count": 1,
      "name": "Sensor error Deicing temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(57), EXOL type L, Modbus address 98. Alarm Points."
    },
    {
      "address": 99,
      "count": 1,
      "name": "Sensor error Frost Protection temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(58), EXOL type L, Modbus address 99. Alarm Points."
    },
    {
      "address": 100,
      "count": 1,
      "name": "Sensor error CO 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(59), EXOL type L, Modbus address 100. Alarm Points."
    },
    {
      "address": 101,
      "count": 1,
      "name": "Sensor error Humidity room",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(60), EXOL type L, Modbus address 101. Alarm Points."
    },
    {
      "address": 102,
      "count": 1,
      "name": "Sensor error Humidity duct",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(61), EXOL type L, Modbus address 102. Alarm Points."
    },
    {
      "address": 103,
      "count": 1,
      "name": "Sensor error Extra unit temp",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(62), EXOL type L, Modbus address 103. Alarm Points."
    },
    {
      "address": 104,
      "count": 1,
      "name": "Sensor error External control SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(63), EXOL type L, Modbus address 104. Alarm Points."
    },
    {
      "address": 105,
      "count": 1,
      "name": "Sensor error External control EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(64), EXOL type L, Modbus address 105. Alarm Points."
    },
    {
      "address": 106,
      "count": 1,
      "name": "Sensor error SAF Pressure 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(65), EXOL type L, Modbus address 106. Alarm Points."
    },
    {
      "address": 107,
      "count": 1,
      "name": "Sensor error Humidity Outdoor",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(66), EXOL type L, Modbus address 107. Alarm Points."
    },
    {
      "address": 108,
      "count": 1,
      "name": "Sensor error Reserved 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(67), EXOL type L, Modbus address 108. Alarm Points."
    },
    {
      "address": 109,
      "count": 1,
      "name": "Sensor error Reserved 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(68), EXOL type L, Modbus address 109. Alarm Points."
    },
    {
      "address": 110,
      "count": 1,
      "name": "Sensor error Reserved 3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(69), EXOL type L, Modbus address 110. Alarm Points."
    },
    {
      "address": 111,
      "count": 1,
      "name": "Sensor error Reserved 4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(70), EXOL type L, Modbus address 111. Alarm Points."
    },
    {
      "address": 112,
      "count": 1,
      "name": "Sensor error Reserved 5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(71), EXOL type L, Modbus address 112. Alarm Points."
    },
    {
      "address": 113,
      "count": 1,
      "name": "Sensor error Reserved 6",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(72), EXOL type L, Modbus address 113. Alarm Points."
    },
    {
      "address": 114,
      "count": 1,
      "name": "Sensor error Reserved 7",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(73), EXOL type L, Modbus address 114. Alarm Points."
    },
    {
      "address": 115,
      "count": 1,
      "name": "Sensor error Reserved 8",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(74), EXOL type L, Modbus address 115. Alarm Points."
    },
    {
      "address": 116,
      "count": 1,
      "name": "Sensor error Reserved 9",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(75), EXOL type L, Modbus address 116. Alarm Points."
    },
    {
      "address": 117,
      "count": 1,
      "name": "Sensor error Reserved 10",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(76), EXOL type L, Modbus address 117. Alarm Points."
    },
    {
      "address": 118,
      "count": 1,
      "name": "Alarm Frequency Converter SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(77), EXOL type L, Modbus address 118. Alarm Points."
    },
    {
      "address": 119,
      "count": 1,
      "name": "Alarm Frequency Converter EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(78), EXOL type L, Modbus address 119. Alarm Points."
    },
    {
      "address": 120,
      "count": 1,
      "name": "Communication error Frequency SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(79), EXOL type L, Modbus address 120. Alarm Points."
    },
    {
      "address": 121,
      "count": 1,
      "name": "Communication error Frequency EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(80), EXOL type L, Modbus address 121. Alarm Points."
    },
    {
      "address": 122,
      "count": 1,
      "name": "Communication error Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(81), EXOL type L, Modbus address 122. Alarm Points."
    },
    {
      "address": 123,
      "count": 1,
      "name": "Communication error Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(82), EXOL type L, Modbus address 123. Alarm Points."
    },
    {
      "address": 124,
      "count": 1,
      "name": "Warning Frequency Converter SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(83), EXOL type L, Modbus address 124. Alarm Points."
    },
    {
      "address": 125,
      "count": 1,
      "name": "Warning Frequency Converter EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(84), EXOL type L, Modbus address 125. Alarm Points."
    },
    {
      "address": 126,
      "count": 1,
      "name": "Output in manual mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(85), EXOL type L, Modbus address 126. Alarm Points."
    },
    {
      "address": 127,
      "count": 1,
      "name": "Time for service",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(86), EXOL type L, Modbus address 127. Alarm Points."
    },
    {
      "address": 128,
      "count": 1,
      "name": "Manual Y4-Extra Sequence control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(87), EXOL type L, Modbus address 128. Alarm Points."
    },
    {
      "address": 129,
      "count": 1,
      "name": "Restart blocked after power-on",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(88), EXOL type L, Modbus address 129. Alarm Points."
    },
    {
      "address": 130,
      "count": 1,
      "name": "Manual Y5-Extra Sequence control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AlaPt(89), EXOL type L, Modbus address 130. Alarm Points."
    },
    {
      "address": 145,
      "count": 1,
      "name": "Value of DI1 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn1, EXOL type L, Modbus address 145. Digital inputs."
    },
    {
      "address": 146,
      "count": 1,
      "name": "Value of DI2 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn2, EXOL type L, Modbus address 146. Digital inputs."
    },
    {
      "address": 147,
      "count": 1,
      "name": "Value of DI3 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn3, EXOL type L, Modbus address 147. Digital inputs."
    },
    {
      "address": 148,
      "count": 1,
      "name": "Value of DI4 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn4, EXOL type L, Modbus address 148. Digital inputs."
    },
    {
      "address": 149,
      "count": 1,
      "name": "Value of DI5 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn5, EXOL type L, Modbus address 149. Digital inputs."
    },
    {
      "address": 150,
      "count": 1,
      "name": "Value of DI6 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn6, EXOL type L, Modbus address 150. Digital inputs."
    },
    {
      "address": 151,
      "count": 1,
      "name": "Value of DI7 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn7, EXOL type L, Modbus address 151. Digital inputs."
    },
    {
      "address": 152,
      "count": 1,
      "name": "Value of DI8 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn8, EXOL type L, Modbus address 152. Digital inputs."
    },
    {
      "address": 153,
      "count": 1,
      "name": "Value of UDI1 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn9, EXOL type L, Modbus address 153. Universal inputs."
    },
    {
      "address": 154,
      "count": 1,
      "name": "Value of UDI2 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn10, EXOL type L, Modbus address 154. Universal inputs."
    },
    {
      "address": 155,
      "count": 1,
      "name": "Value of UD3 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn11, EXOL type L, Modbus address 155. Universal inputs."
    },
    {
      "address": 156,
      "count": 1,
      "name": "Value of UD4 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigIn12, EXOL type L, Modbus address 156. Universal inputs."
    },
    {
      "address": 157,
      "count": 1,
      "name": "Value of DO1 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut1, EXOL type L, Modbus address 157. Digital outputs."
    },
    {
      "address": 158,
      "count": 1,
      "name": "Value of DO2 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut2, EXOL type L, Modbus address 158. Digital outputs."
    },
    {
      "address": 159,
      "count": 1,
      "name": "Value of DO3 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut3, EXOL type L, Modbus address 159. Digital outputs."
    },
    {
      "address": 160,
      "count": 1,
      "name": "Value of DO4 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut4, EXOL type L, Modbus address 160. Digital outputs."
    },
    {
      "address": 161,
      "count": 1,
      "name": "Value of DO5 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut5, EXOL type L, Modbus address 161. Digital outputs."
    },
    {
      "address": 162,
      "count": 1,
      "name": "Value of DO6 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut6, EXOL type L, Modbus address 162. Digital outputs."
    },
    {
      "address": 163,
      "count": 1,
      "name": "Value of DO7 Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1DigOut7, EXOL type L, Modbus address 163. Digital outputs."
    },
    {
      "address": 164,
      "count": 1,
      "name": "Value of DI1 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn1, EXOL type L, Modbus address 164. Digital inputs."
    },
    {
      "address": 165,
      "count": 1,
      "name": "Value of DI2 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn2, EXOL type L, Modbus address 165. Digital inputs."
    },
    {
      "address": 166,
      "count": 1,
      "name": "Value of DI3 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn3, EXOL type L, Modbus address 166. Digital inputs."
    },
    {
      "address": 167,
      "count": 1,
      "name": "Value of DI4 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn4, EXOL type L, Modbus address 167. Digital inputs."
    },
    {
      "address": 168,
      "count": 1,
      "name": "Value of DI5 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn5, EXOL type L, Modbus address 168. Digital inputs."
    },
    {
      "address": 169,
      "count": 1,
      "name": "Value of DI6 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn6, EXOL type L, Modbus address 169. Digital inputs."
    },
    {
      "address": 170,
      "count": 1,
      "name": "Value of DI7 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn7, EXOL type L, Modbus address 170. Digital inputs."
    },
    {
      "address": 171,
      "count": 1,
      "name": "Value of DI8 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn8, EXOL type L, Modbus address 171. Digital inputs."
    },
    {
      "address": 172,
      "count": 1,
      "name": "Value of UDI1 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn9, EXOL type L, Modbus address 172. Universal inputs."
    },
    {
      "address": 173,
      "count": 1,
      "name": "Value of UDI2 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn10, EXOL type L, Modbus address 173. Universal inputs."
    },
    {
      "address": 174,
      "count": 1,
      "name": "Value of UDI3 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn11, EXOL type L, Modbus address 174. Universal inputs."
    },
    {
      "address": 175,
      "count": 1,
      "name": "Value of UDI4 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigIn12, EXOL type L, Modbus address 175. Universal inputs."
    },
    {
      "address": 176,
      "count": 1,
      "name": "Value of DO1 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut1, EXOL type L, Modbus address 176. Digital outputs."
    },
    {
      "address": 177,
      "count": 1,
      "name": "Value of DO2 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut2, EXOL type L, Modbus address 177. Digital outputs."
    },
    {
      "address": 178,
      "count": 1,
      "name": "Value of DO3 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut3, EXOL type L, Modbus address 178. Digital outputs."
    },
    {
      "address": 179,
      "count": 1,
      "name": "Value of DO4 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut4, EXOL type L, Modbus address 179. Digital outputs."
    },
    {
      "address": 180,
      "count": 1,
      "name": "Value of DO5 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut5, EXOL type L, Modbus address 180. Digital outputs."
    },
    {
      "address": 181,
      "count": 1,
      "name": "Value of DO6 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut6, EXOL type L, Modbus address 181. Digital outputs."
    },
    {
      "address": 182,
      "count": 1,
      "name": "Value of DO7 Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2DigOut7, EXOL type L, Modbus address 182. Digital outputs."
    },
    {
      "address": 183,
      "count": 1,
      "name": "Start signal Heat Pump",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_RecycleRunActive, EXOL type L, Modbus address 183. Actual/Setpoint."
    },
    {
      "address": 184,
      "count": 1,
      "name": "Sum alarm: Set if any A or B alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SumAlarm, EXOL type L, Modbus address 184. Alarm Status."
    },
    {
      "address": 185,
      "count": 1,
      "name": "A-alarm: Set if any A-alarm in controller",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SumAlarmA, EXOL type L, Modbus address 185. Alarm Status."
    },
    {
      "address": 186,
      "count": 1,
      "name": "B-alarm: Set if any B-alarm in controller",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SumAlarmB, EXOL type L, Modbus address 186. Alarm Status."
    }
  ],
  "input_registers": [
    {
      "address": 1,
      "count": 1,
      "name": "Outdoor temperature (read-only)",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_Outdoor temp(0), EXOL type R, Modbus address 1. Actual/Setpoint."
    },
    {
      "address": 2,
      "count": 1,
      "name": "Efficiency in % for exchanger",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_Efficiency, EXOL type R, Modbus address 2. Actual/Setpoint."
    },
    {
      "address": 3,
      "count": 1,
      "name": "0=Stopped 1=Starting up 2=Starting reduced speed 3=Starting full speed 4=Starting normal run 5=Normal run 6=Support control heating 7=Support control cooling 8=CO run 2 9=Night cooling 10...",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_RunMode, EXOL type X, Modbus address 3. Actual/Setpoint."
    },
    {
      "address": 6,
      "count": 1,
      "name": "Number of minutes extended operation",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtendedRunMin, EXOL type I, Modbus address 6. Actual/Setpoint."
    },
    {
      "address": 7,
      "count": 1,
      "name": "Supply air temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SupplyAirTemp, EXOL type R, Modbus address 7. Supply, Extract and Room temperatures."
    },
    {
      "address": 8,
      "count": 1,
      "name": "Calculated setpoint supply air temperature when outdoor compensated control function",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SupplyPID_SetP, EXOL type R, Modbus address 8. Supply, Extract and Room temperatures."
    },
    {
      "address": 9,
      "count": 1,
      "name": "Extract air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtractAirTemp, EXOL type R, Modbus address 9. Supply, Extract and Room temperatures."
    },
    {
      "address": 10,
      "count": 1,
      "name": "Room temperature 1",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_RoomTemp1, EXOL type R, Modbus address 10. Supply, Extract and Room temperatures."
    },
    {
      "address": 11,
      "count": 1,
      "name": "Room temperature 2",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_RoomTemp2, EXOL type R, Modbus address 11. Supply, Extract and Room temperatures."
    },
    {
      "address": 12,
      "count": 1,
      "name": "Number of minutes in ongoing support heating/cooling",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual. Cor_NeedRunTime, EXOL type I, Modbus address 12. Supply, Extract and Room temperatures."
    },
    {
      "address": 13,
      "count": 1,
      "name": "Supply air fan pressure (Pa)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFPressure, EXOL type R, Modbus address 13. SAF/EAF Pressure and Flow."
    },
    {
      "address": 14,
      "count": 1,
      "name": "Extract air fan pressure (Pa)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFPressure, EXOL type R, Modbus address 14. SAF/EAF Pressure and Flow."
    },
    {
      "address": 15,
      "count": 1,
      "name": "Supply air fan flow (m3/h). Scale factor = 1",
      "data_type": "Int16",
      "units": "m3/h",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFAirFlow, EXOL type R, Modbus address 15. SAF/EAF Pressure and Flow."
    },
    {
      "address": 16,
      "count": 1,
      "name": "Extract air fan flow (m3/h). Scale factor = 1",
      "data_type": "Int16",
      "units": "m3/h",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFAirFlow, EXOL type R, Modbus address 16. SAF/EAF Pressure and Flow."
    },
    {
      "address": 17,
      "count": 1,
      "name": "CO (ppm) 2",
      "data_type": "Int16",
      "units": "ppm",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_CO2Sensor, EXOL type R, Modbus address 17. CO 2."
    },
    {
      "address": 18,
      "count": 1,
      "name": "Number of minutes support run time CO 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_DemandRunTime, EXOL type I, Modbus address 18. CO 2."
    },
    {
      "address": 19,
      "count": 1,
      "name": "Frost protection temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_FrostprotectionTemp, EXOL type R, Modbus address 19. Frost protection."
    },
    {
      "address": 20,
      "count": 1,
      "name": "Exhaust air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExhaustAirTemp, EXOL type R, Modbus address 20. Extract air temp/De-icing exchanger."
    },
    {
      "address": 21,
      "count": 1,
      "name": "De-icing temp exchanger",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_DeIcingTemp, EXOL type R, Modbus address 21. Extract air temp/De-icing exchanger."
    },
    {
      "address": 22,
      "count": 1,
      "name": "Number of minutes for ongoing de-icing",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_DeIcingTime, EXOL type X, Modbus address 22. Extract air temp/De-icing exchanger."
    },
    {
      "address": 23,
      "count": 1,
      "name": "Humidity room",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HumidityRoom, EXOL type R, Modbus address 23. Humidity."
    },
    {
      "address": 24,
      "count": 1,
      "name": "Humidity duct",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HumidityDuct, EXOL type R, Modbus address 24. Humidity."
    },
    {
      "address": 25,
      "count": 1,
      "name": "Extra sensor 1/External setpoint (depending on configuration)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSensor, EXOL type R, Modbus address 25. Additional sensor/External setpoint."
    },
    {
      "address": 26,
      "count": 1,
      "name": "The scaled and filtered value of AI1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput1(0), EXOL type R, Modbus address 26. Analogue inputs."
    },
    {
      "address": 27,
      "count": 1,
      "name": "The scaled and filtered value of AI2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput2, EXOL type R, Modbus address 27. Analogue inputs."
    },
    {
      "address": 28,
      "count": 1,
      "name": "The scaled and filtered value of AI3",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput3, EXOL type R, Modbus address 28. Analogue inputs."
    },
    {
      "address": 29,
      "count": 1,
      "name": "The scaled and filtered value of AI4",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput4, EXOL type R, Modbus address 29. Analogue inputs."
    },
    {
      "address": 30,
      "count": 1,
      "name": "The scaled and filtered value of UAI1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput5, EXOL type R, Modbus address 30. Universal inputs."
    },
    {
      "address": 31,
      "count": 1,
      "name": "The scaled and filtered value of UAI2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput6, EXOL type R, Modbus address 31. Universal inputs."
    },
    {
      "address": 32,
      "count": 1,
      "name": "The scaled and filtered value of UAI3",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput7, EXOL type R, Modbus address 32. Universal inputs."
    },
    {
      "address": 33,
      "count": 1,
      "name": "The scaled and filtered value of UAI4",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_AnalogInput8, EXOL type R, Modbus address 33. Universal inputs."
    },
    {
      "address": 34,
      "count": 1,
      "name": "Connected signal on AI1: 0=Not used 1=Outdoor temp 2=Supplytemp 3=Extracttemp 4=Roomtemp1 5=Roomtemp2 6=Exhausttemp 7=Extrasensor 8=SAF pressure 9=EAF pressure 10=Deicingtemp 11=Frost pro...",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ai1(0), EXOL type X, Modbus address 34. Analogue inputs."
    },
    {
      "address": 35,
      "count": 1,
      "name": "Connected signal on AI2:",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ai2, EXOL type X, Modbus address 35. Analogue inputs."
    },
    {
      "address": 36,
      "count": 1,
      "name": "Connected signal on AI3:",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ai3, EXOL type X, Modbus address 36. Analogue inputs."
    },
    {
      "address": 37,
      "count": 1,
      "name": "Connected signal on AI4:",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ai4, EXOL type X, Modbus address 37. Analogue inputs."
    },
    {
      "address": 38,
      "count": 1,
      "name": "Connected signal on UAI1: 0=Not used 1=Outdoor temp 2=Supplytemp 3=Extracttemp 4=Roomtemp1 5=Roomtemp2 6=Exhausttemp 7=Extrasensor 8=SAF pressure 9=EAF pressure 10=Deicingtemp 11=Frost pr...",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UAi1, EXOL type X, Modbus address 38. Universal inputs."
    },
    {
      "address": 39,
      "count": 1,
      "name": "Connected signal on UAI2: (See signal list for UAI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UAi2, EXOL type X, Modbus address 39. Universal inputs."
    },
    {
      "address": 40,
      "count": 1,
      "name": "Connected signal on UAI3: (See signal list for UAI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UAi3, EXOL type X, Modbus address 40. Universal inputs."
    },
    {
      "address": 41,
      "count": 1,
      "name": "Connected signal on UAI4: (See signal list for UAI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UAi4, EXOL type X, Modbus address 41. Universal inputs."
    },
    {
      "address": 42,
      "count": 1,
      "name": "Connected signal on DI1: 0=Not used 1=SAF-Ind 2=EAF-Ind 3=P1-Heating 4=P1-Exchanger 5=P1-Cooling 6=Filter guard 7=Fire alarm 8=Fire damper-ind 9=Ext run 1/1 10=Ext run ½ 11=External alarm...",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di1(0), EXOL type X, Modbus address 42. Digital inputs."
    },
    {
      "address": 43,
      "count": 1,
      "name": "Connected signal on DI2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di2, EXOL type X, Modbus address 43. Digital inputs."
    },
    {
      "address": 44,
      "count": 1,
      "name": "Connected signal on DI3: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di3, EXOL type X, Modbus address 44. Digital inputs."
    },
    {
      "address": 45,
      "count": 1,
      "name": "Connected signal on DI4: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di4, EXOL type X, Modbus address 45. Digital inputs."
    },
    {
      "address": 46,
      "count": 1,
      "name": "Connected signal on DI5: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di5, EXOL type X, Modbus address 46. Digital inputs."
    },
    {
      "address": 47,
      "count": 1,
      "name": "Connected signal on DI6: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di6, EXOL type X, Modbus address 47. Digital inputs."
    },
    {
      "address": 48,
      "count": 1,
      "name": "Connected signal on DI7: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di7, EXOL type X, Modbus address 48. Digital inputs."
    },
    {
      "address": 49,
      "count": 1,
      "name": "Connected signal on DI8: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Di8, EXOL type X, Modbus address 49. Digital inputs."
    },
    {
      "address": 50,
      "count": 1,
      "name": "Connected signal on UDI1: 0=Not used 1=SAF-Ind 2=EAF-Ind 3=P1-Heating 4=P1-Exchanger 5=P1-Cooling 6=Filter guard 7=Fire alarm 8=Fire damper-ind 9=Ext run 1/1 10=Ext run ½ 11=External alar...",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UDi1, EXOL type X, Modbus address 50. Universal inputs."
    },
    {
      "address": 51,
      "count": 1,
      "name": "Connected signal on UDI2: (See signal list for UDI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UDi2, EXOL type X, Modbus address 51. Universal inputs."
    },
    {
      "address": 52,
      "count": 1,
      "name": "Connected signal on UDI3: (See signal list for UDI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UDi3, EXOL type X, Modbus address 52. Universal inputs."
    },
    {
      "address": 53,
      "count": 1,
      "name": "Connected signal on UDI4: (See signal list for UDI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_UDi4, EXOL type X, Modbus address 53. Universal inputs."
    },
    {
      "address": 54,
      "count": 1,
      "name": "Value of AO1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal QAnaOut.AQ1, EXOL type R, Modbus address 54. Analogue outputs."
    },
    {
      "address": 55,
      "count": 1,
      "name": "Value of AO2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal QAnaOut.AQ2, EXOL type R, Modbus address 55. Analogue outputs."
    },
    {
      "address": 56,
      "count": 1,
      "name": "Value of AO3",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal QAnaOut.AQ3, EXOL type R, Modbus address 56. Analogue outputs."
    },
    {
      "address": 57,
      "count": 1,
      "name": "Value of AO4",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal QAnaOut.AQ4, EXOL type R, Modbus address 57. Analogue outputs."
    },
    {
      "address": 58,
      "count": 1,
      "name": "Value of AO5",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal QAnaOut.AQ5, EXOL type R, Modbus address 58. Analogue outputs."
    },
    {
      "address": 59,
      "count": 1,
      "name": "Connected signal on AO1: 0=Not used 1=Y1-Heating 2=Y2-Exchanger 3=Y3-Cooling 4=SAF 5=EAF 6=Y6-Humidity 7=Split of Y1, Y2 or Y3 8=Extra unit 9=Heat/Cool (change over) 10=Extra sequence Y4",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ao1(0), EXOL type X, Modbus address 59. Analogue outputs."
    },
    {
      "address": 60,
      "count": 1,
      "name": "Connected signal on AO2: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ao2, EXOL type X, Modbus address 60. Analogue outputs."
    },
    {
      "address": 61,
      "count": 1,
      "name": "Connected signal on AO3: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ao3, EXOL type X, Modbus address 61. Analogue outputs."
    },
    {
      "address": 62,
      "count": 1,
      "name": "Connected signal on AO4: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ao4, EXOL type X, Modbus address 62. Analogue outputs."
    },
    {
      "address": 63,
      "count": 1,
      "name": "Connected signal on AO5: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Ao5, EXOL type X, Modbus address 63. Analogue outputs."
    },
    {
      "address": 64,
      "count": 1,
      "name": "Connected signal on DO1: 0 = Not Used 1 = SAFStart1 2 = EAFStart1 3 = SAFStart2 4 = EAFStart2 5 = HeatingPumpStart 6 = ExchangerStart 7 = CoolingPumpStart 8 = FireDamper 9 = SumAlarm 10 =...",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do1(0), EXOL type X, Modbus address 64. Digital outputs."
    },
    {
      "address": 65,
      "count": 1,
      "name": "Connected signal on DO2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do2, EXOL type X, Modbus address 65. Digital outputs."
    },
    {
      "address": 66,
      "count": 1,
      "name": "Connected signal on DO3: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do3, EXOL type X, Modbus address 66. Digital outputs."
    },
    {
      "address": 67,
      "count": 1,
      "name": "Connected signal on DO4: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do4, EXOL type X, Modbus address 67. Digital outputs."
    },
    {
      "address": 68,
      "count": 1,
      "name": "Connected signal on DO5: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do5, EXOL type X, Modbus address 68. Digital outputs."
    },
    {
      "address": 69,
      "count": 1,
      "name": "Connected signal on DO6: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do6, EXOL type X, Modbus address 69. Digital outputs."
    },
    {
      "address": 70,
      "count": 1,
      "name": "Connected signal on DO7: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_Do7, EXOL type X, Modbus address 70. Digital outputs."
    },
    {
      "address": 71,
      "count": 1,
      "name": "Run Error Supply Air Fan 0=Not used 1=Normal 2=Blocked 3=Acknowledge 4=Not used 5=Cancelled 6=Not used 7=Alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt1_Status, EXOL type X, Modbus address 71. Alarm Status."
    },
    {
      "address": 72,
      "count": 1,
      "name": "Run Error Extract Air Fan",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt2_Status, EXOL type X, Modbus address 72. Alarm Status."
    },
    {
      "address": 73,
      "count": 1,
      "name": "Run Error P1-Heater",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt3_Status, EXOL type X, Modbus address 73. Alarm Status."
    },
    {
      "address": 74,
      "count": 1,
      "name": "Run Error P1-Cooler",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt4_Status, EXOL type X, Modbus address 74. Alarm Status."
    },
    {
      "address": 75,
      "count": 1,
      "name": "Run Error P1-Exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt5_Status, EXOL type X, Modbus address 75. Alarm Status."
    },
    {
      "address": 76,
      "count": 1,
      "name": "Filter guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt6_Status, EXOL type X, Modbus address 76. Alarm Status."
    },
    {
      "address": 77,
      "count": 1,
      "name": "Flow guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt7_Status, EXOL type X, Modbus address 77. Alarm Status."
    },
    {
      "address": 78,
      "count": 1,
      "name": "External frost guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt8_Status, EXOL type X, Modbus address 78. Alarm Status."
    },
    {
      "address": 79,
      "count": 1,
      "name": "Deicing pressure guard",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt9_Status, EXOL type X, Modbus address 79. Alarm Status."
    },
    {
      "address": 80,
      "count": 1,
      "name": "Fire alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt10_Status, EXOL type X, Modbus address 80. Alarm Status."
    },
    {
      "address": 81,
      "count": 1,
      "name": "External switch",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt11_Status, EXOL type X, Modbus address 81. Alarm Status."
    },
    {
      "address": 82,
      "count": 1,
      "name": "External alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt12_Status, EXOL type X, Modbus address 82. Alarm Status."
    },
    {
      "address": 83,
      "count": 1,
      "name": "Supply Air control error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt13_Status, EXOL type X, Modbus address 83. Alarm Status."
    },
    {
      "address": 85,
      "count": 1,
      "name": "High supply air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt15_Status, EXOL type X, Modbus address 85. Alarm Status."
    },
    {
      "address": 86,
      "count": 1,
      "name": "Low supply air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt16_Status, EXOL type X, Modbus address 86. Alarm Status."
    },
    {
      "address": 87,
      "count": 1,
      "name": "Supply Air Fan max limit",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt17_Status, EXOL type X, Modbus address 87. Alarm Status."
    },
    {
      "address": 88,
      "count": 1,
      "name": "Supply Air Fan min limit",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt18_Status, EXOL type X, Modbus address 88. Alarm Status."
    },
    {
      "address": 89,
      "count": 1,
      "name": "High room temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt19_Status, EXOL type X, Modbus address 89. Alarm Status."
    },
    {
      "address": 90,
      "count": 1,
      "name": "Low room temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt20_Status, EXOL type X, Modbus address 90. Alarm Status."
    },
    {
      "address": 91,
      "count": 1,
      "name": "High extract air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt21_Status, EXOL type X, Modbus address 91. Alarm Status."
    },
    {
      "address": 92,
      "count": 1,
      "name": "Low extract air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt22_Status, EXOL type X, Modbus address 92. Alarm Status."
    },
    {
      "address": 93,
      "count": 1,
      "name": "Electric heating is overheated",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt23_Status, EXOL type X, Modbus address 93. Alarm Status."
    },
    {
      "address": 94,
      "count": 1,
      "name": "Frost risk",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt24_Status, EXOL type X, Modbus address 94. Alarm Status."
    },
    {
      "address": 95,
      "count": 1,
      "name": "Low frost guard temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt25_Status, EXOL type X, Modbus address 95. Alarm Status."
    },
    {
      "address": 96,
      "count": 1,
      "name": "Low efficiency",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt26_Status, EXOL type X, Modbus address 96. Alarm Status."
    },
    {
      "address": 97,
      "count": 1,
      "name": "Sensor error outdoor temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt27_Status, EXOL type X, Modbus address 97. Alarm Status."
    },
    {
      "address": 98,
      "count": 1,
      "name": "Analogue deicing",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt28_Status, EXOL type X, Modbus address 98. Alarm Status."
    },
    {
      "address": 99,
      "count": 1,
      "name": "Rotation guard exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt29_Status, EXOL type X, Modbus address 99. Alarm Status."
    },
    {
      "address": 100,
      "count": 1,
      "name": "Fire damper is out of operation",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt30_Status, EXOL type X, Modbus address 100. Alarm Status."
    },
    {
      "address": 101,
      "count": 1,
      "name": "Supply Air Fan control error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt31_Status, EXOL type X, Modbus address 101. Alarm Status."
    },
    {
      "address": 102,
      "count": 1,
      "name": "Extract Air Fan control error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt32_Status, EXOL type X, Modbus address 102. Alarm Status."
    },
    {
      "address": 103,
      "count": 1,
      "name": "Supply Air Fan external operation",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt33_Status, EXOL type X, Modbus address 103. Alarm Status."
    },
    {
      "address": 104,
      "count": 1,
      "name": "Extract Air Fan external operation",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt34_Status, EXOL type X, Modbus address 104. Alarm Status."
    },
    {
      "address": 105,
      "count": 1,
      "name": "Ventilation Manual mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt35_Status, EXOL type X, Modbus address 105. Alarm Status."
    },
    {
      "address": 106,
      "count": 1,
      "name": "Manual supply air control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt36_Status, EXOL type X, Modbus address 106. Alarm Status."
    },
    {
      "address": 107,
      "count": 1,
      "name": "Manual Supply Air Fan mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt37_Status, EXOL type X, Modbus address 107. Alarm Status."
    },
    {
      "address": 108,
      "count": 1,
      "name": "Manual Supply Air Fan freq. control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt38_Status, EXOL type X, Modbus address 108. Alarm Status."
    },
    {
      "address": 109,
      "count": 1,
      "name": "Manual Extract Air Fan mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt39_Status, EXOL type X, Modbus address 109. Alarm Status."
    },
    {
      "address": 110,
      "count": 1,
      "name": "Manual Extract Air Fan freq. control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt40_Status, EXOL type X, Modbus address 110. Alarm Status."
    },
    {
      "address": 111,
      "count": 1,
      "name": "Manual heater control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt41_Status, EXOL type X, Modbus address 111. Alarm Status."
    },
    {
      "address": 112,
      "count": 1,
      "name": "Manual cooler control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt42_Status, EXOL type X, Modbus address 112. Alarm Status."
    },
    {
      "address": 113,
      "count": 1,
      "name": "Manual exchanger control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt43_Status, EXOL type X, Modbus address 113. Alarm Status."
    },
    {
      "address": 114,
      "count": 1,
      "name": "Manual P1-Heater",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt44_Status, EXOL type X, Modbus address 114. Alarm Status."
    },
    {
      "address": 115,
      "count": 1,
      "name": "Manual P1-Cooler",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt45_Status, EXOL type X, Modbus address 115. Alarm Status."
    },
    {
      "address": 116,
      "count": 1,
      "name": "Manual P1-Exchanger",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt46_Status, EXOL type X, Modbus address 116. Alarm Status."
    },
    {
      "address": 117,
      "count": 1,
      "name": "Manual fire damper",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt47_Status, EXOL type X, Modbus address 117. Alarm Status."
    },
    {
      "address": 118,
      "count": 1,
      "name": "Internal battery error",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt48_Status, EXOL type X, Modbus address 118. Alarm Status."
    },
    {
      "address": 119,
      "count": 1,
      "name": "Control signal heating Y1 (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HeatCV1(0), EXOL type R, Modbus address 119. Analogue outputs."
    },
    {
      "address": 120,
      "count": 1,
      "name": "Control signal exchanger Y2 (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExchCV1, EXOL type R, Modbus address 120. Analogue outputs."
    },
    {
      "address": 121,
      "count": 1,
      "name": "Control signal cooler Y3 (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_CoolCV1, EXOL type R, Modbus address 121. Analogue outputs."
    },
    {
      "address": 122,
      "count": 1,
      "name": "Control signal supply air fan (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAF, EXOL type R, Modbus address 122. SAF/EAF Pressure and Flow."
    },
    {
      "address": 123,
      "count": 1,
      "name": "Control signal extract air fan (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAF, EXOL type R, Modbus address 123. SAF/EAF Pressure and Flow."
    },
    {
      "address": 124,
      "count": 1,
      "name": "Control signal humidity (0...10 V)",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_Humidity, EXOL type R, Modbus address 124. Humidity."
    },
    {
      "address": 125,
      "count": 1,
      "name": "Control signal split (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_Split, EXOL type R, Modbus address 125. Analogue outputs."
    },
    {
      "address": 126,
      "count": 1,
      "name": "Supply controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SupplyPID_Output, EXOL type R, Modbus address 126. Supply, Extract and Room temperatures."
    },
    {
      "address": 127,
      "count": 1,
      "name": "Extract controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExhaustPID_Output, EXOL type R, Modbus address 127. Supply, Extract and Room temperatures."
    },
    {
      "address": 128,
      "count": 1,
      "name": "SAF controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFPID_Output, EXOL type R, Modbus address 128. SAF/EAF Pressure and Flow."
    },
    {
      "address": 129,
      "count": 1,
      "name": "EAF controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFPID_Output, EXOL type R, Modbus address 129. SAF/EAF Pressure and Flow."
    },
    {
      "address": 130,
      "count": 1,
      "name": "Frost protection controller output if ventilation unit is stopped (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_FrostPID_Output, EXOL type R, Modbus address 130. Frost protection."
    },
    {
      "address": 131,
      "count": 1,
      "name": "CO controller output (0...100 %) 2",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_CO2PID_Output, EXOL type R, Modbus address 131. CO 2."
    },
    {
      "address": 132,
      "count": 1,
      "name": "Room controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_RoomPID_Output, EXOL type R, Modbus address 132. Supply, Extract and Room temperatures."
    },
    {
      "address": 133,
      "count": 1,
      "name": "De-icing controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_DeIcePID_Output, EXOL type R, Modbus address 133. Extract air temp/ De-icing exchanger."
    },
    {
      "address": 134,
      "count": 1,
      "name": "Humidity controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HumidityPID_Outpu t, EXOL type R, Modbus address 134. Humidity."
    },
    {
      "address": 135,
      "count": 1,
      "name": "Room temperature 1 and 2",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_RoomTemp, EXOL type R, Modbus address 135. Supply, Extract and Room temperatures."
    },
    {
      "address": 137,
      "count": 1,
      "name": "Sensor error Supply Air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt49_Status, EXOL type X, Modbus address 137. Alarm Status."
    },
    {
      "address": 138,
      "count": 1,
      "name": "Sensor error Exhaust Air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt50_Status, EXOL type X, Modbus address 138. Alarm Status."
    },
    {
      "address": 139,
      "count": 1,
      "name": "Sensor error Room temp 1",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt51_Status, EXOL type X, Modbus address 139. Alarm Status."
    },
    {
      "address": 140,
      "count": 1,
      "name": "Sensor error Room temp 2",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt52_Status, EXOL type X, Modbus address 140. Alarm Status."
    },
    {
      "address": 141,
      "count": 1,
      "name": "Sensor error Extract Air temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt53_Status, EXOL type X, Modbus address 141. Alarm Status."
    },
    {
      "address": 142,
      "count": 1,
      "name": "Sensor error Extra sensor",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt54_Status, EXOL type X, Modbus address 142. Alarm Status."
    },
    {
      "address": 143,
      "count": 1,
      "name": "Sensor error SAF pressure",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt55_Status, EXOL type X, Modbus address 143. Alarm Status."
    },
    {
      "address": 144,
      "count": 1,
      "name": "Sensor error EAF pressure",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt56_Status, EXOL type X, Modbus address 144. Alarm Status."
    },
    {
      "address": 145,
      "count": 1,
      "name": "Sensor error Deicing temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt57_Status, EXOL type X, Modbus address 145. Alarm Status."
    },
    {
      "address": 146,
      "count": 1,
      "name": "Sensor error Frost Protection temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt58_Status, EXOL type X, Modbus address 146. Alarm Status."
    },
    {
      "address": 147,
      "count": 1,
      "name": "Sensor error CO 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt59_Status, EXOL type X, Modbus address 147. Alarm Status."
    },
    {
      "address": 148,
      "count": 1,
      "name": "Sensor error Humidity room",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt60_Status, EXOL type X, Modbus address 148. Alarm Status."
    },
    {
      "address": 149,
      "count": 1,
      "name": "Sensor error Humidity duct",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt61_Status, EXOL type X, Modbus address 149. Alarm Status."
    },
    {
      "address": 150,
      "count": 1,
      "name": "Extra Unit temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraUnitTemp(0), EXOL type R, Modbus address 150. Extra Unit."
    },
    {
      "address": 151,
      "count": 1,
      "name": "External SAF signal control (%)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtSAFControl, EXOL type R, Modbus address 151. SAF/EAF Pressure and Flow."
    },
    {
      "address": 152,
      "count": 1,
      "name": "External EAF signal control (%)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtEAFControl, EXOL type R, Modbus address 152. SAF/EAF Pressure and Flow."
    },
    {
      "address": 153,
      "count": 1,
      "name": "Pressure transmitter 2 supply air (Pa)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual. Cor_SAFPressure2, EXOL type R, Modbus address 153. SAF/EAF Pressure and Flow."
    },
    {
      "address": 155,
      "count": 1,
      "name": "Humidity outdoor",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HumidityOutDoor, EXOL type R, Modbus address 155. Humidity."
    },
    {
      "address": 156,
      "count": 1,
      "name": "Sensor error Extra unit temp",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt62_Status, EXOL type X, Modbus address 156. Alarm Status."
    },
    {
      "address": 157,
      "count": 1,
      "name": "Sensor error External control SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt63_Status, EXOL type X, Modbus address 157. Alarm Status."
    },
    {
      "address": 158,
      "count": 1,
      "name": "Sensor error External control EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt64_Status, EXOL type X, Modbus address 158. Alarm Status."
    },
    {
      "address": 159,
      "count": 1,
      "name": "Sensor error SAF Pressure 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt65_Status, EXOL type X, Modbus address 159. Alarm Status."
    },
    {
      "address": 160,
      "count": 1,
      "name": "Sensor error Humidity Outdoor",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt66_Status, EXOL type X, Modbus address 160. Alarm Status."
    },
    {
      "address": 161,
      "count": 1,
      "name": "Sensor error Reserved 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt67_Status, EXOL type X, Modbus address 161. Alarm Status."
    },
    {
      "address": 162,
      "count": 1,
      "name": "Sensor error Reserved 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt68_Status, EXOL type X, Modbus address 162. Alarm Status."
    },
    {
      "address": 163,
      "count": 1,
      "name": "Sensor error Reserved 3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt69_Status, EXOL type X, Modbus address 163. Alarm Status."
    },
    {
      "address": 164,
      "count": 1,
      "name": "Sensor error Reserved 4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt70_Status, EXOL type X, Modbus address 164. Alarm Status."
    },
    {
      "address": 165,
      "count": 1,
      "name": "Sensor error Reserved 5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt71_Status, EXOL type X, Modbus address 165. Alarm Status."
    },
    {
      "address": 166,
      "count": 1,
      "name": "Sensor error Reserved 6",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt72_Status, EXOL type X, Modbus address 166. Alarm Status."
    },
    {
      "address": 167,
      "count": 1,
      "name": "Sensor error Reserved 7",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt73_Status, EXOL type X, Modbus address 167. Alarm Status."
    },
    {
      "address": 168,
      "count": 1,
      "name": "Sensor error Reserved 8",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt74_Status, EXOL type X, Modbus address 168. Alarm Status."
    },
    {
      "address": 169,
      "count": 1,
      "name": "Sensor error Reserved 9",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt75_Status, EXOL type X, Modbus address 169. Alarm Status."
    },
    {
      "address": 170,
      "count": 1,
      "name": "Sensor error Reserved 10",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt76_Status, EXOL type X, Modbus address 170. Alarm Status."
    },
    {
      "address": 171,
      "count": 1,
      "name": "Alarm Frequency Converter SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt77_Status, EXOL type X, Modbus address 171. Alarm Status."
    },
    {
      "address": 172,
      "count": 1,
      "name": "Alarm Frequency Converter EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt78_Status, EXOL type X, Modbus address 172. Alarm Status."
    },
    {
      "address": 173,
      "count": 1,
      "name": "Communication error Frequency SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt79_Status, EXOL type X, Modbus address 173. Alarm Status."
    },
    {
      "address": 174,
      "count": 1,
      "name": "Communication error Frequency EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt80_Status, EXOL type X, Modbus address 174. Alarm Status."
    },
    {
      "address": 175,
      "count": 1,
      "name": "Communication error Expansion unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt81_Status, EXOL type X, Modbus address 175. Alarm Status."
    },
    {
      "address": 176,
      "count": 1,
      "name": "Communication error Expansion unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt82_Status, EXOL type X, Modbus address 176. Alarm Status."
    },
    {
      "address": 177,
      "count": 1,
      "name": "Warning Frequency Converter SAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt83_Status, EXOL type X, Modbus address 177. Alarm Status."
    },
    {
      "address": 178,
      "count": 1,
      "name": "Warning Frequency Converter EAF",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt84_Status, EXOL type X, Modbus address 178. Alarm Status."
    },
    {
      "address": 179,
      "count": 1,
      "name": "Output in manual mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt85_Status, EXOL type X, Modbus address 179. Alarm Status."
    },
    {
      "address": 180,
      "count": 1,
      "name": "Time for service",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt86_Status, EXOL type X, Modbus address 180. Alarm Status."
    },
    {
      "address": 181,
      "count": 1,
      "name": "Manual Y4-Extra Sequence control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt87_Status, EXOL type X, Modbus address 181. Alarm Status."
    },
    {
      "address": 182,
      "count": 1,
      "name": "The scaled and filtered value of AI1 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(0), EXOL type R, Modbus address 182. Analogue inputs."
    },
    {
      "address": 183,
      "count": 1,
      "name": "The scaled and filtered value of AI2 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(1), EXOL type R, Modbus address 183. Analogue inputs."
    },
    {
      "address": 184,
      "count": 1,
      "name": "The scaled and filtered value of AI3 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(2), EXOL type R, Modbus address 184. Analogue inputs."
    },
    {
      "address": 185,
      "count": 1,
      "name": "The scaled and filtered value of AI4 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(3), EXOL type R, Modbus address 185. Analogue inputs."
    },
    {
      "address": 186,
      "count": 1,
      "name": "The scaled and filtered value of UAI1 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(4), EXOL type R, Modbus address 186. Universal inputs."
    },
    {
      "address": 187,
      "count": 1,
      "name": "The scaled and filtered value of UAI2 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(5), EXOL type R, Modbus address 187. Universal inputs."
    },
    {
      "address": 188,
      "count": 1,
      "name": "The scaled and filtered value of UAI3 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(6), EXOL type R, Modbus address 188. Universal inputs."
    },
    {
      "address": 189,
      "count": 1,
      "name": "The scaled and filtered value of UAI3 Exp.Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(7), EXOL type R, Modbus address 189. Universal inputs."
    },
    {
      "address": 190,
      "count": 1,
      "name": "The scaled and filtered value of AI1 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(8), EXOL type R, Modbus address 190. Analogue inputs."
    },
    {
      "address": 191,
      "count": 1,
      "name": "The scaled and filtered value of AI2 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(9), EXOL type R, Modbus address 191. Analogue inputs."
    },
    {
      "address": 192,
      "count": 1,
      "name": "The scaled and filtered value of AI3 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(10), EXOL type R, Modbus address 192. Analogue inputs."
    },
    {
      "address": 193,
      "count": 1,
      "name": "The scaled and filtered value of AI4 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(11), EXOL type R, Modbus address 193. Analogue inputs."
    },
    {
      "address": 194,
      "count": 1,
      "name": "The scaled and filtered value of UAI1 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(12), EXOL type R, Modbus address 194. Universal inputs."
    },
    {
      "address": 195,
      "count": 1,
      "name": "The scaled and filtered value of UAI2 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(13), EXOL type R, Modbus address 195. Universal inputs."
    },
    {
      "address": 196,
      "count": 1,
      "name": "The scaled and filtered value of UAI3 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(14), EXOL type R, Modbus address 196. Universal inputs."
    },
    {
      "address": 197,
      "count": 1,
      "name": "The scaled and filtered value of UAI3 Exp.Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExpAnalogInput(15), EXOL type R, Modbus address 197. Universal inputs."
    },
    {
      "address": 198,
      "count": 1,
      "name": "Connected signal on AI1 Exp. Unit 1: 0=Not used 1=Outdoor temp 2=Supplytemp 3=Extracttemp 4=Roomtemp1 5=Roomtemp2 6=Exhausttemp 7=Extrasensor 8=SAF pressure 9=EAF pressure 10=Deicingtemp...",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(0), EXOL type X, Modbus address 198. Analogue inputs."
    },
    {
      "address": 199,
      "count": 1,
      "name": "Connected signal on AI2 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(1), EXOL type X, Modbus address 199. Analogue inputs."
    },
    {
      "address": 200,
      "count": 1,
      "name": "Connected signal on AI3 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(2), EXOL type X, Modbus address 200. Analogue inputs."
    },
    {
      "address": 201,
      "count": 1,
      "name": "Connected signal on AI4 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(3), EXOL type X, Modbus address 201. Analogue inputs."
    },
    {
      "address": 202,
      "count": 1,
      "name": "Connected signal on UAI1 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(4), EXOL type X, Modbus address 202. Analogue inputs."
    },
    {
      "address": 203,
      "count": 1,
      "name": "Connected signal on UAI2 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(5), EXOL type X, Modbus address 203. Analogue inputs."
    },
    {
      "address": 204,
      "count": 1,
      "name": "Connected signal on UAI3 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(6), EXOL type X, Modbus address 204. Analogue inputs."
    },
    {
      "address": 205,
      "count": 1,
      "name": "Connected signal on UAI4 Exp. Unit 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(7), EXOL type X, Modbus address 205. Analogue inputs."
    },
    {
      "address": 206,
      "count": 1,
      "name": "Connected signal on AI1 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(8), EXOL type X, Modbus address 206. Analogue inputs."
    },
    {
      "address": 207,
      "count": 1,
      "name": "Connected signal on AI2 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(9), EXOL type X, Modbus address 207. Analogue inputs."
    },
    {
      "address": 208,
      "count": 1,
      "name": "Connected signal on AI3 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(10), EXOL type X, Modbus address 208. Analogue inputs."
    },
    {
      "address": 209,
      "count": 1,
      "name": "Connected signal on AI4 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(11), EXOL type X, Modbus address 209. Analogue inputs."
    },
    {
      "address": 210,
      "count": 1,
      "name": "Connected signal on UAI1 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(12), EXOL type X, Modbus address 210. Analogue inputs."
    },
    {
      "address": 211,
      "count": 1,
      "name": "Connected signal on UAI2 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(13), EXOL type X, Modbus address 211. Analogue inputs."
    },
    {
      "address": 212,
      "count": 1,
      "name": "Connected signal on UAI3 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(14), EXOL type X, Modbus address 212. Analogue inputs."
    },
    {
      "address": 213,
      "count": 1,
      "name": "Connected signal on UAI4 Exp. Unit 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAi(15), EXOL type X, Modbus address 213. Analogue inputs."
    },
    {
      "address": 214,
      "count": 1,
      "name": "Connected signal on DI1 Exp. Unit 1: 0=Not used 1=SAF-Ind 2=EAF-Ind 3=P1-Heating 4=P1-Exchanger 5=P1-Cooling 6=Filter guard 7=Fire alarm 8=Fire damper-ind 9=Ext run 1/1 10=Ext run ½ 11=Ex...",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(0), EXOL type X, Modbus address 214. Digital inputs."
    },
    {
      "address": 215,
      "count": 1,
      "name": "Connected signal on DI2 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(1), EXOL type X, Modbus address 215. Digital inputs."
    },
    {
      "address": 216,
      "count": 1,
      "name": "Connected signal on DI3 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(2), EXOL type X, Modbus address 216. Digital inputs."
    },
    {
      "address": 217,
      "count": 1,
      "name": "Connected signal on DI4 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(3), EXOL type X, Modbus address 217. Digital inputs."
    },
    {
      "address": 218,
      "count": 1,
      "name": "Connected signal on DI5 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(4), EXOL type X, Modbus address 218. Digital inputs."
    },
    {
      "address": 219,
      "count": 1,
      "name": "Connected signal on DI6 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(5), EXOL type X, Modbus address 219. Digital inputs."
    },
    {
      "address": 220,
      "count": 1,
      "name": "Connected signal on DI7 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(6), EXOL type X, Modbus address 220. Digital inputs."
    },
    {
      "address": 221,
      "count": 1,
      "name": "Connected signal on DI8 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(7), EXOL type X, Modbus address 221. Digital inputs."
    },
    {
      "address": 222,
      "count": 1,
      "name": "Connected signal on UDI1 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(8), EXOL type X, Modbus address 222. Digital inputs."
    },
    {
      "address": 223,
      "count": 1,
      "name": "Connected signal on UDI2 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(9), EXOL type X, Modbus address 223. Digital inputs."
    },
    {
      "address": 224,
      "count": 1,
      "name": "Connected signal on UDI3 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(10), EXOL type X, Modbus address 224. Digital inputs."
    },
    {
      "address": 225,
      "count": 1,
      "name": "Connected signal on UDI4 Exp. Unit 1: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(11), EXOL type X, Modbus address 225. Digital inputs."
    },
    {
      "address": 226,
      "count": 1,
      "name": "Connected signal on DI1 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(12), EXOL type X, Modbus address 226. Digital inputs."
    },
    {
      "address": 227,
      "count": 1,
      "name": "Connected signal on DI2 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(13), EXOL type X, Modbus address 227. Digital inputs."
    },
    {
      "address": 228,
      "count": 1,
      "name": "Connected signal on DI3 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(14), EXOL type X, Modbus address 228. Digital inputs."
    },
    {
      "address": 229,
      "count": 1,
      "name": "Connected signal on DI4 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(15), EXOL type X, Modbus address 229. Digital inputs."
    },
    {
      "address": 230,
      "count": 1,
      "name": "Connected signal on DI5 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(16), EXOL type X, Modbus address 230. Digital inputs."
    },
    {
      "address": 231,
      "count": 1,
      "name": "Connected signal on DI6 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(17), EXOL type X, Modbus address 231. Digital inputs."
    },
    {
      "address": 232,
      "count": 1,
      "name": "Connected signal on DI7 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(18), EXOL type X, Modbus address 232. Digital inputs."
    },
    {
      "address": 233,
      "count": 1,
      "name": "Connected signal on DI8 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(19), EXOL type X, Modbus address 233. Digital inputs."
    },
    {
      "address": 234,
      "count": 1,
      "name": "Connected signal on UDI1 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(20), EXOL type X, Modbus address 234. Digital inputs."
    },
    {
      "address": 235,
      "count": 1,
      "name": "Connected signal on UDI2 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(21), EXOL type X, Modbus address 235. Digital inputs."
    },
    {
      "address": 236,
      "count": 1,
      "name": "Connected signal on UDI3 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(22), EXOL type X, Modbus address 236. Digital inputs."
    },
    {
      "address": 237,
      "count": 1,
      "name": "Connected signal on UDI4 Exp. Unit 2: (See signal list for DI1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDi(23), EXOL type X, Modbus address 237. Digital inputs."
    },
    {
      "address": 238,
      "count": 1,
      "name": "Value of AO1 Exp. Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1AnaOut1, EXOL type R, Modbus address 238. Analogue outputs."
    },
    {
      "address": 239,
      "count": 1,
      "name": "Value of AO2 Exp. Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1AnaOut2, EXOL type R, Modbus address 239. Analogue outputs."
    },
    {
      "address": 240,
      "count": 1,
      "name": "Value of AO3 Exp. Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1AnaOut3, EXOL type R, Modbus address 240. Analogue outputs."
    },
    {
      "address": 241,
      "count": 1,
      "name": "Value of AO4 Exp. Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1AnaOut4, EXOL type R, Modbus address 241. Analogue outputs."
    },
    {
      "address": 242,
      "count": 1,
      "name": "Value of AO5 Exp. Unit 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp1AnaOut5, EXOL type R, Modbus address 242. Analogue outputs."
    },
    {
      "address": 243,
      "count": 1,
      "name": "Value of AO1 Exp. Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2AnaOut1, EXOL type R, Modbus address 243. Analogue outputs."
    },
    {
      "address": 244,
      "count": 1,
      "name": "Value of AO2 Exp. Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2AnaOut2, EXOL type R, Modbus address 244. Analogue outputs."
    },
    {
      "address": 245,
      "count": 1,
      "name": "Value of AO3 Exp. Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2AnaOut3, EXOL type R, Modbus address 245. Analogue outputs."
    },
    {
      "address": 246,
      "count": 1,
      "name": "Value of AO4 Exp. Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2AnaOut4, EXOL type R, Modbus address 246. Analogue outputs."
    },
    {
      "address": 247,
      "count": 1,
      "name": "Value of AO5 Exp. Unit 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal InputOutput.Exp2AnaOut5, EXOL type R, Modbus address 247. Analogue outputs."
    },
    {
      "address": 248,
      "count": 1,
      "name": "Connected signal on AO1 Exp. Unit 1: 0=Not used 1=Y1-Heating 2=Y2-Exchanger 3=Y3-Cooling 4=SAF 5=EAF 6=Y6-Humidity 7=Split of Y1, Y2 or Y3 8=Extra unit 9=Heat/Cool (change over) 10=Extra...",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(0), EXOL type X, Modbus address 248. Analogue outputs."
    },
    {
      "address": 249,
      "count": 1,
      "name": "Connected signal on AO2 Exp. Unit 1: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(1), EXOL type X, Modbus address 249. Analogue outputs."
    },
    {
      "address": 250,
      "count": 1,
      "name": "Connected signal on AO3 Exp. Unit 1: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(2), EXOL type X, Modbus address 250. Analogue outputs."
    },
    {
      "address": 251,
      "count": 1,
      "name": "Connected signal on AO4 Exp. Unit 1: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(3), EXOL type X, Modbus address 251. Analogue outputs."
    },
    {
      "address": 252,
      "count": 1,
      "name": "Connected signal on AO5 Exp. Unit 1: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(4), EXOL type X, Modbus address 252. Analogue outputs."
    },
    {
      "address": 253,
      "count": 1,
      "name": "Connected signal on AO1 Exp. Unit 2: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(5), EXOL type X, Modbus address 253. Analogue outputs."
    },
    {
      "address": 254,
      "count": 1,
      "name": "Connected signal on AO2 Exp. Unit 2: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(6), EXOL type X, Modbus address 254. Analogue outputs."
    },
    {
      "address": 255,
      "count": 1,
      "name": "Connected signal on AO3 Exp. Unit 2: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(7), EXOL type X, Modbus address 255. Analogue outputs."
    },
    {
      "address": 256,
      "count": 1,
      "name": "Connected signal on AO4 Exp. Unit 2: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(8), EXOL type X, Modbus address 256. Analogue outputs."
    },
    {
      "address": 257,
      "count": 1,
      "name": "Connected signal on AO5 Exp. Unit 2: (See signal list for AO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpAo(9), EXOL type X, Modbus address 257. Analogue outputs."
    },
    {
      "address": 258,
      "count": 1,
      "name": "Connected signal on DO1 Exp. Unit 1: 0 = Not Used 1 = SAFStart1 2 = EAFStart1 3 = SAFStart2 4 = EAFStart2 5 = HeatingPumpStart 6 = ExchangerStart 7 = CoolingPumpStart 8 = FireDamper 9 = S...",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(0), EXOL type X, Modbus address 258. Digital outputs."
    },
    {
      "address": 259,
      "count": 1,
      "name": "Connected signal on DO2 Exp. Unit 1: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(1), EXOL type X, Modbus address 259. Digital outputs."
    },
    {
      "address": 260,
      "count": 1,
      "name": "Connected signal on DO3 Exp. Unit 1: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(2), EXOL type X, Modbus address 260. Digital outputs."
    },
    {
      "address": 261,
      "count": 1,
      "name": "Connected signal on DO4 Exp. Unit 1: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(3), EXOL type X, Modbus address 261. Digital outputs."
    },
    {
      "address": 262,
      "count": 1,
      "name": "Connected signal on DO5 Exp. Unit 1: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(4), EXOL type X, Modbus address 262. Digital outputs."
    },
    {
      "address": 263,
      "count": 1,
      "name": "Connected signal on DO6 Exp. Unit 1: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(5), EXOL type X, Modbus address 263. Digital outputs."
    },
    {
      "address": 264,
      "count": 1,
      "name": "Connected signal on DO7 Exp. Unit 1: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(6), EXOL type X, Modbus address 264. Digital outputs."
    },
    {
      "address": 265,
      "count": 1,
      "name": "Connected signal on DO1 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(7), EXOL type X, Modbus address 265. Digital outputs."
    },
    {
      "address": 266,
      "count": 1,
      "name": "Connected signal on DO2 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(8), EXOL type X, Modbus address 266. Digital outputs."
    },
    {
      "address": 267,
      "count": 1,
      "name": "Connected signal on DO3 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(9), EXOL type X, Modbus address 267. Digital outputs."
    },
    {
      "address": 268,
      "count": 1,
      "name": "Connected signal on DO4 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(10), EXOL type X, Modbus address 268. Digital outputs."
    },
    {
      "address": 269,
      "count": 1,
      "name": "Connected signal on DO5 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(11), EXOL type X, Modbus address 269. Digital outputs."
    },
    {
      "address": 270,
      "count": 1,
      "name": "Connected signal on DO6 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(12), EXOL type X, Modbus address 270. Digital outputs."
    },
    {
      "address": 271,
      "count": 1,
      "name": "Connected signal on DO7 Exp. Unit 2: (See signal list for DO1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentSettings.Cor_ExpDo(13), EXOL type X, Modbus address 271. Digital outputs."
    },
    {
      "address": 272,
      "count": 1,
      "name": "SAF Motor speed Hz (Vacon)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFMotorSpeedHz, EXOL type R, Modbus address 272. SAF/EAF Pressure and Flow."
    },
    {
      "address": 273,
      "count": 1,
      "name": "SAF Motor current A (Vacon)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFMotorCurrent, EXOL type R, Modbus address 273. SAF/EAF Pressure and Flow."
    },
    {
      "address": 274,
      "count": 1,
      "name": "SAF Motor Power % of nominal (Vacon)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFMotorPower, EXOL type R, Modbus address 274. SAF/EAF Pressure and Flow."
    },
    {
      "address": 275,
      "count": 1,
      "name": "SAF Accumulated Power consumption (Vacon)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SAFAccumPower, EXOL type R, Modbus address 275. SAF/EAF Pressure and Flow."
    },
    {
      "address": 276,
      "count": 1,
      "name": "EAF Motor speed Hz (Vacon)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFMotorSpeedHz, EXOL type R, Modbus address 276. SAF/EAF Pressure and Flow."
    },
    {
      "address": 277,
      "count": 1,
      "name": "EAF Motor current A (Vacon)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFMotorCurrent, EXOL type R, Modbus address 277. SAF/EAF Pressure and Flow."
    },
    {
      "address": 278,
      "count": 1,
      "name": "EAF Motor Power % of nominal (Vacon)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFMotorPower, EXOL type R, Modbus address 278. SAF/EAF Pressure and Flow."
    },
    {
      "address": 279,
      "count": 1,
      "name": "EAF Accumulated Power consuption (Vacon)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_EAFAccumPower, EXOL type R, Modbus address 279. SAF/EAF Pressure and Flow."
    },
    {
      "address": 280,
      "count": 1,
      "name": "Control signal Extra Unit (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraUnitCV1(0), EXOL type R, Modbus address 280. Extra Unit."
    },
    {
      "address": 281,
      "count": 1,
      "name": "Extra Unit controller output (0...100 %)",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraUnitPID1_Outp ut(0), EXOL type R, Modbus address 281. Extra Unit."
    },
    {
      "address": 282,
      "count": 1,
      "name": "Control signal Heating or Cooling controlled by changeover (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_HeatCoolCV1, EXOL type R, Modbus address 282. Analogue outputs."
    },
    {
      "address": 283,
      "count": 1,
      "name": "Control signal extra sequence Y4 (0...10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSeqCV1, EXOL type R, Modbus address 283. Analogue outputs."
    },
    {
      "address": 284,
      "count": 1,
      "name": "Unit run mode: 0=Off 1=Reduced speed 2=Normal speed 3=Stop because of alarm",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_UnitRunMode, EXOL type X, Modbus address 284. Actual/Setpoint."
    },
    {
      "address": 285,
      "count": 1,
      "name": "Restart blocked after power-on",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt88_Status, EXOL type X, Modbus address 285. Alarm Status."
    },
    {
      "address": 286,
      "count": 1,
      "name": "Intake air temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_IntakeAirTemp, EXOL type R, Modbus address 286. Actual/Setpoint."
    },
    {
      "address": 287,
      "count": 1,
      "name": "Extrasensor 2 temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSensor2, EXOL type R, Modbus address 287. Actual/Setpoint."
    },
    {
      "address": 288,
      "count": 1,
      "name": "Extrasensor 3 temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSensor3, EXOL type R, Modbus address 288. Actual/Setpoint."
    },
    {
      "address": 289,
      "count": 1,
      "name": "Extrasensor 4 temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSensor4, EXOL type R, Modbus address 289. Actual/Setpoint."
    },
    {
      "address": 290,
      "count": 1,
      "name": "Extrasensor 5 temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSensor5, EXOL type R, Modbus address 290. Actual/Setpoint."
    },
    {
      "address": 291,
      "count": 1,
      "name": "Extrasensor SAF Pressure",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSAFPressure, EXOL type R, Modbus address 291. SAF/EAF Pressure and Flow."
    },
    {
      "address": 292,
      "count": 1,
      "name": "Extrasensor EAF Pressure",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraEAFPressure, EXOL type R, Modbus address 292. SAF/EAF Pressure and Flow."
    },
    {
      "address": 296,
      "count": 1,
      "name": "Control valve Extra sequence Y5 (0…10 V)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_ExtraSeqY5, EXOL type R, Modbus address 296. Analogue outputs."
    },
    {
      "address": 297,
      "count": 1,
      "name": "Manual Y5-Extra Sequence",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal AlaData.AlaPt89_Status, EXOL type X, Modbus address 297. Alarm Status."
    },
    {
      "address": 298,
      "count": 1,
      "name": "Actual SFP (kW/m3/s)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SFP, EXOL type R, Modbus address 298. SFP (Specific Fan Power)."
    },
    {
      "address": 299,
      "count": 1,
      "name": "Day average SFP",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SFPDay, EXOL type R, Modbus address 299. SFP (Specific Fan Power)."
    },
    {
      "address": 300,
      "count": 1,
      "name": "Month average (30 day average) SFP",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_SFPMonth, EXOL type R, Modbus address 300. SFP (Specific Fan Power)."
    }
  ],
  "holding_registers": [
    {
      "address": 1,
      "count": 1,
      "name": "Setpoint supply air temperature when constant supply air temperature function",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplySetpoin t, EXOL type R, Modbus address 1, default value 18°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 2,
      "count": 1,
      "name": "Outdoor temp for first curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X1, EXOL type R, Modbus address 2, default value -20°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 4,
      "count": 1,
      "name": "Outdoor temp for third curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X3, EXOL type R, Modbus address 4, default value -10°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 5,
      "count": 1,
      "name": "Outdoor temp for fourth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X4, EXOL type R, Modbus address 5, default value -5°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 6,
      "count": 1,
      "name": "Outdoor temp for fifth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X5, EXOL type R, Modbus address 6, default value 0°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 7,
      "count": 1,
      "name": "Outdoor temp for sixth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X6, EXOL type R, Modbus address 7, default value 5°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 8,
      "count": 1,
      "name": "Outdoor temp for seventh curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X7, EXOL type R, Modbus address 8, default value 10°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 9,
      "count": 1,
      "name": "Outdoor temp for eighth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_X8, EXOL type R, Modbus address 9, default value 15°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 10,
      "count": 1,
      "name": "Setpoint for first curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y1, EXOL type R, Modbus address 10, default value 25°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 12,
      "count": 1,
      "name": "Setpoint for third curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y3, EXOL type R, Modbus address 12, default value 23°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 13,
      "count": 1,
      "name": "Setpoint for fourth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y4, EXOL type R, Modbus address 13, default value 23°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 14,
      "count": 1,
      "name": "Setpoint for fifth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y5, EXOL type R, Modbus address 14, default value 22°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 15,
      "count": 1,
      "name": "Setpoint for sixth curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y6, EXOL type R, Modbus address 15, default value 20°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 16,
      "count": 1,
      "name": "Setpoint for seventh curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y7, EXOL type R, Modbus address 16, default value 18°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 17,
      "count": 1,
      "name": "Setpoint for eight curve point for outdoor compensated setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Curve1_Y8, EXOL type R, Modbus address 17, default value 18°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 18,
      "count": 1,
      "name": "Setpoint extract air temp if extract air temp control function",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExhaustSetpoi nt, EXOL type R, Modbus address 18, default value 21°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 19,
      "count": 1,
      "name": "Room setpoint if room temp control function",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RoomSetP, EXOL type R, Modbus address 19, default value 21°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 20,
      "count": 1,
      "name": "Room temp for start the unit if intermittent heating control is active",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NeedHeatStart, EXOL type R, Modbus address 20, default value 15°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 21,
      "count": 1,
      "name": "Room temp for stop the unit if intermittent heating control is active",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NeedHeatStop, EXOL type R, Modbus address 21, default value 21°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 22,
      "count": 1,
      "name": "Room temp for start the unit if intermittent cooling control is active",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NeedCoolStar t, EXOL type R, Modbus address 22, default value 30°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 23,
      "count": 1,
      "name": "Room temp for stop the unit if intermittent cooling control is active",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NeedCoolStop, EXOL type R, Modbus address 23, default value 28°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 24,
      "count": 1,
      "name": "Setpoint full speed supply air fan pressure",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFFullspeed Pressure, EXOL type R, Modbus address 24, default value 500 Pa. SAF/EAF Pressure and Flow."
    },
    {
      "address": 25,
      "count": 1,
      "name": "Setpoint reduced speed supply air fan pressure",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFHalfspeed Pressure, EXOL type R, Modbus address 25, default value 250 Pa. SAF/EAF Pressure and Flow."
    },
    {
      "address": 26,
      "count": 1,
      "name": "Setpoint full speed extract air fan pressure",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFFullspeed Pressure, EXOL type R, Modbus address 26, default value 500 Pa. SAF/EAF Pressure and Flow."
    },
    {
      "address": 27,
      "count": 1,
      "name": "Setpoint reduced speed extract air fan pressure",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFHalfspee dPressure, EXOL type R, Modbus address 27, default value 250 Pa. SAF/EAF Pressure and Flow."
    },
    {
      "address": 28,
      "count": 1,
      "name": "Setpoint full speed supply air fan flow. Scale factor = 1",
      "data_type": "Int16",
      "units": "m3/h",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFFullspeed AirFlow, EXOL type R, Modbus address 28, default value 2000 m3/h. SAF/EAF Pressure and Flow."
    },
    {
      "address": 29,
      "count": 1,
      "name": "Setpoint reduced speed supply air fan flow. Scale factor = 1",
      "data_type": "Int16",
      "units": "m3/h",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFHalfspeed AirFlow, EXOL type R, Modbus address 29, default value 1000 m3/h. SAF/EAF Pressure and Flow."
    },
    {
      "address": 30,
      "count": 1,
      "name": "Setpoint full speed extract air fan flow. Scale factor = 1",
      "data_type": "Int16",
      "units": "m3/h",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFFullspeed AirFlow, EXOL type R, Modbus address 30, default value 2000 m3/h. SAF/EAF Pressure and Flow."
    },
    {
      "address": 31,
      "count": 1,
      "name": "Setpoint reduced speed extract air fan flow. Scale factor = 1",
      "data_type": "Int16",
      "units": "m3/h",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFHalfspee dAirFlow, EXOL type R, Modbus address 31, default value 1000 m3/h. SAF/EAF Pressure and Flow."
    },
    {
      "address": 32,
      "count": 1,
      "name": "Setpoint CO 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CO2Setpoint, EXOL type R, Modbus address 32, default value 1000 ppm. CO 2."
    },
    {
      "address": 33,
      "count": 1,
      "name": "Setpoint frost protection if the ventilation unit is stopped",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FrostProtSPSt op, EXOL type R, Modbus address 33, default value 25°C. Frost protection."
    },
    {
      "address": 34,
      "count": 1,
      "name": "P-Gain frost protection when running (alarm limit+PGain)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FrostProtPGai n, EXOL type R, Modbus address 34, default value 5°C. Frost protection."
    },
    {
      "address": 35,
      "count": 1,
      "name": "Setpoint de-icing temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DeIcingSetpoi nt, EXOL type R, Modbus address 35, default value -3°C. Extract air temp/Deicing exchanger."
    },
    {
      "address": 36,
      "count": 1,
      "name": "Hysteresis for stop of de-icing",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DeIcingHyst, EXOL type R, Modbus address 36, default value 1°C. Extract air temp/Deicing exchanger."
    },
    {
      "address": 37,
      "count": 1,
      "name": "Setpoint humidity room",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumiditySetp oint, EXOL type R, Modbus address 37, default value 50 % RH. Humidity."
    },
    {
      "address": 38,
      "count": 1,
      "name": "Max limit humidity duct",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityMax Duct, EXOL type R, Modbus address 38, default value 80 % RH. Humidity."
    },
    {
      "address": 39,
      "count": 1,
      "name": "Hysteresis to start humidity control after stop max limitation",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityHyst, EXOL type R, Modbus address 39, default value 20 % RH. Humidity."
    },
    {
      "address": 312,
      "count": 1,
      "name": "P-band supply air control",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplyPID_P Gain, EXOL type R, Modbus address 312, default value 33°C. Settings, Control Temp."
    },
    {
      "address": 314,
      "count": 1,
      "name": "P-band extract air control",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExhaustPID_P Gain, EXOL type R, Modbus address 314, default value 100° C. Settings, Control Temp."
    },
    {
      "address": 316,
      "count": 1,
      "name": "P-band room air control",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RoomPID_PG ain, EXOL type R, Modbus address 316, default value 100° C. Settings, Control Temp."
    },
    {
      "address": 318,
      "count": 1,
      "name": "P-band switchdown mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FrostPID_PGa in, EXOL type R, Modbus address 318, default value 100° C. Settings, Control Temp."
    },
    {
      "address": 320,
      "count": 1,
      "name": "P-band de-icing",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DeIcePID_PG ain, EXOL type R, Modbus address 320, default value 100° C. Settings, Control Temp."
    },
    {
      "address": 322,
      "count": 1,
      "name": "P-band pressure control SAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFPID_PGa in, EXOL type R, Modbus address 322, default value 500 Pa. Settings, Control Pressure."
    },
    {
      "address": 324,
      "count": 1,
      "name": "P-band pressure control EAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFPID_PGa in, EXOL type R, Modbus address 324, default value 500 Pa. Settings, Control Pressure."
    },
    {
      "address": 330,
      "count": 1,
      "name": "P-band humidity control",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityPID _PGain, EXOL type R, Modbus address 330, default value 100 % RH. Settings, Control Humidity."
    },
    {
      "address": 332,
      "count": 1,
      "name": "Max control deviation supply air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplyMaxDi ff, EXOL type R, Modbus address 332, default value 10°C. Settings, Alarm Limits."
    },
    {
      "address": 333,
      "count": 1,
      "name": "High alarm limit supply air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplyHighAl armLimit, EXOL type R, Modbus address 333, default value 30°C. Settings, Alarm Limits."
    },
    {
      "address": 334,
      "count": 1,
      "name": "Low alarm limit supply air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplyLowAl armLimit, EXOL type R, Modbus address 334, default value 10°C. Settings, Alarm Limits."
    },
    {
      "address": 335,
      "count": 1,
      "name": "High alarm limit extract air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExhaustAirTe mpHigh, EXOL type R, Modbus address 335, default value 30°C. Settings, Alarm Limits."
    },
    {
      "address": 336,
      "count": 1,
      "name": "Low alarm limit extract air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExhaustAirTe mpLow, EXOL type R, Modbus address 336, default value 10°C. Settings, Alarm Limits."
    },
    {
      "address": 337,
      "count": 1,
      "name": "High alarm limit room air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RoomHighLi mit, EXOL type R, Modbus address 337, default value 30°C. Settings, Alarm Limits."
    },
    {
      "address": 338,
      "count": 1,
      "name": "Low alarm limit room air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RoomLowLi mit, EXOL type R, Modbus address 338, default value 10°C. Settings, Alarm Limits."
    },
    {
      "address": 339,
      "count": 1,
      "name": "Alarm limit frost protection",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FrostLimit, EXOL type R, Modbus address 339, default value 7°C. Settings, Alarm Limits."
    },
    {
      "address": 340,
      "count": 1,
      "name": "Max control deviation pressure SAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFMaxDiffP ressure, EXOL type R, Modbus address 340, default value 50 Pa. Settings, Alarm Limits."
    },
    {
      "address": 341,
      "count": 1,
      "name": "Max control deviation pressure EAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFMaxDiff Pressure, EXOL type R, Modbus address 341, default value 50 Pa. Settings, Alarm Limits."
    },
    {
      "address": 342,
      "count": 1,
      "name": "Low efficiency",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EfficiencyLo wLimit, EXOL type R, Modbus address 342, default value 50 %. Settings, Alarm Limits."
    },
    {
      "address": 343,
      "count": 1,
      "name": "Alarm delay control deviation supply air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt13_DelayValue, EXOL type I, Modbus address 343, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 344,
      "count": 1,
      "name": "Alarm delay high supply air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt15_DelayValue, EXOL type I, Modbus address 344, default value 5 s. Settings, Alarm Delays."
    },
    {
      "address": 345,
      "count": 1,
      "name": "Alarm delay low supply air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt16_DelayValue, EXOL type I, Modbus address 345, default value 5 s. Settings, Alarm Delays."
    },
    {
      "address": 346,
      "count": 1,
      "name": "Alarm delay high extract air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt21_DelayValue, EXOL type I, Modbus address 346, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 347,
      "count": 1,
      "name": "Alarm delay low extract air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt22_DelayValue, EXOL type I, Modbus address 347, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 348,
      "count": 1,
      "name": "Alarm delay high room air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt19_DelayValue, EXOL type I, Modbus address 348, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 349,
      "count": 1,
      "name": "Alarm delay low alarm room air temp",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt20_DelayValue, EXOL type I, Modbus address 349, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 350,
      "count": 1,
      "name": "Alarm delay frost protection",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt25_DelayValue, EXOL type I, Modbus address 350, default value 0 s. Settings, Alarm Delays."
    },
    {
      "address": 351,
      "count": 1,
      "name": "Alarm delay max control deviation pressure SAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt31_DelayValue, EXOL type I, Modbus address 351, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 352,
      "count": 1,
      "name": "Alarm delay max control deviation pressure EAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt32_DelayValue, EXOL type I, Modbus address 352, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 353,
      "count": 1,
      "name": "Alarm delay low efficiency",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt26_DelayValue, EXOL type I, Modbus address 353, default value 30 min. Settings, Alarm Delays."
    },
    {
      "address": 354,
      "count": 1,
      "name": "Alarm delay malfunction SAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt1_DelayValue, EXOL type I, Modbus address 354, default value 120 s. Settings, Alarm Delays."
    },
    {
      "address": 355,
      "count": 1,
      "name": "Alarm delay malfunction EAF",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt2_DelayValue, EXOL type I, Modbus address 355, default value 120 s. Settings, Alarm Delays."
    },
    {
      "address": 356,
      "count": 1,
      "name": "Alarm delay malfunction P1-Heating",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt3_DelayValue, EXOL type I, Modbus address 356, default value 5 s. Settings, Alarm Delays."
    },
    {
      "address": 357,
      "count": 1,
      "name": "Alarm delay malfunction P1-Cooling",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt4_DelayValue, EXOL type I, Modbus address 357, default value 5 s. Settings, Alarm Delays."
    },
    {
      "address": 358,
      "count": 1,
      "name": "Alarm delay malfunction P1-Exchanger",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt5_DelayValue, EXOL type I, Modbus address 358, default value 20 s. Settings, Alarm Delays."
    },
    {
      "address": 359,
      "count": 1,
      "name": "Alarm delay filter monitoring",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt6_DelayValue, EXOL type I, Modbus address 359, default value 180 s. Settings, Alarm Delays."
    },
    {
      "address": 360,
      "count": 1,
      "name": "Alarm delay flow switch",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt7_DelayValue, EXOL type I, Modbus address 360, default value 5 s. Settings, Alarm Delays."
    },
    {
      "address": 361,
      "count": 1,
      "name": "Alarm delay frost protection",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt8_DelayValue, EXOL type I, Modbus address 361, default value 0 s. Settings, Alarm Delays."
    },
    {
      "address": 362,
      "count": 1,
      "name": "Alarm delay frost protection digital input",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt9_DelayValue, EXOL type I, Modbus address 362, default value 0 s. Settings, Alarm Delays."
    },
    {
      "address": 363,
      "count": 1,
      "name": "Alarm delay fire alarm",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt10_DelayValue, EXOL type I, Modbus address 363, default value 0 s. Settings, Alarm Delays."
    },
    {
      "address": 364,
      "count": 1,
      "name": "Alarm delay external alarm",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt12_DelayValue, EXOL type I, Modbus address 364, default value 0 s. Settings, Alarm Delays."
    },
    {
      "address": 365,
      "count": 1,
      "name": "Alarm delay electric heater",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt23_DelayValue, EXOL type I, Modbus address 365, default value 0 s. Settings, Alarm Delays."
    },
    {
      "address": 366,
      "count": 1,
      "name": "Alarm delay sensor error",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt27_DelayValue, EXOL type I, Modbus address 366, default value 5 s. Settings, Alarm Delays."
    },
    {
      "address": 367,
      "count": 1,
      "name": "Alarm delay rotation guard exchanger",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal AlaData.AlaPt29_DelayValue, EXOL type I, Modbus address 367, default value 20 s. Settings, Alarm Delays."
    },
    {
      "address": 368,
      "count": 1,
      "name": "Running mode air unit: 0=Manual off 1=Manual reduced speed 2=Manual normal speed 3=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_AirUnitAuto Mode, EXOL type X, Modbus address 368, default value 3. Manual/Auto."
    },
    {
      "address": 369,
      "count": 1,
      "name": "Supply temp controller mode: 0=Manual off 1=Manual on 2=Auto",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplyPID_S elect, EXOL type X, Modbus address 369, default value 2. Manual/Auto."
    },
    {
      "address": 370,
      "count": 1,
      "name": "Supply temp controller output if manual on mode",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplyPID_M anSet, EXOL type R, Modbus address 370, default value 0 %. Manual/Auto."
    },
    {
      "address": 371,
      "count": 1,
      "name": "Running mode SAF: 0=Off 1=Manual half speed 2=Manual full speed 3=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFAutoMod e(0), EXOL type X, Modbus address 371, default value 3. Manual/Auto."
    },
    {
      "address": 372,
      "count": 1,
      "name": "Running mode EAF: 0=Off 1=Manual half speed 2=Manual full speed 3=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFAutoMod e, EXOL type X, Modbus address 372, default value 3. Manual/Auto."
    },
    {
      "address": 373,
      "count": 1,
      "name": "Running mode frequence controlled SAF 0=Manual 1=Man. half speed 2=Man. Fullspeed 3=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFFrequenc eAutoMode, EXOL type X, Modbus address 373, default value 3. Manual/Auto."
    },
    {
      "address": 374,
      "count": 1,
      "name": "Freguencer controller output SAF if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFManual, EXOL type R, Modbus address 374, default value 0 %. Manual/Auto."
    },
    {
      "address": 375,
      "count": 1,
      "name": "Running mode frequence controlled EAF 0=Manual 1=Man. half speed 2=Man. Fullspeed 3=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFFrequenc eAutoMode, EXOL type X, Modbus address 375, default value 3. Manual/Auto."
    },
    {
      "address": 376,
      "count": 1,
      "name": "Freguencer controller output EAF if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFManual, EXOL type R, Modbus address 376, default value 0 %. Manual/Auto."
    },
    {
      "address": 377,
      "count": 1,
      "name": "Running mode Heating: 0=Off 1=Manual 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HeatCoilAuto Mode(0), EXOL type X, Modbus address 377, default value 2. Manual/Auto."
    },
    {
      "address": 378,
      "count": 1,
      "name": "Heating controller output if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HeatCoilMan ual(0), EXOL type R, Modbus address 378, default value 0. Manual/Auto."
    },
    {
      "address": 379,
      "count": 1,
      "name": "Running mode Exchanger: 0=Off 1=Manual 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExchCoilAuto Mode, EXOL type X, Modbus address 379, default value 2. Manual/Auto."
    },
    {
      "address": 380,
      "count": 1,
      "name": "Exchanger controller output if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExchCoilMan ual, EXOL type R, Modbus address 380, default value 0. Manual/Auto."
    },
    {
      "address": 381,
      "count": 1,
      "name": "Running mode Cooling: 0=Off 1=Manual 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolCoilAuto Mode, EXOL type X, Modbus address 381, default value 2. Manual/Auto."
    },
    {
      "address": 382,
      "count": 1,
      "name": "Cooling controller output if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolCoilMan ual, EXOL type R, Modbus address 382, default value 0. Manual/Auto."
    },
    {
      "address": 383,
      "count": 1,
      "name": "Running mode Humidification/Dehumidification: 0=Off 1=Manual 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityPID _Select, EXOL type X, Modbus address 383, default value 2. Manual/Auto."
    },
    {
      "address": 384,
      "count": 1,
      "name": "Humidification/Dehumidification controller output if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityPID _ManSet, EXOL type R, Modbus address 384, default value 0. Manual/Auto."
    },
    {
      "address": 385,
      "count": 1,
      "name": "Running mode P1-Heating: 0=Manual off 1=Manual on 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HeatPumpAut oMode(0), EXOL type X, Modbus address 385, default value 2. Manual/Auto."
    },
    {
      "address": 386,
      "count": 1,
      "name": "Running mode P1-Exchanger: 0=Manual off 1=Manual on 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExchPumpAut oMode, EXOL type X, Modbus address 386, default value 2. Manual/Auto."
    },
    {
      "address": 387,
      "count": 1,
      "name": "Running mode P1-Cooling: 0=Manual off 1=Manual on 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolPumpAut oMode, EXOL type X, Modbus address 387, default value 2. Manual/Auto."
    },
    {
      "address": 388,
      "count": 1,
      "name": "Running mode fire damper: 0=Close 1=Open 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FireDamperA utoMode, EXOL type X, Modbus address 388, default value 2. Manual/Auto."
    },
    {
      "address": 389,
      "count": 1,
      "name": "Running mode fresh air damper: 0=Close 1=Open 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FreshAirDampe rAutoMode, EXOL type X, Modbus address 389, default value 2. Manual/Auto."
    },
    {
      "address": 390,
      "count": 1,
      "name": "Running mode recirculation damper: 0=Close 1=Open 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleAirDam perAutoMode, EXOL type X, Modbus address 390, default value 2. Manual/Auto."
    },
    {
      "address": 391,
      "count": 1,
      "name": "Running mode extract air damper: 0=Close 1=Open 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtractAirDamp erAutoMode, EXOL type X, Modbus address 391, default value 2. Manual/Auto."
    },
    {
      "address": 392,
      "count": 1,
      "name": "Outdoor temperature (Can be modified if it’s not connected to a physical analogue input).",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "Signal VentActual.Cor_Outdoor temp(0), EXOL type R, Modbus address 392. Actual/Setpoint."
    },
    {
      "address": 393,
      "count": 1,
      "name": "Manual/Auto Full Speed time channel 0=Manual-Off 1=Manual-On 2=Forced Off 3=Forced On 4=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusFanF ullSpeed, EXOL type X, Modbus address 393, default value 4. Manual/Auto."
    },
    {
      "address": 394,
      "count": 1,
      "name": "Manual/Auto Half Speed time channel 0=Manual-Off 1=Manual-On 2=Forced Off 3=Forced On 4=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusFanH alfSpeed, EXOL type X, Modbus address 394, default value 4. Manual/Auto."
    },
    {
      "address": 395,
      "count": 1,
      "name": "Manual/Auto Timer output 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusCor_ ExtraTimeGroup1, EXOL type X, Modbus address 395, default value 4. Manual/Auto."
    },
    {
      "address": 396,
      "count": 1,
      "name": "Manual/Auto Timer output 2 0=Manual-Off 1=Manual-On 2=Forced Off 3=Forced On 4=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusCor_ ExtraTimeGroup2, EXOL type X, Modbus address 396, default value 4. Manual/Auto."
    },
    {
      "address": 397,
      "count": 1,
      "name": "Manual/Auto Timer output 3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusCor_ ExtraTimeGroup3, EXOL type X, Modbus address 397, default value 4. Manual/Auto."
    },
    {
      "address": 398,
      "count": 1,
      "name": "Manual/Auto Timer output 4 0=Manual-Off 1=Manual-On 2=Forced Off 3=Forced On 4=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusCor_ ExtraTimeGroup4, EXOL type X, Modbus address 398, default value 4. Manual/Auto."
    },
    {
      "address": 399,
      "count": 1,
      "name": "Manual/Auto Timer output 5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal TimePro.TimeGroupStatusCor_ ExtraTimeGroup5, EXOL type X, Modbus address 399, default value 4. Manual/Auto."
    },
    {
      "address": 400,
      "count": 1,
      "name": "External alarm acknowledge by setting this signal to the alarm number that should be acknowledge.",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal Alarms.AlaAcknow, EXOL type X, Modbus address 400, default value 255. Alarm Acknowledging, Blocking and Unblocking."
    },
    {
      "address": 401,
      "count": 1,
      "name": "External alarm blocking by setting this signal to the alarm number that should be blocked.",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal Alarms.AlaBlock, EXOL type X, Modbus address 401, default value 255. Alarm Acknowledging, Blocking and Unblocking."
    },
    {
      "address": 402,
      "count": 1,
      "name": "External alarm unblocking by setting this signal to the alarm number that should be unblocked.",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal Alarms.AlaUnBlock, EXOL type X, Modbus address 402, default value 255. Alarm Acknowledging, Blocking and Unblocking."
    },
    {
      "address": 403,
      "count": 1,
      "name": "If lower outdoor temp the heating pump is not stopped",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HeatPumpLim it, EXOL type R, Modbus address 403, default value 10°C. Actual/Setpoint."
    },
    {
      "address": 404,
      "count": 1,
      "name": "Max limit of supply setpoint when cascade control",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplySetpoin tMax, EXOL type R, Modbus address 404, default value 30°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 405,
      "count": 1,
      "name": "Min limit of supply setpoint when cascade control",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SupplySetpoin tMin, EXOL type R, Modbus address 405, default value 12°C. Supply, Extract and Room temperatures."
    },
    {
      "address": 406,
      "count": 1,
      "name": "Real time clock: Second 0-59",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Sec, EXOL type X, Modbus address 406. Real Time Clock."
    },
    {
      "address": 407,
      "count": 1,
      "name": "Real time clock: Minute 0-59",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Minute, EXOL type X, Modbus address 407. Real Time Clock."
    },
    {
      "address": 408,
      "count": 1,
      "name": "Real time clock: Hour 0-23",
      "data_type": "UInt16",
      "units": "h",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Hour, EXOL type X, Modbus address 408. Real Time Clock."
    },
    {
      "address": 409,
      "count": 1,
      "name": "Real time clock: Day of Week 1-7, 1=Monday",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.WDay, EXOL type X, Modbus address 409. Real Time Clock."
    },
    {
      "address": 410,
      "count": 1,
      "name": "Real time clock: Week number 1-53",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Week, EXOL type X, Modbus address 410. Real Time Clock."
    },
    {
      "address": 411,
      "count": 1,
      "name": "Real time clock: Day of month 1-31",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Date, EXOL type X, Modbus address 411. Real Time Clock."
    },
    {
      "address": 412,
      "count": 1,
      "name": "Real time clock: Month 1-12",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Month, EXOL type X, Modbus address 412. Real Time Clock."
    },
    {
      "address": 413,
      "count": 1,
      "name": "Real time clock: Year 0-99",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signal QSystem.Year, EXOL type X, Modbus address 413. Real Time Clock."
    },
    {
      "address": 414,
      "count": 1,
      "name": "Pressure compensation at breakpoint 1",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Comp1Pressur e, EXOL type R, Modbus address 414, default value 0. SAF/EAF Pressure and Flow."
    },
    {
      "address": 415,
      "count": 1,
      "name": "Outdoor temp breakpoint 1 (must be lower than breakpoint 2 temp)",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings. Cor_Comp1Temp, EXOL type R, Modbus address 415, default value -20. SAF/EAF Pressure and Flow."
    },
    {
      "address": 416,
      "count": 1,
      "name": "Pressure compensation at breakpoint 2",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Comp2Pressur e, EXOL type R, Modbus address 416, default value 0. SAF/EAF Pressure and Flow."
    },
    {
      "address": 417,
      "count": 1,
      "name": "Outdoor temp breakpoint 2 (must be higher than breakpoint 1 temp)",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_Comp2Temp, EXOL type R, Modbus address 417, default value 10. SAF/EAF Pressure and Flow."
    },
    {
      "address": 418,
      "count": 1,
      "name": "Max allowed difference between setpoint and humidity in room before alarm",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityMax Diff, EXOL type R, Modbus address 418, default value 10 % RH. Humidity."
    },
    {
      "address": 419,
      "count": 1,
      "name": "Start limit in % to start digital output signal \"Cor_HumidityStart(0)\"",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityStart Limit, EXOL type R, Modbus address 419, default value 15 % RH. Humidity."
    },
    {
      "address": 420,
      "count": 1,
      "name": "Stop limit in % to stop digital output signal \"Cor_HumidityStart(0)\"",
      "data_type": "Int16",
      "units": "%RH",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityStop Limit, EXOL type R, Modbus address 420, default value 5 % RH. Humidity."
    },
    {
      "address": 421,
      "count": 1,
      "name": "Running mode humidity start signal 0=Off 1=On 2=Auto",
      "data_type": "UInt16",
      "units": "%RH",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HumidityAuto Mode, EXOL type X, Modbus address 421, default value 2. Manual/Auto."
    },
    {
      "address": 422,
      "count": 1,
      "name": "Start delay Exchanger (s)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExchStartDela y, EXOL type I, Modbus address 422, default value 0 s. Settings, General."
    },
    {
      "address": 423,
      "count": 1,
      "name": "If lower outdoor temperature all steps for DX- cooling is blocked",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DXBlockLimi t, EXOL type R, Modbus address 423, default value 0°C. Settings, General."
    },
    {
      "address": 424,
      "count": 1,
      "name": "Output signal (0...100 %) full speed SAF if Frequency control manually",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFFullspeed Output, EXOL type R, Modbus address 424, default value 75 %. SAF/EAF Pressure and Flow."
    },
    {
      "address": 425,
      "count": 1,
      "name": "Output signal (0...100 %) half speed SAF if Frequency control manually",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_SAFHalfspeed Output, EXOL type R, Modbus address 425, default value 50 %. SAF/EAF Pressure and Flow."
    },
    {
      "address": 426,
      "count": 1,
      "name": "Output signal (0...100 %) full speed EAF if Frequency control manually",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFFullspeed Output, EXOL type R, Modbus address 426, default value 75 %. SAF/EAF Pressure and Flow."
    },
    {
      "address": 427,
      "count": 1,
      "name": "Output signal (0...100 %) half speed EAF if Frequency control manually",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFHalfspee dOutput, EXOL type R, Modbus address 427, default value 50 %. SAF/EAF Pressure and Flow."
    },
    {
      "address": 428,
      "count": 1,
      "name": "If frequens output signal SAF is lower cool step 1 is blocked",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepBloc k1, EXOL type R, Modbus address 428, default value 0 %. Settings, General."
    },
    {
      "address": 429,
      "count": 1,
      "name": "If frequens output signal SAF is lower cool step 2 is blocked",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepBloc k2, EXOL type R, Modbus address 429, default value 0 %. Settings, General."
    },
    {
      "address": 430,
      "count": 1,
      "name": "If frequens output signal SAF is lower cool step 3 is blocked",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepBloc k3, EXOL type R, Modbus address 430, default value 0 %. Settings, General."
    },
    {
      "address": 431,
      "count": 1,
      "name": "If lower outdoor temperature Cool step 1 is blocked",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepBloc kLimit1(0), EXOL type R, Modbus address 431, default value 13°C. Settings, General."
    },
    {
      "address": 432,
      "count": 1,
      "name": "If lower outdoor temperature Cool step 2 is blocked",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepBloc kLimit2, EXOL type R, Modbus address 432, default value 13°C. Settings, General."
    },
    {
      "address": 433,
      "count": 1,
      "name": "If lower outdoor temperature Cool step 3 is blocked",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolStepBloc kLimit3, EXOL type R, Modbus address 433, default value 13°C. Settings, General."
    },
    {
      "address": 434,
      "count": 1,
      "name": "Start/Stop function Extra Unit: 0=Off 1=Always running 2=Running if unit is running",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraUnitFun c, EXOL type X, Modbus address 434, default value 0. Extra Unit."
    },
    {
      "address": 435,
      "count": 1,
      "name": "Setpoint Extra Unit",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraUnitSetP, EXOL type R, Modbus address 435, default value 18°C. Extra Unit."
    },
    {
      "address": 436,
      "count": 1,
      "name": "Control mode Extra Unit 0=Heating Controller 1=Cooling Controller",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraUnitPID 1Mode, EXOL type X, Modbus address 436, default value 0. Extra Unit."
    },
    {
      "address": 437,
      "count": 1,
      "name": "Manual/Auto Extra Unit Controller 0=Off 1=Manual 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraUnitPID 1_Select(0), EXOL type X, Modbus address 437, default value 2. Manual/Auto."
    },
    {
      "address": 438,
      "count": 1,
      "name": "Extra Unit Controller output if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraUnitPID 1_ManSet(0), EXOL type R, Modbus address 438, default value 0. Manual/Auto."
    },
    {
      "address": 439,
      "count": 1,
      "name": "Recirculation setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleSetP, EXOL type R, Modbus address 439, default value 18°C. Recirculation."
    },
    {
      "address": 440,
      "count": 1,
      "name": "If higher room temp when Recirculation run recirculation damper is closed and fresh air damper is opened",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleMaxR oomTemp, EXOL type R, Modbus address 440, default value 25°C. Recirculation."
    },
    {
      "address": 447,
      "count": 1,
      "name": "Factor for controlling EAF if CAV fan control is configured (EAF is controlled by SAF with this factor)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_EAFFrequenc yFact, EXOL type R, Modbus address 447, default value 1. SAF/EAF Pressure and Flow."
    },
    {
      "address": 448,
      "count": 1,
      "name": "Manual/Auto Extra Sequence Y4 0=Off 1=Manual 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraSeqCoil AutoMode, EXOL type X, Modbus address 448, default value 2. Manual/Auto."
    },
    {
      "address": 449,
      "count": 1,
      "name": "Extra Sequence Y4 output if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraSeqCoil Manual, EXOL type R, Modbus address 449, default value 0. Manual/Auto."
    },
    {
      "address": 450,
      "count": 1,
      "name": "Time in month between filter exchange (Service Alarm)",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FilterAlarmTi me, EXOL type I, Modbus address 450, default value 0. Settings, Alarm Delays."
    },
    {
      "address": 451,
      "count": 1,
      "name": "External control: 0=Extended run full speed 1=External stop 2=No external control 3=External stop with support control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExternalContr ol, EXOL type X, Modbus address 451, default value 2. Manual/Auto."
    },
    {
      "address": 452,
      "count": 1,
      "name": "If outdoor temp. is lower, preheat is activated",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreHeatStart, EXOL type R, Modbus address 452, default value 8. Settings, PreTreatment."
    },
    {
      "address": 453,
      "count": 1,
      "name": "If outdoor temp. is higher, precool is activated",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreCoolStart, EXOL type R, Modbus address 453, default value 19. Settings, PreTreatment."
    },
    {
      "address": 454,
      "count": 1,
      "name": "Hysteresis to start/stop pretreatment",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreTreatHyst, EXOL type R, Modbus address 454, default value 1. Settings, PreTreatment."
    },
    {
      "address": 455,
      "count": 1,
      "name": "Min. diff. intake air temp. and outdoor air temp.",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreTreatMinD iff, EXOL type R, Modbus address 455, default value 1. Settings, PreTreatment."
    },
    {
      "address": 456,
      "count": 1,
      "name": "Run mode pretreatment: 0=Closed 1=Open 2=Auto",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreTreatment AutoMode, EXOL type X, Modbus address 456, default value 2. Settings, PreTreatment."
    },
    {
      "address": 457,
      "count": 1,
      "name": "Select whether pretreatment should be activated during free cooling",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreTreatFreeC ool, EXOL type X, Modbus address 457, default value 0. Settings, PreTreatment."
    },
    {
      "address": 458,
      "count": 1,
      "name": "Hour that pretreatment is blocked if diff. intake/outdoor is too low",
      "data_type": "UInt16",
      "units": "h",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreTreatBlock Time, EXOL type X, Modbus address 458, default value 6. Settings, PreTreatment."
    },
    {
      "address": 459,
      "count": 1,
      "name": "Min. runtime (minutes) for pretreatment",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_PreTreatMinR unTime, EXOL type X, Modbus address 459, default value 5. Settings, PreTreatment."
    },
    {
      "address": 460,
      "count": 1,
      "name": "Automatic restart after power-up (=1)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RestartPower On, EXOL type X, Modbus address 460, default value 1. Settings, General."
    },
    {
      "address": 461,
      "count": 1,
      "name": "Switch to full speed if DX-Cooling",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DXFullSpeed, EXOL type X, Modbus address 461, default value 0. Settings, General."
    },
    {
      "address": 462,
      "count": 1,
      "name": "Offset for recirculation setpoint",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleSetPO ffset, EXOL type R, Modbus address 462, default value 0. Recirculation."
    },
    {
      "address": 463,
      "count": 1,
      "name": "Select if constant setpoint or setpoint adjustment when recirculation runs: 0=Constant setpoint 1=Supply air setpoint with adjustment",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleSetPC ontrol, EXOL type X, Modbus address 463, default value 0. Recirculation."
    },
    {
      "address": 464,
      "count": 1,
      "name": "Enable supply air temp control when recirculation runs: 0=No temp control 1=Heating/cooling 2=Only heating 3=Only cooling",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_RecycleTemp Control, EXOL type X, Modbus address 464, default value 0. Recirculation."
    },
    {
      "address": 465,
      "count": 1,
      "name": "Activation of demand-controlled ventilation, 1/2- speed",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DemandCO2 Value1, EXOL type R, Modbus address 465, default value 800. CO 2."
    },
    {
      "address": 466,
      "count": 1,
      "name": "Activation of demand-controlled ventilation, 1/1- speed",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DemandCO2 Value2, EXOL type R, Modbus address 466, default value 1000. CO 2."
    },
    {
      "address": 467,
      "count": 1,
      "name": "Hysteresis for stop of demand controlled ventilation (ppm)",
      "data_type": "Int16",
      "units": "ppm",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_DemandCO2 Diff, EXOL type R, Modbus address 467, default value 160. CO 2."
    },
    {
      "address": 468,
      "count": 1,
      "name": "Outdoor temp for switching between outdoor compensated or cascade control if Cor_VentControl = 4 or 5 (if higher outdoor temp then cascade control)",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CascadeTemp, EXOL type R, Modbus address 468, default value 13. Supply, Extract and Room temperatures."
    },
    {
      "address": 469,
      "count": 1,
      "name": "Run mode Extra seq coil Y5 (0=Off, 1=Manual, 2=Auto)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraSeqY5A utoMode, EXOL type X, Modbus address 469, default value 2. Manual/Auto."
    },
    {
      "address": 470,
      "count": 1,
      "name": "Manual setting Extra seq coil Y5 if manual mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraSeqY5M anual, EXOL type R, Modbus address 470, default value 0. Manual/Auto."
    },
    {
      "address": 471,
      "count": 1,
      "name": "Min. limit for Y5 in Auto mode",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExtraSeqY5M in, EXOL type R, Modbus address 471, default value 0. Actual/Setpoint."
    },
    {
      "address": 472,
      "count": 1,
      "name": "Temperature setpoint offset in reduced speed",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ReducedSetP Offset, EXOL type R, Modbus address 472, default value 0. Actual/Setpoint."
    },
    {
      "address": 473,
      "count": 1,
      "name": "Select change-over external (0=Heating, 1=Cooling, 2=Auto)",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ChangeOverS elect, EXOL type X, Modbus address 473, default value 2. Settings, General."
    },
    {
      "address": 474,
      "count": 1,
      "name": "Select temperature control mode: 0=Const. supply air 1=Outdoor compensated supply air 2=Cascade room temp control 3=Extract temp control 4=Outdoor dependent supply or room temp 5=Outdoor...",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_VentControl, EXOL type X, Modbus address 474, default value 0. Settings, General."
    },
    {
      "address": 475,
      "count": 1,
      "name": "Select fan control mode: 0=1-Speed. 1=2-Speed. 2=Frequency control pressure 3=Frequency control air flow 4=Frequency control manually 5=Direct frequency control 6=Frequency control with s...",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_FanType, EXOL type X, Modbus address 475, default value 0. Settings, General."
    },
    {
      "address": 476,
      "count": 1,
      "name": "Type of heating: 0=Water 1=Electric 2=Not connected 3=Both water and electric",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_HeatType, EXOL type X, Modbus address 476, default value 0. Settings, General."
    },
    {
      "address": 477,
      "count": 1,
      "name": "Type of cooling: 0=Water 1=DX 2=Not connected 3=DX with exchange control",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_CoolType, EXOL type X, Modbus address 477, default value 0. Settings, General."
    },
    {
      "address": 478,
      "count": 1,
      "name": "Type of heat exchanger: 0=Damper 1=Rot.exchanger 2=Plate exchanger 3=Liquid exchanger 4=Not connected",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_ExchType, EXOL type X, Modbus address 478, default value 2. Settings, General."
    },
    {
      "address": 480,
      "count": 1,
      "name": "If outdoor temp. is higher at night, free cooling is stopped",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolHig hLimit, EXOL type R, Modbus address 480, default value 18. Settings, Free cooling."
    },
    {
      "address": 481,
      "count": 1,
      "name": "If outdoor temp is lower at night, free cooling is stopped",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolLo wLimit, EXOL type R, Modbus address 481, default value 10. Settings, Free cooling."
    },
    {
      "address": 482,
      "count": 1,
      "name": "If room temp is lower at night, free cooling is stopped",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolRoo mLimit, EXOL type R, Modbus address 482, default value 18. Settings, Free cooling."
    },
    {
      "address": 483,
      "count": 1,
      "name": "Start time free cool function",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolStar tTime, EXOL type X, Modbus address 483, default value 0. Settings, Free cooling."
    },
    {
      "address": 484,
      "count": 1,
      "name": "Stop time free cool function",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolSto pTime, EXOL type X, Modbus address 484, default value 7. Settings, Free cooling."
    },
    {
      "address": 485,
      "count": 1,
      "name": "Time in minutes to block heat output when starting after running free cooling",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolHea tBlockTime, EXOL type I, Modbus address 485, default value 60. Settings, Free cooling."
    },
    {
      "address": 486,
      "count": 1,
      "name": "SAF output when free cooling and frequency fan: 0=the output is normal speed",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolSA FOutput, EXOL type R, Modbus address 486, default value 0. Settings, Free cooling."
    },
    {
      "address": 487,
      "count": 1,
      "name": "EAF output when free cooling and frequency fan: 0=The output is normal speed",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW",
      "description": "Signal VentSettings.Cor_NightCoolEA FOutput, EXOL type R, Modbus address 487, default value 0. Settings, free cooling."
    }
  ],
  "combined_registers": [],
  "notes": "Source: Regin “Corrigo E Ventilation – List of network variables for EXOline and Modbus communication”, revision 13/14 (October 2013, software revision 3.2), vendor-hosted at https://www.regincontrols.com/globalassets/pimmediafiles/documents/corrigo_e_ventilation_variables_for_exoline_and_modbus_3.2_manu_en.pdf, chapter 1-6; serial settings and defaults from the Corrigo E Ventilation manual, revision Q, §16.28.1 (https://www.regincontrols.com/globalassets/pimmediafiles/documents/corrigo_e_ventilation_3.2_manu_en.pdf): Modbus address 1, 9600 bps, parity none, one stop bit, 8 data bits, RTU over RS-485 (only one stop bit can be used). Chapter 1 of the variable list states the Modbus type per signal (1 coil, 2 input status, 3 holding register, 4 input register), that Real signals carry scale factor 10, time-setting signals 100 and air-flow signals 1, and that a maximum of 47 registers can be read in one message. Addresses are the document's Modbus addresses, stored unchanged (zero_based). Real signals are Int16 with scale 0.1 (the 32-bit EXOL 'Real' becomes a 16-bit scaled integer on Modbus); Integer is Int16, Index and Logic are UInt16. Signals whose description neither states scale factor 1 nor rules out the time/air-flow scale exception (timer schedules, fan run times, air-flow setpoints without a stated scale) are left out rather than guessed; counted against the document's own tables that is 272 time-channel rows (TimeDp/TimeHp), 21 further settings rows (the Curve1_X2/Y2 points, the PID I/ITi/P gains, night cool and recycle settings) and one alarm-status row (input register 84). Duplicate rows the document prints twice for one address (for example the alarm-acknowledge coil 3) are listed once; the 20 Cor_DIReserved digital inputs and the 7 Cor_ReservedL coils the document labels 'Not used' are left out."
}