  "spec_version": 1,
  "slug": "evvo-string-inverters",
  "manufacturer": "EVVO",
  "model": "EVVO PV grid-connected string inverters (EVVO V4 Modbus protocol, 36-110 kW class)",
  "category": "Solar inverter",
  "supplier_url": "https://evvosolar.com/",
  "default_configuration": {
    "protocol": "modbus_rtu",
    "unit_id": 1,
    "addressing": "zero_based",
    "byte_order": "BigEndian",
    "word_order": "LowFirst",
    "native_interface": "rs485",
    "serial": {
      "baud_rate": 9600,
      "parity": "None",
      "data_bits": 8,
      "stop_bits": 1
    }
  },
  "coils": [],
  "discrete_inputs": [],
  "input_registers": [],
  "holding_registers": [
    {
      "address": 40000,
      "count": 2,
      "name": "Date and time setting",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40002,
      "count": 1,
      "name": "Reactive power regulation mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40003,
      "count": 1,
      "name": "Power factor regulation",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.0001,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40004,
      "count": 1,
      "name": "Reactive power kVar regulation",
      "data_type": "Int16",
      "units": "kvar",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40005,
      "count": 1,
      "name": "Reactive power ratio regulation",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40011,
      "count": 1,
      "name": "Active power regulation mode",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40012,
      "count": 1,
      "name": "Active power actual regulation",
      "data_type": "Int16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40013,
      "count": 1,
      "name": "Active power ratio regulation",
      "data_type": "Int16",
      "units": "%",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40200,
      "count": 1,
      "name": "Startup command",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40201,
      "count": 1,
      "name": "Shutdown command",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40202,
      "count": 1,
      "name": "Reset command",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40203,
      "count": 1,
      "name": "SVG startup",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW"
    },
    {
      "address": 40500,
      "count": 1,
      "name": "MPPT1 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40501,
      "count": 1,
      "name": "MPPT2 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40502,
      "count": 1,
      "name": "MPPT3 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40503,
      "count": 1,
      "name": "MPPT4 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40504,
      "count": 1,
      "name": "MPPT5 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40505,
      "count": 1,
      "name": "MPPT6 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40506,
      "count": 1,
      "name": "MPPT7 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40507,
      "count": 1,
      "name": "MPPT8 input voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40508,
      "count": 1,
      "name": "String 01 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40509,
      "count": 1,
      "name": "String 02 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40510,
      "count": 1,
      "name": "String 03 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40511,
      "count": 1,
      "name": "String 04 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40512,
      "count": 1,
      "name": "String 05 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40513,
      "count": 1,
      "name": "String 06 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40514,
      "count": 1,
      "name": "String 07 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40515,
      "count": 1,
      "name": "String 08 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40516,
      "count": 1,
      "name": "String 09 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40517,
      "count": 1,
      "name": "String 10 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40518,
      "count": 1,
      "name": "String 11 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40519,
      "count": 1,
      "name": "String 12 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40520,
      "count": 1,
      "name": "String 13 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40521,
      "count": 1,
      "name": "String 14 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40522,
      "count": 1,
      "name": "String 15 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40523,
      "count": 1,
      "name": "String 16 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40524,
      "count": 1,
      "name": "MPPT1 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40525,
      "count": 1,
      "name": "MPPT2 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40526,
      "count": 1,
      "name": "MPPT3 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40527,
      "count": 1,
      "name": "MPPT4 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40528,
      "count": 1,
      "name": "MPPT5 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40529,
      "count": 1,
      "name": "MPPT6 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40530,
      "count": 1,
      "name": "MPPT7 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40531,
      "count": 1,
      "name": "MPPT8 input power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40532,
      "count": 1,
      "name": "Power grid line AB voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40533,
      "count": 1,
      "name": "Power grid line BC voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40534,
      "count": 1,
      "name": "Power grid line AC voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40535,
      "count": 1,
      "name": "Grid A-phase current (Ia)",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40536,
      "count": 1,
      "name": "Grid B-phase current (Ib)",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40537,
      "count": 1,
      "name": "Grid C-phase current (Ic)",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40538,
      "count": 1,
      "name": "Grid frequency (the document prints the name \"Grid power\" with unit Hz)",
      "data_type": "Int16",
      "units": "Hz",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40539,
      "count": 1,
      "name": "AC active power",
      "data_type": "Int16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40540,
      "count": 1,
      "name": "AC reactive power",
      "data_type": "Int16",
      "units": "kvar",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40541,
      "count": 1,
      "name": "DC input power",
      "data_type": "Int16",
      "units": "kW",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40542,
      "count": 1,
      "name": "Inverter efficiency",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40543,
      "count": 1,
      "name": "Power factor",
      "data_type": "Int16",
      "units": "",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40544,
      "count": 1,
      "name": "Internal machine temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40545,
      "count": 1,
      "name": "Insulation resistance",
      "data_type": "UInt16",
      "units": "kΩ",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40546,
      "count": 1,
      "name": "Inverter switch status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40547,
      "count": 1,
      "name": "Inverter status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40548,
      "count": 2,
      "name": "Energy genereated for the day",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40550,
      "count": 2,
      "name": "Total generated energy",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40552,
      "count": 2,
      "name": "CO2 emission reduction amount",
      "data_type": "UInt32",
      "units": "kg",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40554,
      "count": 1,
      "name": "Daily running time",
      "data_type": "UInt16",
      "units": "h",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Hours; the document prints the unit as Hour"
    },
    {
      "address": 40555,
      "count": 2,
      "name": "Total running time",
      "data_type": "UInt32",
      "units": "h",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R",
      "description": "Hours; the document prints the unit as Hour"
    },
    {
      "address": 40557,
      "count": 2,
      "name": "Inverter startup time",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40559,
      "count": 2,
      "name": "Inverter shutdown time",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40561,
      "count": 1,
      "name": "Inverter fault word 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40562,
      "count": 1,
      "name": "Inverter fault word 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40563,
      "count": 1,
      "name": "Inverter fault word 3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40564,
      "count": 1,
      "name": "Inverter fault word 4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40565,
      "count": 1,
      "name": "Inverter fault word 5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40566,
      "count": 1,
      "name": "Inverter fault word 6",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40567,
      "count": 1,
      "name": "Inverter fault word 7",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40568,
      "count": 1,
      "name": "Inverter fault word 8",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40569,
      "count": 1,
      "name": "Inverter alarm word 1",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40570,
      "count": 1,
      "name": "Inverter alarm word 2",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40571,
      "count": 1,
      "name": "Inverter alarm word 3",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40572,
      "count": 1,
      "name": "Inverter alarm word 4",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40573,
      "count": 1,
      "name": "Inverter alarm word 5",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40574,
      "count": 1,
      "name": "Inverter alarm word 6",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40575,
      "count": 1,
      "name": "Inverter alarm word 7",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40576,
      "count": 1,
      "name": "Inverter alarm word 8",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40577,
      "count": 1,
      "name": "PID status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40578,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40579,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40580,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40581,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40582,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40583,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40584,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40585,
      "count": 1,
      "name": "Running status of the inverter",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40586,
      "count": 1,
      "name": "Busbar voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40587,
      "count": 1,
      "name": "Positive bus voltage",
      "data_type": "Int16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40588,
      "count": 1,
      "name": "String 17 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40589,
      "count": 1,
      "name": "String 18 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40590,
      "count": 1,
      "name": "String 19 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40591,
      "count": 1,
      "name": "String 20 input current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40592,
      "count": 1,
      "name": "Fault code",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40593,
      "count": 1,
      "name": "Alarm code",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40594,
      "count": 1,
      "name": "AC apparent power",
      "data_type": "Int16",
      "units": "kVA",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40631,
      "count": 2,
      "name": "Software version _DC_AC",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40633,
      "count": 2,
      "name": "Software version _DC_DC",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40635,
      "count": 2,
      "name": "Software version _FPGA",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40637,
      "count": 2,
      "name": "Parameter version _DC_AC",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40639,
      "count": 2,
      "name": "Software version_ bootloader",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40641,
      "count": 2,
      "name": "Communication protocol version",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40643,
      "count": 2,
      "name": "Parameter version _DC_DC",
      "data_type": "UInt32",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40646,
      "count": 1,
      "name": "Rated power",
      "data_type": "UInt16",
      "units": "kW",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 40647,
      "count": 1,
      "name": "Rated voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 42000,
      "count": 2,
      "name": "Countercurrent active power",
      "data_type": "Int32",
      "units": "kW",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 42002,
      "count": 2,
      "name": "Power taking active power of the grid",
      "data_type": "Int32",
      "units": "kW",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 42004,
      "count": 2,
      "name": "Loads consumed active power",
      "data_type": "Int32",
      "units": "kW",
      "scale_factor": 0.001,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 42006,
      "count": 2,
      "name": "Total backflow electricity",
      "data_type": "Int32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 42008,
      "count": 2,
      "name": "Total electricity taken from the grid",
      "data_type": "Int32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 42010,
      "count": 2,
      "name": "Total electricity consumed by the load",
      "data_type": "Int32",
      "units": "kWh",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    }
  ],
  "combined_registers": [],
  "notes": "Source: EVVO \"Communication Protocol of PV Grid-Connected String Inverters\" (EVVO V4 Modbus), V1.0, 2022-12-07, vendor-hosted at https://evvosolar.com/doc/Modbus/V4/36_110Modbus.pdf (SHA-256 4bdc090129af7fe3cd6fb4af43aa5341cfa62c478d64fa74f4707ac60a9b70e5). Section 2 gives the factory serial frame: 9600 bps (also settable to 38400/57600/115200), device address 1 (range 1-247), 1 start bit, 8 data bits, no parity, 1 stop bit. Section 3 reads with function code 0x03 (so every row is a holding register) and writes with 0x06/0x10; section 4.1 returns 32-bit values low word first, hence LowFirst; section 4.2 defines Gain as a divisor, so the stored factors are 1/gain. The printed addresses are wire addresses: section 8 reads \"register address 40500\" by sending 0x9E34 (= 40500) with function code 03, so the seed is zero-based and stores them unchanged. Seeded: the section 6.1 telemetry block 40500-40594 (MPPT and string inputs, grid and machine measurements, fault/alarm words, running status and energy counters), the 42000-42011 backflow counters, the section 6.2 remote-control commands 40200-40203, the section 6.3 remote-regulating block 40000-40013 and the section 6.4 device-characteristic block 40631-40647; 40000-40203 are writable and marked RW. Register 40538 keeps the document's own wording, which names it \"Grid power\" while giving the unit Hz: it is the grid frequency, and the row says so. Units follow the document apart from spellings normalised to the library (HZ/Hz, kVar/kvar, Hour/h). Not seeded: the serial number (40601, 30 character registers, no stated encoding), the unnamed \"Data\" filler rows (40595-40599, 40600, 40645, 40648-40650), the rows its page breaks repeat (40562/40564/40568/40585) and the section 7 APP protocol block (1080, 1082, 30000-30130, 31112/31114, 32000-32005), the vendor's app-setting surface. EVVO inverters are Hopewind OEM hardware: this is the EVVO-branded map, and no separate Hopewind seed was added for the same platform."
}