  "spec_version": 1,
  "slug": "bluetti-balco-260-500",
  "manufacturer": "BLUETTI",
  "model": "Balco 260 / Balco 500 balcony storage",
  "category": "Home battery",
  "supplier_url": "https://www.bluetti.com/products/balco-260",
  "default_configuration": {
    "protocol": "modbus_tcp",
    "port": 502,
    "unit_id": 1,
    "addressing": "zero_based",
    "byte_order": "BigEndian",
    "word_order": "LowFirst"
  },
  "coils": [],
  "discrete_inputs": [],
  "input_registers": [],
  "holding_registers": [
    {
      "address": 50001,
      "count": 1,
      "name": "Number of Inverters",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50002,
      "count": 2,
      "name": "AC Load Power (Total)",
      "data_type": "UInt32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50004,
      "count": 2,
      "name": "PV Power (Total)",
      "data_type": "UInt32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50006,
      "count": 2,
      "name": "Grid Power (Total)",
      "data_type": "Int32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signed 32-bit value, as the sheet's type column is int. The sheet prints no sign convention for the totals row, and the vendor repository's issue #12 reports the value as the sum of the three phase magnitudes, so import and export cannot be told apart in it."
    },
    {
      "address": 50008,
      "count": 2,
      "name": "Inverter Power (Total)",
      "data_type": "Int32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Signed 32-bit value, as the sheet's type column is int, 2 registers wide. On a live Balco 260 the pair 50008-50009 reads [64336, 0xFFFF], which is -1200 W low word first (bluetti-community/bluetti-modbus test suite, bluetti-registers#20), matching the charging power computed from pack voltage and current at the same moment."
    },
    {
      "address": 50010,
      "count": 2,
      "name": "PV to AC Load Power",
      "data_type": "UInt32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50012,
      "count": 2,
      "name": "AC Load Energy (Total)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50014,
      "count": 2,
      "name": "PV Charging Energy (Total)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50016,
      "count": 2,
      "name": "Grid Charging Energy (Total)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50018,
      "count": 2,
      "name": "Feed-in Grid Energy",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50020,
      "count": 2,
      "name": "PV to AC Load Energy",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50022,
      "count": 1,
      "name": "Inverter Operating Status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging, 6 = inverter fault, 7 = abnormal off-grid. Values as printed in the vendor sheet."
    },
    {
      "address": 50200,
      "count": 6,
      "name": "Inverter Type",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50214,
      "count": 1,
      "name": "Grid Access Frequency",
      "data_type": "UInt16",
      "units": "Hz",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50215,
      "count": 2,
      "name": "Grid Charging Power (Single)",
      "data_type": "Int32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50217,
      "count": 2,
      "name": "AC Load Power (Single)",
      "data_type": "UInt32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50219,
      "count": 2,
      "name": "PV Charging Power (Single)",
      "data_type": "UInt32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50221,
      "count": 2,
      "name": "PV to AC Load Power (Single)",
      "data_type": "UInt32",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50223,
      "count": 2,
      "name": "Grid Charging Energy (Single)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50225,
      "count": 2,
      "name": "Feed-in Grid Energy (Single)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50227,
      "count": 2,
      "name": "AC Load Energy (Single)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50229,
      "count": 2,
      "name": "PV Charging Energy (Single)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50231,
      "count": 2,
      "name": "PV to AC Load Energy (Single)",
      "data_type": "UInt32",
      "units": "kWh",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50234,
      "count": 1,
      "name": "System Phase Number",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50236,
      "count": 1,
      "name": "Grid1 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50237,
      "count": 1,
      "name": "Grid1 Current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50239,
      "count": 1,
      "name": "Grid2 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50240,
      "count": 1,
      "name": "Grid2 Current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50242,
      "count": 1,
      "name": "Grid3 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50243,
      "count": 1,
      "name": "Grid3 Current",
      "data_type": "Int16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50244,
      "count": 1,
      "name": "AC System Phase Number",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50245,
      "count": 1,
      "name": "AC Load1 Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50246,
      "count": 1,
      "name": "AC Load1 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50247,
      "count": 1,
      "name": "AC Load1 Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50248,
      "count": 1,
      "name": "AC Load2 Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50249,
      "count": 1,
      "name": "AC Load2 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50250,
      "count": 1,
      "name": "AC Load2 Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50251,
      "count": 1,
      "name": "AC Load3 Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50252,
      "count": 1,
      "name": "AC Load3 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50253,
      "count": 1,
      "name": "AC Load3 Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50254,
      "count": 1,
      "name": "Inverter System Phase Number",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50255,
      "count": 1,
      "name": "Inverter1 Operation Status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging."
    },
    {
      "address": 50256,
      "count": 1,
      "name": "Inverter1 Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50257,
      "count": 1,
      "name": "Inverter1 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50258,
      "count": 1,
      "name": "Inverter1 Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50259,
      "count": 1,
      "name": "Inverter2 Operation Status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging."
    },
    {
      "address": 50260,
      "count": 1,
      "name": "Inverter2 Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50261,
      "count": 1,
      "name": "Inverter2 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50262,
      "count": 1,
      "name": "Inverter2 Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50263,
      "count": 1,
      "name": "Inverter3 Operation Status",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = stop, 1 = off-grid operation, 2 = grid-connected load, 3 = grid-connected operation, 4 = grid-connected charging, 5 = grid-connected discharging."
    },
    {
      "address": 50264,
      "count": 1,
      "name": "Inverter3 Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50265,
      "count": 1,
      "name": "Inverter3 Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50266,
      "count": 1,
      "name": "Inverter3 Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50267,
      "count": 1,
      "name": "PV Total Number",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Bit 0-3 = number of DC PV inputs, bit 4-7 = number of AC PV inputs."
    },
    {
      "address": 50268,
      "count": 1,
      "name": "PV1 Type",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them"
    },
    {
      "address": 50269,
      "count": 1,
      "name": "PV1 Input Power",
      "data_type": "UInt16",
      "units": "W",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50270,
      "count": 1,
      "name": "PV1 Input Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50271,
      "count": 1,
      "name": "PV1 Input Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 50272,
      "count": 1,
      "name": "PV2 Type",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. Only the inputs a model actually has are meaningful: a measured EP2000 reports two DC inputs and reads junk in the slots from PV3 up (vendor repository issue #12), so treat PV3 to PV5 as model-dependent on the BalcoXX family too."
    },
    {
      "address": 50276,
      "count": 1,
      "name": "PV3 Type",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. Only the inputs a model actually has are meaningful: a measured EP2000 reports two DC inputs and reads junk in the slots from PV3 up (vendor repository issue #12), so treat PV3 to PV5 as model-dependent on the BalcoXX family too."
    },
    {
      "address": 50280,
      "count": 1,
      "name": "PV4 Type",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. Only the inputs a model actually has are meaningful: a measured EP2000 reports two DC inputs and reads junk in the slots from PV3 up (vendor repository issue #12), so treat PV3 to PV5 as model-dependent on the BalcoXX family too."
    },
    {
      "address": 50284,
      "count": 1,
      "name": "PV5 Type",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "0 = reserve, 1 = CAR, 2 = adapter, 3 = other; 100 = DC PV and 101 = AC PV on the models that report them. Only the inputs a model actually has are meaningful: a measured EP2000 reports two DC inputs and reads junk in the slots from PV3 up (vendor repository issue #12), so treat PV3 to PV5 as model-dependent on the BalcoXX family too."
    },
    {
      "address": 51002,
      "count": 1,
      "name": "Total Pack Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51003,
      "count": 1,
      "name": "Total Pack Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51200,
      "count": 6,
      "name": "Pack Type",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51210,
      "count": 1,
      "name": "Total Pack Software Number",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51219,
      "count": 1,
      "name": "Pack Voltage",
      "data_type": "UInt16",
      "units": "V",
      "scale_factor": 0.1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51220,
      "count": 1,
      "name": "Pack Current",
      "data_type": "UInt16",
      "units": "A",
      "scale_factor": 0.1,
      "offset": -3000,
      "access": "R",
      "description": "The sheet types the pack current as unsigned, unlike the string-level current rows. BLUETTI support reports that the Balco 260 encodes it as the raw value minus 30000 at 0.1 A (quoted in the vendor repository's issue #12), which the offset applies; the sheet documents neither the offset nor a sign."
    },
    {
      "address": 51221,
      "count": 1,
      "name": "Pack SOC",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51222,
      "count": 1,
      "name": "Pack SOH",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51223,
      "count": 1,
      "name": "Pack Cycle Count",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51224,
      "count": 1,
      "name": "Pack Average Temperature",
      "data_type": "Int16",
      "units": "°C",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "The sheet gives -40 to 160. On an EP2000 the same row reads degrees Celsius plus 40 (measured: raw 58 while the packs were at 18 °C, vendor repository issues #12 and #145), and this sheet's range fits that encoding, but no Balco has been measured and the Balco 500 community entry reads the row as plain °C. Seeded without an offset until one is measured."
    },
    {
      "address": 51234,
      "count": 1,
      "name": "Pack Total Cell Count",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51235,
      "count": 1,
      "name": "Pack Total NTC Count",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51236,
      "count": 2,
      "name": "Pack Total Charging Energy",
      "data_type": "UInt32",
      "units": "Wh",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51238,
      "count": 2,
      "name": "Pack Total Discharging Energy",
      "data_type": "UInt32",
      "units": "Wh",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 51248,
      "count": 1,
      "name": "Pack Estimated Full Charge Time",
      "data_type": "UInt16",
      "units": "min",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Minutes. On measured EP2000 units this estimate and its discharge counterpart 51249 always read the same value, charging or discharging (vendor repository issue #12); no such reading exists for a Balco."
    },
    {
      "address": 51249,
      "count": 1,
      "name": "Pack Estimated Full Discharge Time",
      "data_type": "UInt16",
      "units": "min",
      "scale_factor": 1,
      "offset": 0,
      "access": "R",
      "description": "Minutes. Reads the same value as 51248 on measured EP2000 units."
    },
    {
      "address": 53001,
      "count": 6,
      "name": "IoT Model",
      "data_type": "Ascii",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "R"
    },
    {
      "address": 57001,
      "count": 1,
      "name": "AC load output switch",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0 = off, 1 = on."
    },
    {
      "address": 57009,
      "count": 1,
      "name": "AC grid charging switch",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0 = off, 1 = on."
    },
    {
      "address": 57010,
      "count": 1,
      "name": "AC grid feed-in switch",
      "data_type": "UInt16",
      "units": "",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "0 = off, 1 = on."
    },
    {
      "address": 57016,
      "count": 1,
      "name": "Battery empty SOC threshold",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Discharging stops at this state of charge. The sheet prints 0 to 100, in percent, as the valid range."
    },
    {
      "address": 57017,
      "count": 1,
      "name": "Battery full SOC threshold",
      "data_type": "UInt16",
      "units": "%",
      "scale_factor": 1,
      "offset": 0,
      "access": "RW",
      "description": "Charging stops at this state of charge. The sheet prints 0 to 100, in percent, as the valid range."
    }
  ],
  "combined_registers": [],
  "notes": "Register map from BLUETTI's open Modbus TCP list, bluetti-official/bluetti-modbus-tcp-slave at commit cee4c98e: doc/Bluetti-Open-Modbus-TCP-register-list.xlsx (SHA-256 aa7687c5be29c605d03aef1957b5f79ee52000debe564a4d1038d9efce0a1371), sheet \"BalcoXX\", retrieved 2026-11-23. Its README gives the transport: Modbus TCP slave, slave address 1 by default, port set on its web page (502 in the example), Modbus TCP enabled there first; the Overview adds that address 250 is the aggregate unit. Function 3 at the sheet's wire addresses; its unit column is the scale. 32-bit values are LITTLE word first: the Overview states \"Register Data principle: Little-end storage; Modbus Protocol transmission principle: Big-end transmission\", and bluetti-community/bluetti-modbus, the library Home Assistant reads these registers with, decodes multi-word values with word_order=\"little\" - its real-hardware test (bluetti-registers#20) reads a live Balco 260's 50008-50009 as [64336, 0xFFFF] and decodes -1200 W, which only low-word-first gives. Left out, and why: 51001 and 51004-51008 (pack count, total SOC, SOH, status, two time estimates) answer only at unit ID 250 and read 0 at a device's own unit ID (Home Assistant core's bluetti_modbus const.py); also the warning and fault bit fields, the 64-bit serials, the version registers, the BMS protect/error/alarm words, self-consumption percent (sheet 0.01 against community 1), the int-or-uint per-phase grid power rows, and PV2-PV5 power, voltage and current, whose unit column carries the PV index while the vendor repository's issue #12 measures 1 W / 0.1 V / 0.1 A like PV1. Cross-checked against bluetti-community/bluetti-registers at 3f0707a6 (balco260.json, balco500.json): addresses, widths and access agree. Home Assistant core's bluetti_modbus names only the Balco 260 as tested, so the 500 rests on the vendor sheet and those community files. Five write registers are seeded, each with its valid values in its description."
}