  "holding_registers": [
    {
      "address": 0,
      "count": 1,
      "name": "Cell 1 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 1,
      "count": 1,
      "name": "Cell 2 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 2,
      "count": 1,
      "name": "Cell 3 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 3,
      "count": 1,
      "name": "Cell 4 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 4,
      "count": 1,
      "name": "Cell 5 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 5,
      "count": 1,
      "name": "Cell 6 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 6,
      "count": 1,
      "name": "Cell 7 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 7,
      "count": 1,
      "name": "Cell 8 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 8,
      "count": 1,
      "name": "Cell 9 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 9,
      "count": 1,
      "name": "Cell 10 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 10,
      "count": 1,
      "name": "Cell 11 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 11,
      "count": 1,
      "name": "Cell 12 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 12,
      "count": 1,
      "name": "Cell 13 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 13,
      "count": 1,
      "name": "Cell 14 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 14,
      "count": 1,
      "name": "Cell 15 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 15,
      "count": 1,
      "name": "Cell 16 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 16,
      "count": 1,
      "name": "Cell 17 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 17,
      "count": 1,
      "name": "Cell 18 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 18,
      "count": 1,
      "name": "Cell 19 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 19,
      "count": 1,
      "name": "Cell 20 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 20,
      "count": 1,
      "name": "Cell 21 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 21,
      "count": 1,
      "name": "Cell 22 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 22,
      "count": 1,
      "name": "Cell 23 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 23,
      "count": 1,
      "name": "Cell 24 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 24,
      "count": 1,
      "name": "Cell 25 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 25,
      "count": 1,
      "name": "Cell 26 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 26,
      "count": 1,
      "name": "Cell 27 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 27,
      "count": 1,
      "name": "Cell 28 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 28,
      "count": 1,
      "name": "Cell 29 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 29,
      "count": 1,
      "name": "Cell 30 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 30,
      "count": 1,
      "name": "Cell 31 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 31,
      "count": 1,
      "name": "Cell 32 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 32,
      "count": 1,
      "name": "Cell 33 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 33,
      "count": 1,
      "name": "Cell 34 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 34,
      "count": 1,
      "name": "Cell 35 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 35,
      "count": 1,
      "name": "Cell 36 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 36,
      "count": 1,
      "name": "Cell 37 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 37,
      "count": 1,
      "name": "Cell 38 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 38,
      "count": 1,
      "name": "Cell 39 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 39,
      "count": 1,
      "name": "Cell 40 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 40,
      "count": 1,
      "name": "Cell 41 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 41,
      "count": 1,
      "name": "Cell 42 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 42,
      "count": 1,
      "name": "Cell 43 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 43,
      "count": 1,
      "name": "Cell 44 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 44,
      "count": 1,
      "name": "Cell 45 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 45,
      "count": 1,
      "name": "Cell 46 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 46,
      "count": 1,
      "name": "Cell 47 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 47,
      "count": 1,
      "name": "Cell 48 voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document reserves 0x0000-0x002F for the cell chain of up to 48 cells and prints values for cells 1-8 (0x0000-0x0007)."
    },
    {
      "address": 48,
      "count": 1,
      "name": "Temperature sensor 1",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R",
      "description": "The document stores temperatures with a +40 offset."
    },
    {
      "address": 49,
      "count": 1,
      "name": "Temperature sensor 2",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R",
      "description": "The document stores temperatures with a +40 offset."
    },
    {
      "address": 50,
      "count": 1,
      "name": "Temperature sensor 3",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R",
      "description": "The document stores temperatures with a +40 offset."
    },
    {
      "address": 51,
      "count": 1,
      "name": "Temperature sensor 4",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R",
      "description": "The document stores temperatures with a +40 offset."
    },
    {
      "address": 56,
      "count": 1,
      "name": "Pack voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 57,
      "count": 1,
      "name": "Pack current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": -3000,
      "access": "R",
      "description": "The document stores current with a +30000 offset in 0.1 A units, so an idle pack reads 3000 after scaling. UInt16 because the offset encoding is unsigned: the full documented range (0-65535 raw) maps to -3000.0 to +3553.5 A, which a signed 16-bit row would truncate."
    },
    {
      "address": 58,
      "count": 1,
      "name": "State of charge",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 60,
      "count": 1,
      "name": "Cell count",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 61,
      "count": 1,
      "name": "Temperature sensor count",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 62,
      "count": 1,
      "name": "Maximum cell voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 63,
      "count": 1,
      "name": "Number of the maximum cell",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Cell number, 1-based as the document prints it."
    },
    {
      "address": 64,
      "count": 1,
      "name": "Minimum cell voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 65,
      "count": 1,
      "name": "Number of the minimum cell",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 66,
      "count": 1,
      "name": "Cell voltage spread",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 67,
      "count": 1,
      "name": "Maximum temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R"
    },
    {
      "address": 68,
      "count": 1,
      "name": "Sensor number of the maximum temperature",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 69,
      "count": 1,
      "name": "Minimum temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R"
    },
    {
      "address": 70,
      "count": 1,
      "name": "Sensor number of the minimum temperature",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 71,
      "count": 1,
      "name": "Temperature spread",
      "data_type": "UInt16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 72,
      "count": 1,
      "name": "Pack state",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 idle, 1 charging, 2 discharging, as the document prints."
    },
    {
      "address": 75,
      "count": 1,
      "name": "Remaining capacity",
      "data_type": "UInt16",
      "units": "Ah",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 77,
      "count": 1,
      "name": "Balancing in progress",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document prints 2 = yes."
    },
    {
      "address": 78,
      "count": 1,
      "name": "Balancer current",
      "data_type": "UInt16",
      "units": "mA",
      "scale_factor": 1,
      "offset": -30000,
      "access": "R",
      "description": "The document stores this current with a +30000 offset, so the encoding is unsigned and the row is UInt16."
    },
    {
      "address": 79,
      "count": 1,
      "name": "Balancing cell mask",
      "data_type": "Hex",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bit mask; the document prints that cell N is 256 << (N-1)."
    },
    {
      "address": 82,
      "count": 1,
      "name": "Charge MOSFET position",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0-1, as the document prints."
    },
    {
      "address": 83,
      "count": 1,
      "name": "Discharge MOSFET position",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0-1, as the document prints."
    },
    {
      "address": 87,
      "count": 1,
      "name": "Mean cell voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 88,
      "count": 1,
      "name": "Pack power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 90,
      "count": 1,
      "name": "MOSFET temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R"
    },
    {
      "address": 114,
      "count": 1,
      "name": "Forced-closure state",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document prints 0 or 4."
    },
    {
      "address": 257,
      "count": 1,
      "name": "Cell count setting",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 262,
      "count": 1,
      "name": "Temperature sensor count setting",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 276,
      "count": 1,
      "name": "Nominal cell voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 277,
      "count": 1,
      "name": "Sleep timeout",
      "data_type": "UInt16",
      "units": "s",
      "scale_factor": 10,
      "offset": 0,
      "access": "R",
      "description": "Unit 10 s, as the document prints, and 65535 means never sleep. Seeded read-only: the document prints no valid range for the value, only the unit and the never-sleep code."
    },
    {
      "address": 278,
      "count": 1,
      "name": "State of charge counter",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "The document prints this as writable (writing it calibrates the SOC counter, 0.1 %). Seeded read-only: a wrong value misreports the pack's state of charge."
    },
    {
      "address": 279,
      "count": 1,
      "name": "Balancer current setting",
      "data_type": "UInt16",
      "units": "mA",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document prints this as a writable balancer current. Seeded read-only: an over-high setting overworks the balancer."
    },
    {
      "address": 281,
      "count": 1,
      "name": "Balancing enabled",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0-1, as the document prints (1 = balancing enabled, 0 = disabled). Read-only here: the source is a community reverse-engineering that prints the values but no operating range, so no write is offered."
    },
    {
      "address": 282,
      "count": 1,
      "name": "Balance start voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document prints 0x011A as writable and says it is mirrored at 0x022A. Seeded read-only because a wrong start voltage changes how the pack is balanced."
    },
    {
      "address": 283,
      "count": 1,
      "name": "Balance start voltage difference",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document prints 0x011B as writable. Seeded read-only because a wrong trigger difference changes how the pack is balanced."
    },
    {
      "address": 289,
      "count": 1,
      "name": "Charge switch permission",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0-1, as the document prints. Seeded read-only: the document does not print what writing 0 does to the charge switch, and taking the charge path out of service is the one effect it could have."
    },
    {
      "address": 290,
      "count": 1,
      "name": "Discharge switch permission",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0-1, as the document prints. Seeded read-only: the document does not print what writing 0 does to the discharge switch, and taking the discharge path out of service is the one effect it could have."
    },
    {
      "address": 354,
      "count": 1,
      "name": "SOC thresholds",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R",
      "description": "The document names one register here; the per-level layout is its four-register threshold structure."
    },
    {
      "address": 358,
      "count": 1,
      "name": "MOSFET over-temperature threshold",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": -40,
      "access": "R"
    },
    {
      "address": 366,
      "count": 1,
      "name": "Short-circuit trip current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 367,
      "count": 1,
      "name": "Current zero-drift dead band",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.01,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 376,
      "count": 7,
      "name": "Software version string",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "ASCII, 7 registers, as the document prints."
    },
    {
      "address": 383,
      "count": 7,
      "name": "Hardware version string",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "ASCII, 7 registers."
    },
    {
      "address": 397,
      "count": 7,
      "name": "Serial number",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "ASCII, 7 registers."
    },
    {
      "address": 409,
      "count": 7,
      "name": "Battery code",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "ASCII, 7 registers."
    },
    {
      "address": 507,
      "count": 1,
      "name": "Balance stop voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The document prints 0x01FB as writable. Seeded read-only because a wrong stop voltage changes how the pack is balanced."
    },
    {
      "address": 551,
      "count": 1,
      "name": "SOC calibration: 0 % cell voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 553,
      "count": 1,
      "name": "SOC calibration: 100 % cell voltage",
      "data_type": "UInt16",
      "units": "mV",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    }
  ],
  "combined_registers": [],
  "notes": "SECONDARY SOURCE (community map): \"DALY smart BMS - UART protocol reference\", github.com/antonkostryukov/daly-bms-protocol commit 6560d66c7b056cf528f5dc621691c3e80baa5f26 (2026-09-13), README.md SHA-256 4adf4b9616238ebe0e7c6cc36ec77229586dc91124bfb19426d8ec6990d07ae5, read 2026-11-23. Reverse-engineered from two boards (R24TK1A-8S100A, R24TM) and cross-checked against the vendor apps; maps differ by model and firmware, so every row is secondary. Framing printed: 3.3 V logic, 9600 8N1, CRC16, 0x03 read, 0x06/0x10 write. Unit 129 (0x81) is cited: the board answers 0x81 and ignores 0x51 and 0x01; the compact map on 0xD2 is not seeded (one unit per seed). Live data and settings are holding registers because the source reads them with 0x03. Offsets as printed: temperatures +40 (offset -40); pack and balancer current +30000, so both rows are UInt16, since the offset encoding is unsigned and a signed row would truncate the range. Balance mask cell N is 256 << (N-1). No word order is printed for the 32-bit pairs, so uptimes, capacities, charged/discharged totals and the packed clock 0x0061-0x0063 are left out. Writes: none: 0x0119 balancing enabled is readable only, because the source prints its values but no operating range. Settings kept read-only: sleep timeout 0x0115 (no valid range printed), charge and discharge switch permissions 0x0121/0x0122 (the source does not print what writing 0 does to the switch), SOC counter 0x0116, balancer current 0x0117, balance start voltage and delta 0x011A/0x011B, balance stop voltage 0x01FB. Also left out: clock 0x0123-0x0125, password 0x0126-0x0128, production date, forced-closure arm 0x012E, the five-register current blocks 0x0140/0x0145 and the four-register threshold blocks 0x014A-0x015E (the source names each block, not its levels); the single named rows 0x0162, 0x0166, 0x016E and 0x016F are seeded. The source warns that a wrong write can silently corrupt a neighbouring threshold and that 0x00F0 reboots the board."
}